How reliable are Hounsfield-unit measurements in forensic radiology?

被引:32
|
作者
Ruder, Thomas D. [1 ]
Thali, Yannick [1 ]
Schindera, Sebastian T. [2 ]
Dalla Torre, Simon A. [3 ]
Zech, Wolf-Dieter [4 ]
Thali, Michael J. [1 ,4 ]
Ross, Steffen [1 ]
Hatch, Gary M. [1 ]
机构
[1] Univ Bern, Inst Forens Med, Ctr Forens Imaging & Virtopsy, CH-3012 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Inst Radiol, CH-3010 Bern, Switzerland
[3] Swiss Agcy Therapeut Prod, Swissmed, CH-3000 Bern 9, Switzerland
[4] Univ Bern, Inst Forens Med, Dept Forens Pathol, CH-3012 Bern, Switzerland
关键词
Forensic radiology; Computed tomography; HU measurements; Object identification; Reliability; Reference model; MULTISLICE COMPUTED-TOMOGRAPHY; BONE-MINERAL MEASUREMENTS; QUALITY-CONTROL; PHANTOM; CT; STANDARDIZATION; IDENTIFICATION; SPINE; QCT; DXA;
D O I
10.1016/j.forsciint.2012.03.004
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Objective: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. Materials and methods: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. Results: HU values did not change significantly as a function of ROI-shape or -size (p > 0.05). Intra-reader reliability reached ICC values >0.929 (p < 0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p < 0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p < 0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p < 0.05). Conclusion: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 50 条
  • [31] Relation of computerized tomography Hounsfield unit measurements and internal components of fresh chestnuts (Castanea spp.)
    Donis-Gonzalez, Irwin R.
    Guyer, Daniel E.
    Pease, Anthony
    Fulbright, Dennis W.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2012, 64 (01) : 74 - 82
  • [32] Inter-Rater Reliability and Correlation of L1 Hounsfield Unit Measurements with DXA Scores
    Mooney, James
    Morgan, Sarah
    Brockington, David
    Rehder, Dirk
    Rothenberg, Steven
    Omar, Nidal
    MacLennan, Paul
    Chambers, M. R.
    JOURNAL OF CLINICAL DENSITOMETRY, 2022, 25 (04) : 668 - 673
  • [33] THE CT (HOUNSFIELD UNIT) NUMBER OF BRAIN-TISSUE IN HEALTHY INFANTS - A NEW RELIABLE METHOD FOR DETECTION OF POSSIBLE DEGENERATIVE DISEASE
    BORIS, P
    BUNDGAARD, F
    OLSEN, A
    CHILDS NERVOUS SYSTEM, 1987, 3 (03) : 175 - 177
  • [34] How Reliable Are Enantiomeric Excess Measurements Obtained By Chiral HPLC?
    Payne, Curtis
    Kass, Steven R.
    CHEMISTRYSELECT, 2020, 5 (06): : 1810 - 1817
  • [35] Preliminary X-ray CT investigation to link Hounsfield unit measurements with the International System of Units (SI)
    Levine, Zachary H.
    Peskin, Adele P.
    Holmgren, Andrew D.
    Garboczi, Edward J.
    PLOS ONE, 2018, 13 (12):
  • [36] How Many Digits Should Be Reported In Forensic Breath Alcohol Measurements?
    Gullberg, Rod G.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (05) : 411 - 414
  • [37] Combining Mean and Standard Deviation of Hounsfield Unit Measurements from Preoperative CT Allows More Accurate Prediction of Urinary Stone Composition Than Mean Hounsfield Units Alone
    Tailly, Thomas
    Larish, Yaniv
    Nadeau, Brandon
    Violette, Philippe
    Glickman, Leonard
    Olvera-Posada, Daniel
    Alenezi, Husain
    Amann, Justin
    Denstedt, John
    Razvi, Hassan
    JOURNAL OF ENDOUROLOGY, 2016, 30 (04) : 453 - 459
  • [38] Evaluation of multidetector CT Hounsfield unit measurements as a predictor of efficacy and complications in percutaneous vertebroplasty for osteoporotic vertebral compression fractures
    Yankov, Dimo
    Bussarsky, Assen
    Karakostov, Vasil
    Sirakov, Alexander
    Ferdinandov, Dilyan
    FRONTIERS IN MEDICINE, 2023, 10
  • [39] How reliable are slit lamp biomicroscopy measurements of anterior segment structures?
    Sagoo, MS
    Malhotra, R
    Constable, R
    EYE, 2001, 15 (4) : 539 - 541
  • [40] How reliable are scanning tunneling microscopy measurements of electron transport in molecules?
    Ford, MJ
    Kirkup, L
    Gentle, A
    Zareie, H
    Cortie, M
    BIOMEMS AND NANOTECHNOLOGY II, 2006, 6036