Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling

被引:70
|
作者
Lipczynska, Aleksandra [1 ,2 ]
Kaczmarczyk, Jan [1 ]
Melikov, Arsen K. [2 ]
机构
[1] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, PL-44100 Gliwice, Poland
[2] Tech Univ Denmark, Dept Civil Engn, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
Personalized ventilation; Radiant cooling; Thermal comfort; Contaminant distribution; Personal exposure; DISPLACEMENT VENTILATION; EVAPORATIVE COOLER; HUMAN RESPONSE; PERFORMANCE; COMFORT; CONJUNCTION; TEMPERATURE; DESIGN; SYSTEM; HEALTH;
D O I
10.1016/j.buildenv.2015.05.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal environment and air quality conditions provided with combined system of chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for two occupants. The proposed system was compared with total volume HVAC solutions used today, namely mixing ventilation and chilled ceiling combined with mixing ventilation. The objective of the study was to evaluate whether PV can be the only ventilation system in the rooms equipped with chilled ceiling. The room air temperature was 26 degrees C in cases with traditional systems and 28 degrees C when PV was used. PV supplied air with the temperature of 25 degrees C. PV improved thermal conditions and was up to nearly 10 times more efficient in delivering clean air at workstations than mixing ventilation systems, which resulted in strong protection of occupants from the cross-infection. In the room space outside workstations no substantial differences in thermal environment were found between studied systems. The room air mixing with PV working alone was at the same level as with mixing ventilation. No substantial differences in contaminants' concentration distribution and air-change effectiveness were found between the studied systems in the occupied zone outside workstations. (C) 2015 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:603 / 614
页数:12
相关论文
共 50 条
  • [21] Investigating the Performance of Ceiling Mounted Personalized Ventilation System Assisted by Chair Fans: Assessment of Thermal Comfort and Indoor Air Quality
    El Fil, Bachir
    Ghaddar, Nesreen
    Ghali, Kamel
    SECOND INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN: MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2016, : 138 - 145
  • [22] Thermal environment and ventilation efficiency in a simulated office room with personalized micro-environment and fully mixed ventilation systems
    Zhao, Weixin
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    Lestinen, Sami
    Mustakallio, Panu
    BUILDING AND ENVIRONMENT, 2021, 188
  • [23] On indoor thermal environment utilizing tunnel air for ventilation in an office building
    Liu, ZH
    Xie, D
    Chen, G
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 203 - 209
  • [24] NUMERICAL INVESTIGATION OF OFFICE ROOM VENTILATION BY ADOPTING DISPLACEMENT VENTILATION AND CHILLED CEILING SYSTEM IN A HOT AND DRY CLIMATE
    Shbeeb, Ali A.
    Mahdi, Ala'a A.
    Hussein, Ahmed K.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2022, 17 (04): : 2958 - 2982
  • [25] Effectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system
    Sorour Alotaibi
    Walid Chakroun
    Carine Habchi
    Kamel Ghali
    Nesreen Ghaddar
    Building Simulation, 2018, 11 : 773 - 786
  • [26] Effectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system
    Alotaibi, Sorour
    Chakroun, Walid
    Habchi, Carine
    Ghali, Kamel
    Ghaddar, Nesreen
    BUILDING SIMULATION, 2018, 11 (04) : 773 - 786
  • [27] Effectiveness of intermittent personalized ventilation assisting Chilled ceiling in protecting occupants against active particles
    Al-Assad, Douaa
    Ghaddar, Nesreen
    Ghali, Kamel
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2019, 2019,
  • [28] The Energy-Saving Potential of Chilled Ceilings Combined with Personalized Ventilation
    Lipczynska, Aleksandra
    Kaczmarczyk, Jan
    Melikov, Arsen
    ENERGIES, 2021, 14 (04)
  • [29] Optimizing performance of ceiling-mounted personalized ventilation system assisted by chair fans: Assessment of thermal comfort and indoor air quality
    El-Fil, Bachir
    Ghaddar, Nesreen
    Ghali, Kamel
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (04) : 412 - 430
  • [30] Comparison of indoor thermal environment of an office with three operational modes of chilled panel and displacement ventilation system
    Zhao, Lei
    Yuan, Feng
    2006 XI'AN INTERNATIONAL CONFERENCE OF ARCHITECTURE AND TECHNOLOGY, PROCEEDINGS: ARCHITECTURE IN HARMONY, 2006, : 713 - 719