Continuous Discharge Monitoring Using Non-contact Methods for Velocity Measurements: Uncertainty Analysis

被引:0
|
作者
Corato, G. [1 ]
Moramarco, T. [2 ]
Tucciarelli, T. [3 ]
Fulton, J. W. [4 ]
机构
[1] Ctr Rech Publ Gabriel Lippmann, L-4422 Belvaux, Luxembourg
[2] CNR, Res Inst Geohydrol Protect, I-06128 Perugia, Italy
[3] Univ Palermo, Dept Civil Environm & Aerosp Engn, I-90128 Palermo, Italy
[4] US Geol Survey, Colorado Water Sci Ctr, Lakewood, CO 80225 USA
关键词
Discharge estimation; Entropy; Hydraulic modeling; Uncertainty; MODELS;
D O I
10.1007/978-3-319-09054-2_123
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
At gauged site, water stage and discharge hydrographs can be related also during unsteady flow conditions, using the one-dimensional diffusive hydraulic model, DORA, and exploiting sporadic surface velocity measurements carried out with a radar sensor, during the rising limb of the flood. Indeed, starting from the measured surface velocity, the application of a simplified entropic velocity distribution model allows obtaining the benchmark discharge for the Manning's roughness calibration. The aim of this work is twofold. First, to address the uncertainty of the approach. Second, to detect the minimum water level along the rising limb in which the occasional surface velocity measurement should be carried out. Several historical events recorded along the Upper Tiber River, Central Italy, are used to this end. Results show that when the DORA model calibration is performed at water levels greater than 60 % of maximum historical one, it is possible to estimate the whole discharge hydrograph with good accuracy and quite narrow confidence band.
引用
收藏
页码:617 / 621
页数:5
相关论文
共 50 条
  • [41] Non-contact ECG Monitoring for Driver
    Stork, Milan
    Houzar, Josef
    PROCEEDINGS OF THE 2020 30TH INTERNATIONAL CONFERENCE RADIOELEKTRONIKA (RADIOELEKTRONIKA), 2020, : 57 - 61
  • [42] Non-contact measurement of pulse wave velocity using RGB cameras
    Nakano, Kazuya
    Aoki, Yuta
    Satoh, Ryota
    Hoshi, Akira
    Suzuki, Hiroyuki
    Nishidate, Izumi
    OPTICAL DIAGNOSTICS AND SENSING XVI: TOWARD POINT-OF-CARE DIAGNOSTICS, 2016, 9715
  • [43] Non-contact drug tablet monitoring
    Varghese, I
    Ban, L
    Peri, MDM
    Li, C
    Subramanian, G
    Cetinkaya, C
    CONTROL ENGINEERING, 2006, 53 (02) : RX1 - +
  • [44] Non-contact measurement of surface flow velocity using photoelectric method
    Wu, Jun
    Ding, Shen-Qi
    Yu, Kui
    Li, Xiao-Biao
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (02): : 349 - 356
  • [45] THEORETICAL INVESTIGATION OF NON-CONTACT VELOCITY MEASUREMENT USING AN OPTICAL GRID
    KREUTZER, P
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1975, 83 (06): : 289 - 294
  • [46] Non-contact in situ microwave material measurements for high temperature process monitoring
    Sivaprakasam, Balamurugan T.
    Krishnamurthy, C. V.
    Arunachalam, Kavitha
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (03):
  • [47] INDUCTIVE NON-CONTACT METHOD FOR MEASURING A VELOCITY
    GAJEWSKI, JB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (07): : 622 - 624
  • [48] Non-contact flood discharge measurements using an X-band pulse radar (II) Improvements and applications
    Lee, MC
    Leu, JM
    Lai, CJ
    Plant, WJ
    Keller, WC
    Hayes, K
    FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 13 (5-6) : 271 - 276
  • [49] Measurement of Automotive Parts' Surface Texture Using Contact and Non-contact Methods
    Harcarik, Matej
    Jankovych, Robert
    PROCEEDINGS OF THE 2016 17TH INTERNATIONAL CONFERENCE ON MECHATRONICS - MECHATRONIKA (ME) 2016, 2016, : 374 - 380
  • [50] Evaluation of contact welding and strengthening of joints by non-contact discharge
    Egashira, Mitsuru
    Konno, Takeshi
    Kobayashi, Mikihiko
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2006, 7 (07) : 745 - 751