Investigation of hospital indoor air quality for the presence of SARS-Cov-2

被引:29
|
作者
Masoumbeigi, Hossein [1 ]
Ghanizadeh, Ghader [2 ]
Yousefi Arfaei, Reza [3 ]
Heydari, Soleyman [4 ]
Goodarzi, Hassan [5 ]
Dorostkar Sari, Ruhollah [6 ]
Tat, Mehdi [6 ]
机构
[1] Baqiyatallah Univ Med Sci, Life Style Inst, Hlth Res Ctr, Tehran, Iran
[2] Baqiyatallah Univ Med Sci, Hlth Management Res Ctr, Tehran, Iran
[3] Baqiyatallah Univ Med Sci, Students Res Comm, Tehran, Iran
[4] Baqiyatallah Univ Med Sci, Trauma Res Ctr, Tehran, Iran
[5] Baqiyatallah Univ Med Sci, Emergency Deptment, Trauma Res Ctr, Tehran, Iran
[6] Baqiyatallah Univ Med Sci, Appl Virol Res Ctr, Tehran, Iran
关键词
Airborne; COVID-19; Hospital; Indoor air quality; SARS-Cov-2; CORONAVIRUSES;
D O I
10.1007/s40201-020-00543-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose Unidentified dynamics for the causative agent of COVID-19, SARS-Cov-2, led to the critical public health issue. Suspicion for the airborne potential of SARS-Cov-2 is an important problem for its transmission and relevant epidemics. This research investigated hospital indoor air quality to SARS-Cov-2 occurrence and determination its air born potential. Methods The site study was a referral hospital with 630 beds for admitting of COVID-19 patients. Air sampling was done (n = 31) on selected wards including Emergency 1, Emergency 2, bedridden (4-B, 10-D), ICU 2, ICU 3, CT-SCAN, and laundry. The average temperature and relative humidities were 22 +/- 1 degrees C and 43 percent respectively. All glass impinger used for sampling in which the sampling pumps capacities were 5 and 40 L.min(- 1). Sampling duration time was 20 and 15 minutes and 100 to 1000 L of air were gathered. All parts of the sampling equipment were completely disinfected by hot water, ethanol (70%), chlorine solution (1000 ppm), hot water (70 degrees C for 1 min) and washed with distilled water. The transmitting media (7 ml) was injected into impinger and residual of this media (2 ml) was sent to the virology laboratory within 2 hours and preserved on refrigerator < 4 degrees C. Analysis of samples was performed by RT-PCR and repeated for accuracy control. Results All of the samples were negative for SARS-Cov-2 occurrence. These results showed that SARS-Cov-2 had not airborne potential in this hospital. Conclusions Although SARS-Cov-2 similar to the SARS virus but, SARS-Cov-2 is not an airborne virus.
引用
收藏
页码:1259 / 1263
页数:5
相关论文
共 50 条
  • [21] SARS-CoV-2 in hospital indoor environments is predominantly non-infectious
    Krambrich, Janina
    Akaberi, Dario
    Ling, Jiaxin
    Hoffman, Tove
    Svensson, Lennart
    Hagbom, Marie
    Lundkvist, Ake
    VIROLOGY JOURNAL, 2021, 18 (01)
  • [22] Monitoring of indoor bioaerosol for the detection of SARS-CoV-2 in different hospital settings
    Tedeschini, Emma
    Pasqualini, Stefania
    Emiliani, Carla
    Marini, Ettore
    Valecchi, Alessandro
    Laoreti, Chiara
    Ministrini, Stefano
    Camilloni, Barbara
    Castronari, Roberto
    Patoia, Lucio
    Merante, Francesco
    Baglioni, Stefano
    De Robertis, Edoardo
    Pirro, Matteo
    Mencacci, Antonella
    Pasqualini, Leonella
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [23] SARS-CoV-2 in hospital indoor environments is predominantly non-infectious
    Janina Krambrich
    Dario Akaberi
    Jiaxin Ling
    Tove Hoffman
    Lennart Svensson
    Marie Hagbom
    Åke Lundkvist
    Virology Journal, 18
  • [24] SARS-CoV-2: a systematic review of indoor air sampling for virus detection
    João Tito Borges
    Liane Yuri Kondo Nakada
    Milena Guedes Maniero
    José Roberto Guimarães
    Environmental Science and Pollution Research, 2021, 28 : 40460 - 40473
  • [25] SARS-CoV-2: a systematic review of indoor air sampling for virus detection
    Borges, Joao Tito
    Kondo Nakada, Liane Yuri
    Maniero, Milena Guedes
    Guimaraes, Jose Roberto
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (30) : 40460 - 40473
  • [26] SARS-CoV-2 Presence in Cerumen
    Celik, Serdal
    Kalcioglu, M. Tayyar
    Esen, Fehim
    Hanege, Fatih Mehmet
    Cag, Yasemin
    Kocoglu, Esra
    ENT-EAR NOSE & THROAT JOURNAL, 2021, 100 (2_SUPPL) : 158S - 159S
  • [27] An algorithm for indoor SARS-CoV-2 transmission
    Maxin, Daniel
    Gannon, Spencer
    JOURNAL OF MIND AND MEDICAL SCIENCES, 2022, 9 (02): : 242 - +
  • [28] SARS-CoV-2: Sanitize a hospital
    De Caro, F.
    Moccia, G.
    Borrelli, A.
    Annecchiarico, A.
    Cioffi, G.
    Campanella, A.
    Motta, O.
    Caputo, V.
    Boccia, G.
    Capunzo, M.
    EUROPEAN JOURNAL OF PUBLIC HEALTH, 2020, 30 : V796 - V796
  • [29] Investigation of the Presence of SARS-CoV-2 in Aerosol After Dental Treatment
    Akin, Hakan
    Karabay, Oguz
    Toptan, Hande
    Furuncuoglu, Halit
    Kaya, Gurkan
    Akin, Emine Gulsah
    Koroglu, Mehmet
    INTERNATIONAL DENTAL JOURNAL, 2022, 72 (02) : 211 - 215
  • [30] Air filtration and SARS-CoV-2
    Nazarenko, Yevgen
    EPIDEMIOLOGY AND HEALTH, 2020, 42