Investigation of hospital indoor air quality for the presence of SARS-Cov-2

被引:29
|
作者
Masoumbeigi, Hossein [1 ]
Ghanizadeh, Ghader [2 ]
Yousefi Arfaei, Reza [3 ]
Heydari, Soleyman [4 ]
Goodarzi, Hassan [5 ]
Dorostkar Sari, Ruhollah [6 ]
Tat, Mehdi [6 ]
机构
[1] Baqiyatallah Univ Med Sci, Life Style Inst, Hlth Res Ctr, Tehran, Iran
[2] Baqiyatallah Univ Med Sci, Hlth Management Res Ctr, Tehran, Iran
[3] Baqiyatallah Univ Med Sci, Students Res Comm, Tehran, Iran
[4] Baqiyatallah Univ Med Sci, Trauma Res Ctr, Tehran, Iran
[5] Baqiyatallah Univ Med Sci, Emergency Deptment, Trauma Res Ctr, Tehran, Iran
[6] Baqiyatallah Univ Med Sci, Appl Virol Res Ctr, Tehran, Iran
关键词
Airborne; COVID-19; Hospital; Indoor air quality; SARS-Cov-2; CORONAVIRUSES;
D O I
10.1007/s40201-020-00543-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose Unidentified dynamics for the causative agent of COVID-19, SARS-Cov-2, led to the critical public health issue. Suspicion for the airborne potential of SARS-Cov-2 is an important problem for its transmission and relevant epidemics. This research investigated hospital indoor air quality to SARS-Cov-2 occurrence and determination its air born potential. Methods The site study was a referral hospital with 630 beds for admitting of COVID-19 patients. Air sampling was done (n = 31) on selected wards including Emergency 1, Emergency 2, bedridden (4-B, 10-D), ICU 2, ICU 3, CT-SCAN, and laundry. The average temperature and relative humidities were 22 +/- 1 degrees C and 43 percent respectively. All glass impinger used for sampling in which the sampling pumps capacities were 5 and 40 L.min(- 1). Sampling duration time was 20 and 15 minutes and 100 to 1000 L of air were gathered. All parts of the sampling equipment were completely disinfected by hot water, ethanol (70%), chlorine solution (1000 ppm), hot water (70 degrees C for 1 min) and washed with distilled water. The transmitting media (7 ml) was injected into impinger and residual of this media (2 ml) was sent to the virology laboratory within 2 hours and preserved on refrigerator < 4 degrees C. Analysis of samples was performed by RT-PCR and repeated for accuracy control. Results All of the samples were negative for SARS-Cov-2 occurrence. These results showed that SARS-Cov-2 had not airborne potential in this hospital. Conclusions Although SARS-Cov-2 similar to the SARS virus but, SARS-Cov-2 is not an airborne virus.
引用
收藏
页码:1259 / 1263
页数:5
相关论文
共 50 条
  • [1] Investigation of hospital indoor air quality for the presence of SARS-Cov-2
    Hossein Masoumbeigi
    Ghader Ghanizadeh
    Reza Yousefi Arfaei
    Soleyman Heydari
    Hassan Goodarzi
    Ruhollah Dorostkar Sari
    Mehdi Tat
    Journal of Environmental Health Science and Engineering, 2020, 18 : 1259 - 1263
  • [2] Hospital indoor air quality monitoring for the detection of SARS-CoV-2 (COVID-19) virus
    Kenarkoohi, Azra
    Noorimotlagh, Zahra
    Falahi, Shahab
    Amarloei, Ali
    Mirzaee, Seyyed Abbas
    Pakzad, Iraj
    Bastani, Elham
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 748
  • [3] Investigation of SARS-CoV-2 in hospital indoor air of COVID-19 patients' ward with impinger method
    Vosoughi, Mehdi
    Karami, Chiman
    Dargahi, Abdollah
    Jeddi, Farhad
    Jalali, Kamyar Mazloum
    Hadisi, Aidin
    Haghighi, Somayeh Biparva
    Dogahe, Hadi Peeri
    Noorimotlagh, Zahra
    Mirzaee, Seyyed Abbas
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (36) : 50480 - 50488
  • [4] Investigation of SARS-CoV-2 in hospital indoor air of COVID-19 patients’ ward with impinger method
    Mehdi Vosoughi
    Chiman Karami
    Abdollah Dargahi
    Farhad Jeddi
    Kamyar Mazloum Jalali
    Aidin Hadisi
    Somayeh Biparva Haghighi
    Hadi Peeri Dogahe
    Zahra Noorimotlagh
    Seyyed Abbas Mirzaee
    Environmental Science and Pollution Research, 2021, 28 : 50480 - 50488
  • [5] SARS-CoV-2 Reduction in Shared Indoor Air
    de mesquita, Jacob Bueno
    Sokas, Rosemary
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2022, 328 (21): : 2163 - 2163
  • [6] Reducing SARS-CoV-2 in Shared Indoor Air
    Dowell, Deborah
    Lindsley, William G.
    Brooks, John T.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2022, 328 (02): : 141 - 142
  • [7] Investigation of SARS-CoV-2 Genome in the Indoor Air and High-Touch Surfaces
    Iman Hadavi
    Majid Hashemi
    Gholamreza Asadikaram
    Davood Kalantar-Neyestanaki
    Ali Hosseininasab
    Tooba Darijani
    Maryam Faraji
    International Journal of Environmental Research, 2022, 16
  • [8] Investigation of SARS-CoV-2 Genome in the Indoor Air and High-Touch Surfaces
    Hadavi, Iman
    Hashemi, Majid
    Asadikaram, Gholamreza
    Kalantar-Neyestanaki, Davood
    Hosseininasab, Ali
    Darijani, Tooba
    Faraji, Maryam
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2022, 16 (06)
  • [9] A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran
    Faridi, Sasan
    Niazi, Sadegh
    Sadeghi, Kaveh
    Naddafi, Kazem
    Yavarian, Jila
    Shamsipour, Mansour
    Jandaghi, Nazanin Zahra Shafiei
    Sadeghniiat, Khosro
    Nabizadeh, Ramin
    Yunesian, Masud
    Momeniha, Fatemeh
    Mokamel, Adel
    Hassanvand, Mohammad Sadegh
    MokhtariAzad, Talat
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 725
  • [10] Letter to the editor “Investigation of SARS-CoV-2 in hospital indoor air of COVID-19 patients’ ward with impinger method”
    Fazel Mohammadi-Moghadam
    Sara Hemati
    Environmental Science and Pollution Research, 2021, 28 : 58812 - 58813