Investigation of hospital indoor air quality for the presence of SARS-Cov-2

被引:29
|
作者
Masoumbeigi, Hossein [1 ]
Ghanizadeh, Ghader [2 ]
Yousefi Arfaei, Reza [3 ]
Heydari, Soleyman [4 ]
Goodarzi, Hassan [5 ]
Dorostkar Sari, Ruhollah [6 ]
Tat, Mehdi [6 ]
机构
[1] Baqiyatallah Univ Med Sci, Life Style Inst, Hlth Res Ctr, Tehran, Iran
[2] Baqiyatallah Univ Med Sci, Hlth Management Res Ctr, Tehran, Iran
[3] Baqiyatallah Univ Med Sci, Students Res Comm, Tehran, Iran
[4] Baqiyatallah Univ Med Sci, Trauma Res Ctr, Tehran, Iran
[5] Baqiyatallah Univ Med Sci, Emergency Deptment, Trauma Res Ctr, Tehran, Iran
[6] Baqiyatallah Univ Med Sci, Appl Virol Res Ctr, Tehran, Iran
关键词
Airborne; COVID-19; Hospital; Indoor air quality; SARS-Cov-2; CORONAVIRUSES;
D O I
10.1007/s40201-020-00543-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose Unidentified dynamics for the causative agent of COVID-19, SARS-Cov-2, led to the critical public health issue. Suspicion for the airborne potential of SARS-Cov-2 is an important problem for its transmission and relevant epidemics. This research investigated hospital indoor air quality to SARS-Cov-2 occurrence and determination its air born potential. Methods The site study was a referral hospital with 630 beds for admitting of COVID-19 patients. Air sampling was done (n = 31) on selected wards including Emergency 1, Emergency 2, bedridden (4-B, 10-D), ICU 2, ICU 3, CT-SCAN, and laundry. The average temperature and relative humidities were 22 +/- 1 degrees C and 43 percent respectively. All glass impinger used for sampling in which the sampling pumps capacities were 5 and 40 L.min(- 1). Sampling duration time was 20 and 15 minutes and 100 to 1000 L of air were gathered. All parts of the sampling equipment were completely disinfected by hot water, ethanol (70%), chlorine solution (1000 ppm), hot water (70 degrees C for 1 min) and washed with distilled water. The transmitting media (7 ml) was injected into impinger and residual of this media (2 ml) was sent to the virology laboratory within 2 hours and preserved on refrigerator < 4 degrees C. Analysis of samples was performed by RT-PCR and repeated for accuracy control. Results All of the samples were negative for SARS-Cov-2 occurrence. These results showed that SARS-Cov-2 had not airborne potential in this hospital. Conclusions Although SARS-Cov-2 similar to the SARS virus but, SARS-Cov-2 is not an airborne virus.
引用
收藏
页码:1259 / 1263
页数:5
相关论文
共 50 条
  • [31] Clearing the air of SARS-CoV-2
    Peplow, Mark
    CHEMICAL & ENGINEERING NEWS, 2021, 99 (09) : 16 - 19
  • [33] Evaluation of SARS-CoV-2 RNA Presence in Treated and Untreated Hospital Sewage
    Elahe Mobarak Qamsari
    Parisa Mohammadi
    Water, Air, & Soil Pollution, 2023, 234
  • [34] Evaluation of SARS-CoV-2 RNA Presence in Treated and Untreated Hospital Sewage
    Qamsari, Elahe Mobarak
    Mohammadi, Parisa
    WATER AIR AND SOIL POLLUTION, 2023, 234 (04):
  • [35] SARS-CoV-2 indoor air transmission is a threat that can he addressed with science
    Samet, Jonathan M.
    Burke, Thomas A.
    Lakdawala, Seema S.
    Lowe, John J.
    Marr, Linsey C.
    Prather, Kimberly A.
    Shelton-Davenport, Marilee
    Volckens, John
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (45)
  • [36] Detection of SARS-CoV-2 in the indoor air and surfaces of subway trains in Mashhad, Iran
    Mortazavi, Hanieh
    Sarkhosh, Maryam
    Najafpoor, Ali Asghar
    Azizi, Shohreh
    Tabatabaee, Seyed Saeed
    Davoudi, Mojtaba
    Miri, Hamid Heidarian
    Kamika, Ilunga
    BRAZILIAN JOURNAL OF MICROBIOLOGY, 2023, 54 (03) : 1865 - 1873
  • [37] May SARS-CoV-2 be prevented by an indoor air monitoring smart data service?
    Longo, Antonella
    Ardebili, Ali Aghazadeh
    Zappatore, Marco
    Mulla, Divya Pragna
    IEEE CONGRESS ON CYBERMATICS / 2021 IEEE INTERNATIONAL CONFERENCES ON INTERNET OF THINGS (ITHINGS) / IEEE GREEN COMPUTING AND COMMUNICATIONS (GREENCOM) / IEEE CYBER, PHYSICAL AND SOCIAL COMPUTING (CPSCOM) / IEEE SMART DATA (SMARTDATA), 2021, : 365 - 371
  • [38] Detection of SARS-CoV-2 in the indoor air and surfaces of subway trains in Mashhad, Iran
    Hanieh Mortazavi
    Maryam Sarkhosh
    Ali Asghar Najafpoor
    Shohreh Azizi
    Seyed Saeed Tabatabaee
    Mojtaba Davoudi
    Hamid Heidarian Miri
    Ilunga Kamika
    Brazilian Journal of Microbiology, 2023, 54 : 1865 - 1873
  • [39] Evidence of Air and Surface Contamination with SARS-CoV-2 in a Major Hospital in Portugal
    da Silva, Priscilla Gomes
    Goncalves, Jose
    Lopes, Ariana Isabel Brito
    Esteves, Nury Alves
    Bamba, Gustavo Emanuel Enes
    Nascimento, Maria Sao Jose
    Branco, Pedro T. B. S.
    Soares, Ruben R. G.
    Sousa, Sofia I. V.
    Mesquita, Joao R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (01)
  • [40] Detection of microorganisms in hospital air before and during the SARS-CoV-2 pandemic
    Zhao, Y-H
    Qu, H.
    Wang, Y.
    Wang, R.
    Zhao, Y.
    Huang, M-X
    Li, B.
    Zhu, W-M