Volume self-calibration for 3D particle image velocimetry

被引:421
|
作者
Wieneke, B. [1 ]
机构
[1] LaVis GmbH, D-37081 Gottingen, Germany
关键词
D O I
10.1007/s00348-008-0521-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error ('disparity') is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [21] Self-Calibration from Image Derivatives
    Tomáš Brodský
    Cornelia Fermüller
    International Journal of Computer Vision, 2002, 48 : 91 - 114
  • [22] Self-calibration from image derivatives
    Brodsky, T
    Fermuller, C
    Aloimonos, Y
    SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 83 - 89
  • [23] Self-calibration from image derivatives
    Brodsky, T
    Fermüller, C
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2002, 48 (02) : 91 - 114
  • [24] 3D scanning particle tracking velocimetry
    Hoyer, K
    Holzner, M
    Lüthi, B
    Guala, M
    Liberzon, A
    Kinzelbach, W
    EXPERIMENTS IN FLUIDS, 2005, 39 (05) : 923 - 934
  • [25] 3D scanning particle tracking velocimetry
    Klaus Hoyer
    Markus Holzner
    Beat Lüthi
    Michele Guala
    Alexander Liberzon
    Wolfgang Kinzelbach
    Experiments in Fluids, 2005, 39 : 923 - 934
  • [26] Self-calibration based 3D information extraction and application in broadcast soccer video
    Liu, Y
    Liang, DW
    Huang, QM
    Gao, W
    COMPUTER VISION - ACCV 2006, PT II, 2006, 3852 : 852 - 861
  • [27] Self-calibration of a vehicle's acquisition system with cameras, IMU and 3D lidar
    Deymier, Clement
    Teuliere, Celine
    Chateau, Thierry
    TRAITEMENT DU SIGNAL, 2015, 32 (2-3) : 121 - 145
  • [28] Self-Calibration 3D Hybrid SERS Substrate and Its Application in Quantitative Analysis
    Fu, Bei-Bei
    Tian, Xiang-Dong
    Song, Jing-Jin
    Wen, Bao-Ying
    Zhang, Yue-Jiao
    Fang, Ping-Ping
    Li, Jian-Feng
    ANALYTICAL CHEMISTRY, 2022, 94 (27) : 9578 - 9585
  • [29] A robustness study of self-calibration technique for the radiographic 3D reconstruction of human spine
    Remaki, L
    Cheriet, F
    Bellefleur, C
    Labelle, H
    Dansereau, J
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 95 - 95
  • [30] Self-calibration of depth sensing systems based on structured-light 3D
    Ramachandra, Vikas
    Nash, James
    Atanassov, Kalin
    Goma, Sergio
    THREE-DIMENSIONAL IMAGE PROCESSING (3DIP) AND APPLICATIONS 2013, 2013, 8650