Continuous Discharge Monitoring Using Non-contact Methods for Velocity Measurements: Uncertainty Analysis

被引:0
|
作者
Corato, G. [1 ]
Moramarco, T. [2 ]
Tucciarelli, T. [3 ]
Fulton, J. W. [4 ]
机构
[1] Ctr Rech Publ Gabriel Lippmann, L-4422 Belvaux, Luxembourg
[2] CNR, Res Inst Geohydrol Protect, I-06128 Perugia, Italy
[3] Univ Palermo, Dept Civil Environm & Aerosp Engn, I-90128 Palermo, Italy
[4] US Geol Survey, Colorado Water Sci Ctr, Lakewood, CO 80225 USA
关键词
Discharge estimation; Entropy; Hydraulic modeling; Uncertainty; MODELS;
D O I
10.1007/978-3-319-09054-2_123
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
At gauged site, water stage and discharge hydrographs can be related also during unsteady flow conditions, using the one-dimensional diffusive hydraulic model, DORA, and exploiting sporadic surface velocity measurements carried out with a radar sensor, during the rising limb of the flood. Indeed, starting from the measured surface velocity, the application of a simplified entropic velocity distribution model allows obtaining the benchmark discharge for the Manning's roughness calibration. The aim of this work is twofold. First, to address the uncertainty of the approach. Second, to detect the minimum water level along the rising limb in which the occasional surface velocity measurement should be carried out. Several historical events recorded along the Upper Tiber River, Central Italy, are used to this end. Results show that when the DORA model calibration is performed at water levels greater than 60 % of maximum historical one, it is possible to estimate the whole discharge hydrograph with good accuracy and quite narrow confidence band.
引用
收藏
页码:617 / 621
页数:5
相关论文
共 50 条
  • [1] Continuous non-contact river discharge measurements
    Cheng, RT
    Costa, JE
    Mason, RR
    Plant, WJ
    Gartner, JW
    Spicer, K
    Haeni, FP
    Melcher, N
    PROCEEDINGS OF THE NINTH INTERNATIONAL SYMPOSIUM ON RIVER SEDIMENTATION, VOLS 1-4, 2004, : 2535 - 2542
  • [2] Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
    Dosso, Yasmina Souley
    Greenwood, Kimberley J.
    Harrold, Joann
    Green, James R.
    IEEE ACCESS, 2023, 11 : 144168 - 144179
  • [3] THE METHODS FOR NON-CONTACT TEMPERATURE MONITORING
    NAKAMURA, K
    KAWATA, K
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1982, 27 (11): : 794 - 799
  • [4] Optical Methods in Non-contact Velocity Measurement
    Smid, Petr
    PROCEEDINGS OF THE 48TH INTERNATIONAL SCIENTIFIC CONFERENCE ON EXPERIMENTALNI ANALYZA NAPETI 2010 EXPERIMENTAL STRESS ANALYSIS, 2010, : 401 - 406
  • [5] Continuous non-contact monitoring of neonatal activity
    Paul S. Addison
    Dale Gerstmann
    Jeffrey Clemmer
    Rena Nelson
    Mridula Gunturi
    Dean Montgomery
    Sam Ajizian
    BMC Pediatrics, 25 (1)
  • [6] Uncertainty evaluation in non-contact aperture area measurements
    Razet, A.
    Bastie, J.
    METROLOGIA, 2006, 43 (05) : 361 - 366
  • [7] Passive Continuous Electrocardiogram Monitoring of Firemen Using Non-Contact Electrodes
    Ritchie, Peter
    Huerta, Miguel
    Lau, Tuen Lung
    Agee, Jules
    Cao, Hung
    Chiao, J. -C.
    2017 IEEE SENSORS, 2017, : 1101 - 1103
  • [8] A Non-contact Directional Sensor for Partial Discharge Measurements
    Sack, Kevin
    Su, Charles Q.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [9] Optical methods for non-contact measurements of membranes
    Roose, S.
    Stockman, Y.
    Rochus, P.
    Kuhn, T.
    Lang, M.
    Baier, H.
    Langlois, S.
    Casarosa, G.
    ACTA ASTRONAUTICA, 2009, 65 (9-10) : 1317 - 1329
  • [10] Non-contact measurements using light
    Woppowa, L
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2000, 60 (7-8): : 273 - 274