How reliable are Hounsfield-unit measurements in forensic radiology?

被引:32
|
作者
Ruder, Thomas D. [1 ]
Thali, Yannick [1 ]
Schindera, Sebastian T. [2 ]
Dalla Torre, Simon A. [3 ]
Zech, Wolf-Dieter [4 ]
Thali, Michael J. [1 ,4 ]
Ross, Steffen [1 ]
Hatch, Gary M. [1 ]
机构
[1] Univ Bern, Inst Forens Med, Ctr Forens Imaging & Virtopsy, CH-3012 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Inst Radiol, CH-3010 Bern, Switzerland
[3] Swiss Agcy Therapeut Prod, Swissmed, CH-3000 Bern 9, Switzerland
[4] Univ Bern, Inst Forens Med, Dept Forens Pathol, CH-3012 Bern, Switzerland
关键词
Forensic radiology; Computed tomography; HU measurements; Object identification; Reliability; Reference model; MULTISLICE COMPUTED-TOMOGRAPHY; BONE-MINERAL MEASUREMENTS; QUALITY-CONTROL; PHANTOM; CT; STANDARDIZATION; IDENTIFICATION; SPINE; QCT; DXA;
D O I
10.1016/j.forsciint.2012.03.004
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Objective: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. Materials and methods: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. Results: HU values did not change significantly as a function of ROI-shape or -size (p > 0.05). Intra-reader reliability reached ICC values >0.929 (p < 0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p < 0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p < 0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p < 0.05). Conclusion: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 50 条
  • [21] Correlations among Cervical, Thoracic, and lumbar Hounsfield Unit measurements for assessment of bone mineral density
    Razzouk, Jacob
    Ramos, Omar
    Scolieri, Juliette
    Bouterse, Alex
    Cabrera, Andrew
    Shin, David
    Brandt, Zachary
    Carter, Davis
    Wycliffe, Nathaniel
    Cheng, Wayne
    Danisa, Olumide
    JOURNAL OF CLINICAL NEUROSCIENCE, 2024, 120 : 23 - 28
  • [22] CT texture analysis reliability in pulmonary lesions: the influence of 3D vs. 2D lesion segmentation and volume definition by a Hounsfield-unit threshold
    Gabriel Adelsmayr
    Michael Janisch
    Ann-Katrin Kaufmann-Bühler
    Magdalena Holter
    Emina Talakic
    Elmar Janek
    Andreas Holzinger
    Michael Fuchsjäger
    Helmut Schöllnast
    European Radiology, 2023, 33 : 3064 - 3071
  • [23] How reliable are crystalline silica dust concentration measurements?
    Cox, L. A., Jr.
    Van Orden, D. R.
    Lee, R. J.
    Arlauckas, S. M.
    Kautz, R. A.
    Warzel, A. L.
    Bailey, K. F.
    Ranpuria, A. K.
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2015, 73 (01) : 126 - 136
  • [24] HOW RELIABLE IS SEX DIFFERENTIATION FROM TEETH MEASUREMENTS
    Joseph, Anna P.
    Harish, R. K.
    Mohammed, P. K. Rajeesh
    Kumar, Vinod R. B.
    ORAL & MAXILLOFACIAL PATHOLOGY JOURNAL, 2013, 4 (01) : 289 - 292
  • [25] HOW RELIABLE ARE ULTRASOUND MEASUREMENTS OF RENAL LENGTH IN ADULTS
    ABLETT, MJ
    COULTHARD, A
    LEE, REJ
    RICHARDSON, DL
    BELLAS, T
    OWEN, JP
    KEIR, MJ
    BUTLER, TJ
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814): : 1087 - 1089
  • [26] Patellar Instability Measurements on CT and MRI: How Reliable Are They?
    Thakkar, R.
    Chalian, M.
    Del Grande, F.
    Carrino, J.
    Eng, J.
    Chhabra, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [27] How Reliable Are Raman Spectroscopy Measurements of Graphene Oxide?
    Mehta, Jeremy S.
    Faucett, Austin C.
    Sharma, Anju
    Mativetsky, Jeffrey M.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2017, 121 (30): : 16584 - 16591
  • [28] How reliable are dyssynchrony measurements in the presence of infarct scar?
    Steelant, B.
    Marones, M.
    Stankovic, I.
    Bogaert, J.
    Desmet, W.
    Aakhus, S.
    Voigt, J. U.
    EUROPEAN HEART JOURNAL, 2012, 33 : 480 - 480
  • [29] CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion
    Yao, Yu-Cheng
    Chao, Hsien
    Kao, Kun-Yu
    Lin, Hsi-Hsien
    Wang, Shih-Tien
    Chang, Ming-Chau
    Liu, Chien-Lin
    Chou, Po-Hsin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion
    Yu-Cheng Yao
    Hsien Chao
    Kun-Yu Kao
    Hsi-Hsien Lin
    Shih-Tien Wang
    Ming-Chau Chang
    Chien-Lin Liu
    Po-Hsin Chou
    Scientific Reports, 13