Continuous Discharge Monitoring Using Non-contact Methods for Velocity Measurements: Uncertainty Analysis

被引:0
|
作者
Corato, G. [1 ]
Moramarco, T. [2 ]
Tucciarelli, T. [3 ]
Fulton, J. W. [4 ]
机构
[1] Ctr Rech Publ Gabriel Lippmann, L-4422 Belvaux, Luxembourg
[2] CNR, Res Inst Geohydrol Protect, I-06128 Perugia, Italy
[3] Univ Palermo, Dept Civil Environm & Aerosp Engn, I-90128 Palermo, Italy
[4] US Geol Survey, Colorado Water Sci Ctr, Lakewood, CO 80225 USA
关键词
Discharge estimation; Entropy; Hydraulic modeling; Uncertainty; MODELS;
D O I
10.1007/978-3-319-09054-2_123
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
At gauged site, water stage and discharge hydrographs can be related also during unsteady flow conditions, using the one-dimensional diffusive hydraulic model, DORA, and exploiting sporadic surface velocity measurements carried out with a radar sensor, during the rising limb of the flood. Indeed, starting from the measured surface velocity, the application of a simplified entropic velocity distribution model allows obtaining the benchmark discharge for the Manning's roughness calibration. The aim of this work is twofold. First, to address the uncertainty of the approach. Second, to detect the minimum water level along the rising limb in which the occasional surface velocity measurement should be carried out. Several historical events recorded along the Upper Tiber River, Central Italy, are used to this end. Results show that when the DORA model calibration is performed at water levels greater than 60 % of maximum historical one, it is possible to estimate the whole discharge hydrograph with good accuracy and quite narrow confidence band.
引用
收藏
页码:617 / 621
页数:5
相关论文
共 50 条
  • [21] NON-CONTACT ECG MONITORING
    Smirnov, Alexey S.
    Erlikh, Vadim V.
    Kodkin, Vladimir L.
    Keller, Andrei V.
    Epishev, Vitaly V.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [22] Non-contact ECG monitoring
    Brydon, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 641 - 641
  • [23] Non-contact velocity sensor simulator
    Fainberg, ME
    Skrylev, PA
    Smart Imagers and Their Application, 2005, 5944 : 210 - 213
  • [24] Non-Contact Vital Sign Monitoring of Cat Using Continuous-Wave Doppler Radar
    Lai, Jun
    Lu, Jingyun
    Gu, Changzhan
    Mao, Jun-Fa
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [25] Continuous non-contact respiratory rate and tidal volume monitoring using a Depth Sensing Camera
    Addison, Paul S.
    Smit, Philip
    Jacquel, Dominique
    Addison, Anthony P.
    Miller, Cyndy
    Kimm, Gardner
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (03) : 657 - 665
  • [26] Contact and Non-contact Measurements of Grinding Pins
    Magdziak, Marek
    Wdowik, Roman
    2015 4TH INTERNATIONAL CONFERENCE ON MECHANICS AND CONTROL ENGINEERING (ICMCE 2015), 2015, 35
  • [27] SKIN COLOUR MEASUREMENT BY USING NON-CONTACT METHODS
    Wang, M.
    Xiao, K.
    Wuerger, S.
    Liu, H. X.
    Huang, M.
    Luo, M. R.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 487 - 492
  • [28] Non-contact flood discharge measurements using an X-band pulse radar (I) theory
    Lee, MC
    Lai, CJ
    Leu, JM
    Plant, WJ
    Keller, WC
    Hayes, K
    FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 13 (5-6) : 265 - 270
  • [29] APPLICATION OF NON-CONTACT METHODS TO EXPERIMENTAL MEASUREMENTS OF HUMAN BODY VIBRATION
    Ksiazek, Marek A.
    Tarnowski, Janusz
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2008, 46 (04) : 845 - 867
  • [30] Non-Contact High Voltage Measurement in the Online Partial Discharge Monitoring System
    Walczak, Krzysztof
    Sikorski, Wojciech
    ENERGIES, 2021, 14 (18)