Measurement of scattered and transmitted x-rays from intra-oral and panoramic dental x-ray equipment

被引:2
|
作者
Holroyd, John [1 ]
机构
[1] Publ Hlth England, Didcot OX11 0RQ, Oxon, England
关键词
dental x-ray; occupational exposure; intra-oral; panoramic; RADIOGRAPHY;
D O I
10.1088/1361-6498/aabce3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to quantify the levels of transmitted radiation arising from the use of intra-oral dental x-ray equipment and scattered radiation arising from the use of both intra-oral and panoramic x-ray equipment. Levels of scattered radiation were measured at 1 m from a phantom, using an ion chamber with a volume of 1800 cm(3). Transmitted radiation was measured using both (i) a phantom and dose-area product (DAP) meter and (ii) a patient and a 1800 cm(3) ion chamber. For intra-oral radiography the patient study gave a maximum transmission of 1.80% (range 0.04-1.80%, mean 0.26%) and the phantom study gave a maximum transmission of 6% (range 2-6%, mean 5%). The maximum scattered radiation, per unit DAP, was 5.5 nGy (mGy cm(2))(-1) at 70 kVp and a distance of 1 m. For panoramic radiography the maximum scattered radiation was 9.3 nGy (mGy cm(2))(-1) at 80 kVp and a distance of 1 m. Dose values are presented to enable the calculation of adequate protective measures for dental radiography rooms. Previous studies have used a phantom and measured radiation doses at 1 m from the phantom to determine the radiation dose transmitted through a patient, whereas this study uses both patient and phantom measurements together with a large-area dosemeter, positioned to capture the entire x-ray beam, to ensure that more realistic dose measurements can be made.
引用
收藏
页码:793 / 806
页数:14
相关论文
共 50 条
  • [1] Scattered x-rays in x-ray photography
    Wilsey, RB
    JOURNAL OF THE FRANKLIN INSTITUTE, 1922, 194 : 583 - 596
  • [2] Simulation of transmitted X-rays in a polycapillary X-ray lens
    Peng, Shiqi
    Liu, Zhiguo
    Sun, Tianxi
    Wang, Kai
    Yi, Longtao
    Yang, Kui
    Chen, Man
    Wang, Jinbang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 186 - 191
  • [4] SCATTERED X-RAYS AS INTERNAL STANDARDS IN X-RAY EMISSION SPECTROSCOPY
    ANDERMANN, G
    KEMP, JW
    ANALYTICAL CHEMISTRY, 1958, 30 (08) : 1306 - 1309
  • [5] PANORAMIC X-RAY EQUIPMENT
    VANAKEN, J
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1973, 86 (05): : 1050 - 1059
  • [6] Intra-oral x-ray room shielding evaluation
    Tonry, L
    HEALTH PHYSICS, 2002, 83 (11): : S60 - S64
  • [7] Measurement of spectra for intra-oral X-ray beams using biological materials as attenuator
    Zenobio, Madelon A. F.
    Nogueira-Tavares, Maria S.
    Zenobio, Elton G.
    Squair, Peterson Lima
    Santos, Marcus A. P.
    da Silva, Teogenes A.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 2100 - 2102
  • [8] CMOS Digital Intra-Oral Sensor for X-Ray Radiography
    Liu, Xinqiao
    Byczko, Andrew
    Choi, Marcus
    Chung, Lap
    Do, Hung
    Fowler, Boyd
    Ispasoiu, Radu
    Joshi, Kumar
    Miller, Todd
    Nagy, Alex
    Reaves, David
    Rodricks, Brian
    Teeter, Doug
    Wang, George
    Xiao, Feng
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [9] Comparative analysis of tomography based on transmitted and scattered X-rays
    V. A. Gorshkov
    M. Kröning
    Russian Journal of Nondestructive Testing, 2006, 42 : 278 - 286
  • [10] Application of liquid scintillation light guide (LSLG) to scattered X-ray measurement from dental panoramic radiography system
    Nomura K.
    Takahashi M.
    Fujibuch T.
    Koike Y.
    Hara M.
    Higaki S.
    Kobayashi I.
    Yoshino S.
    Applied Radiation and Isotopes, 2023, 194