Volume self-calibration for 3D particle image velocimetry

被引:421
|
作者
Wieneke, B. [1 ]
机构
[1] LaVis GmbH, D-37081 Gottingen, Germany
关键词
D O I
10.1007/s00348-008-0521-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error ('disparity') is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.
引用
下载
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [31] Self-Calibration of an Industrial Robot Using a Novel Affordable 3D Measuring Device
    Gaudreault, Martin
    Joubair, Ahmed
    Bonev, Ilian
    SENSORS, 2018, 18 (10)
  • [32] Airflow and acoustic optimization of cooling devices using 3D particle image velocimetry
    Cordova, J. A.
    Trautman, M. A.
    Beltman, W. M.
    PROCEEDINGS OF ISMA2006: INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING, VOLS 1-8, 2006, : 583 - 593
  • [33] Numerical and experimental comparison of 3D Particle Tracking Velocimetry (PTV) and Particle Image Velocimetry (PIV) accuracy for indoor airflow study
    Fu, Sijie
    Biwole, Pascal Henry
    Mathis, Christian
    BUILDING AND ENVIRONMENT, 2016, 100 : 40 - 49
  • [34] Image-plane self-calibration in interferometry
    Carilli, Christopher L.
    Nikolic, Bojan
    Thyagarajan, Nithyanandan
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2022, 39 (12) : 2214 - 2223
  • [35] SELF-CALIBRATION TECHNIQUE FOR A/D CONVERTERS
    LEE, HS
    HODGES, DA
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1983, 30 (03): : 188 - 190
  • [36] Image Mosaicing Using a Self-Calibration Camera
    Baataoui, A.
    Laraqui, A.
    Saaidi, A.
    Satori, K.
    Jarrar, A.
    Masrar, Med.
    3D RESEARCH, 2015, 6 (02):
  • [37] Application of 3D Particle Tracking Velocimetry in Convection
    Wegfrass, A.
    Lobutova, E.
    Resagk, C.
    PROGRESS IN TURBULENCE AND WIND ENERGY IV, 2012, 141 : 297 - 300
  • [38] Wavefront sensing for 3D particle metrology and velocimetry
    Angarita-Jaimes, N.
    McGhee, E.
    Chennaoui, M.
    Campbell, H. I.
    Zhang, S.
    Towers, C. E.
    Greenaway, A. H.
    Towers, D. P.
    INTERFEROMETRY XIII: TECHNIQUES AND ANALYSIS, 2006, 6292
  • [39] 3D particle streak velocimetry by defocused imaging
    Dong, Xiangrui
    Wang, Xiaoxiao
    Zhou, Wu
    Wang, Fangting
    Tang, Xinran
    Cai, Xiaoshu
    PARTICUOLOGY, 2023, 72 : 1 - 9
  • [40] A simple calibration technique for stereoscopic particle image velocimetry
    Andreas Fouras
    Jonathan Dusting
    Kerry Hourigan
    Experiments in Fluids, 2007, 42 : 799 - 810