Investigating State Restriction in Fluorescent Protein FRET Using Time-Resolved Fluorescence and Anisotropy

被引:9
|
作者
Blacker, Thomas S. [1 ,2 ,3 ]
Chen, WeiYue [4 ]
Avezov, Edward [5 ]
Marsh, Richard J. [1 ,6 ]
Duchen, Michael R. [3 ]
Kaminski, Clemens F. [4 ]
Bain, Angus J. [1 ,2 ]
机构
[1] UCL, Dept Phys & Astron, Gower St, London WC1E 6BT, England
[2] UCL, Ctr Math & Phys Life Sci & Expt Biol, Gower St, London WC1E 6BT, England
[3] UCL, Dept Cell & Dev Biol, Gower St, London WC1E 6BT, England
[4] Univ Cambridge, Dept Chem Engn & Biotechnol, Pembroke St, Cambridge CB2 3RA, England
[5] Univ Cambridge, Cambridge Inst Med Res, Cambridge CB2 0XY, England
[6] Kings Coll London, Canc Cell Biol & Imaging, New Hunts House,Newcomen St, London SE1 1UL, England
来源
JOURNAL OF PHYSICAL CHEMISTRY C | 2017年 / 121卷 / 03期
基金
英国惠康基金; 英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
RESONANCE ENERGY-TRANSFER; GLUTATHIONE-S-TRANSFERASE; LIVING CELLS; INTERNAL ROTATIONS; FORSTER DISTANCES; LIFETIME; ACCEPTOR; SYSTEM; DEPOLARIZATION; STOICHIOMETRY;
D O I
10.1021/acs.jpcc.6b11235
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Most fluorescent proteins exhibit multiexponential fluorescence decays, indicating a heterogeneous excited state population. FRET between fluorescent proteins should therefore involve multiple energy transfer pathways. We recently demonstrated the FRET pathways between EGFP and mCherry (mC), upon the dimerization of 3-phosphoinositide dependent protein kinase 1 (PDK1); to be highly restricted. A mechanism for FRET restriction based on a highly unfavorable k(2) orientation factor arising from differences in donor-acceptor transition dipole moment angles in a far from coplanar and near static interaction geometry was proposed. Here this is tested via FRET to mC arising from the association of glutathione (GSH) and glutathione S-transferase (GST) with an intrinsically homogeneous and more mobile donor Oregon Green 488 (OG). A new analysis of the acceptor window intensity, based on the turnover point of the sensitized fluorescence, is combined with donor window intensity and anisotropy measurements which show that unrestricted FRET to mC takes place. However, a long-lived anisotropy decay component in the donor window reveals a GST-GSH population in which FRET does not occur, explaining previous discrepancies between quantitative FRET measurements of GST-GSH association and their accepted values. This reinforces the importance of the local donor acceptor environment in mediating energy transfer and the need to perform spectrally resolved intensity and anisotropy decay measurements in the accurate quantification of fluorescent protein FRET.
引用
收藏
页码:1507 / 1514
页数:8
相关论文
共 50 条
  • [41] A review of the analysis of complex time-resolved fluorescence anisotropy data
    Smith, Trevor A.
    Ghiggino, Kenneth P.
    METHODS AND APPLICATIONS IN FLUORESCENCE, 2015, 3 (02):
  • [42] TIME-RESOLVED FLUORESCENCE ANISOTROPY STUDIES OF POLYELECTROLYTE BEHAVIOR IN SOLUTION
    SOUTAR, I
    SWANSON, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 552 - POLY
  • [43] Three Simultaneous Fluorescence Resonance Energy Transfer Processes and Structural Relaxation of Enhanced Yellow Fluorescent Protein Observed by Picosecond Time-Resolved Fluorescence Anisotropy
    Tsubota, Hiroki
    Takayama, Aimi
    Takeda, Yuri
    Yamada, Natsumi
    Hosoi, Haruko
    JOURNAL OF PHYSICAL CHEMISTRY B, 2021, 125 (29): : 7997 - 8009
  • [44] Modeling the Rotational Dynamics of Novel Hetero-FRET Probes as Measured using Time-Resolved Anisotropy
    Leighton, Ryan E.
    Leopold, Hannah
    Schwarz, Jacob
    Boersma, Arnold J.
    Sheets, Erin D.
    Heikal, Ahmed A.
    BIOPHYSICAL JOURNAL, 2018, 114 (03) : 341A - 342A
  • [45] Time-resolved FRET gains in popularity
    Marusina, Kate
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2008, 28 (02): : 16 - +
  • [46] STEADY-STATE AND TIME-RESOLVED FLUORESCENCE ANISOTROPY OF 7-AZAINDOLE AND ITS DERIVATIVES
    RICH, RL
    CHEN, Y
    NEVEN, D
    NEGRERIE, M
    GAI, F
    PETRICH, JW
    JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (09): : 1781 - 1788
  • [47] Fluorescent emission of erythrocyte suspension with time-resolved fluorescence spectrometer
    Han, Caiqin
    Duan, Peitong
    Liu, Ying
    Luo, Xiaosen
    Ni, Xiaowu
    Guangxue Xuebao/Acta Optica Sinica, 2012, 32 (04):
  • [48] ORIENTATIONAL DYNAMICS IN LIPID-PROTEIN MODEL SYSTEMS AS OBSERVED BY TIME-RESOLVED FLUORESCENCE ANISOTROPY
    BEST, L
    JAHNIG, F
    BIOPHYSICS OF STRUCTURE AND MECHANISM, 1981, 7 (04): : 289 - 289
  • [49] In vivo Time-resolved Fluorescence Imaging of a NIR FRET Probe in Live Mice
    Zhao, Lingling
    Abe, Ken
    Barroso, Margarida
    Intes, Xavier
    2013 39TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC 2013), 2013, : 133 - +
  • [50] A sensitive time-resolved fluorescent immunoassay for metallothionein protein
    Butcher, H
    Kennette, W
    Collins, O
    Demoor, J
    Koropatnick, J
    JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 272 (1-2) : 247 - 256