Calibration of PM-355 nuclear track detectors;: comparison of track diameter diagrams with track depth characteristics

被引:10
|
作者
Szydlowski, A [1 ]
Sartowska, B
Banaszak, A
Choinski, J
Fijal, I
Jaskóla, M
Korman, A
Sadowski, MJ
机构
[1] Andrzej Soltan Inst Nucl Studies IPJ, PL-05400 Otwock, Poland
[2] Inst Nucl Chem & Technol, PL-03195 Warsaw, Poland
[3] Warsaw Univ, Heavy Ion Lab, PL-02097 Warsaw, Poland
关键词
PM-355; nuclear track detectors; track diameters;
D O I
10.1016/j.radmeas.2005.03.021
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The calibration diagrams, i.e. track diameters and track depths versus ion energy and etching time, as obtained for PM-355 track detector irradiated with He-ions are presented. The both detector characteristics are compared. The track etch rate is determined by two methods, as a function of the etch pit depth and the ion energy loss. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:401 / 403
页数:3
相关论文
共 50 条
  • [21] Color changes in gamma- and electron-beam-irradiated PM-355 nuclear track detector
    Nouh, S. A.
    Bahareth, Radiyah A.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2012, 167 (02): : 111 - 119
  • [22] ALPHA-PARTICLE SPECTROMETRY WITH A NEW POLYMERIC TRACK DETECTOR (PM-355)
    ABDEIMONEIM, AM
    ABDELNABY, A
    ELAKKAD, FA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (02): : 235 - 238
  • [23] TRACK-DIAMETER KINETICS IN DIELECTRIC TRACK DETECTORS
    SOMOGYI, G
    SZALAY, SA
    NUCLEAR INSTRUMENTS & METHODS, 1973, 109 (02): : 211 - 232
  • [24] Measurements of energetic ions emitted from laser produced plasma by means of solid state nuclear track detectors of the PM-355 type
    Szydlowski, A
    Badziak, J
    Parys, P
    Wolowski, J
    Woryna, E
    Jungwirth, K
    Kralikova, B
    Krasa, J
    Laska, L
    Pfeifer, M
    Rohlena, K
    Skala, J
    Ullschmied, J
    Boody, FD
    Gammino, S
    Torrisi, L
    PLASMA PHYSICS AND CONTROLLED FUSION, 2003, 45 (08) : 1417 - 1422
  • [25] Influence of alpha irradiation on pre and post solar exposed PM-355 polymeric nuclear track detector sheets
    Alsalhi, M. S.
    Baig, M. R.
    Alfaramawi, K.
    Alrasheedi, Mariam G.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 130 : 451 - 458
  • [26] Track etching characteristics of glass track detectors
    Randhawa, GS
    Virk, HS
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (03) : 351 - 354
  • [27] Detection characteristics of PM-355 solid-state nuclear track detector for normal incident light ions within MeV energies
    Szydlowski, A
    Sadowski, M
    Czyzewski, T
    Jaskóla, M
    Korman, A
    Fijal, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 171 (03): : 379 - 386
  • [28] Comparison of responses of LR-115A, CR-39 and PM-355 track detectors to pulsed low-energy proton streams
    Malinowski, K
    Skladnik-Sadowska, E
    Sadowski, MJ
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 371 - 374
  • [29] New method for internal calibration of nuclear track detectors
    Oda, K.
    Csige, I.
    Henke, R.P.
    Benton, E.V.
    Nuclear Tracks and Radiation Measurements, 1992, 20 (03): : 505 - 510
  • [30] A NEW METHOD FOR INTERNAL CALIBRATION OF NUCLEAR TRACK DETECTORS
    ODA, K
    CSIGE, I
    HENKE, RP
    BENTON, EV
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (03): : 505 - 510