How reliable are Hounsfield-unit measurements in forensic radiology?

被引:32
|
作者
Ruder, Thomas D. [1 ]
Thali, Yannick [1 ]
Schindera, Sebastian T. [2 ]
Dalla Torre, Simon A. [3 ]
Zech, Wolf-Dieter [4 ]
Thali, Michael J. [1 ,4 ]
Ross, Steffen [1 ]
Hatch, Gary M. [1 ]
机构
[1] Univ Bern, Inst Forens Med, Ctr Forens Imaging & Virtopsy, CH-3012 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Inst Radiol, CH-3010 Bern, Switzerland
[3] Swiss Agcy Therapeut Prod, Swissmed, CH-3000 Bern 9, Switzerland
[4] Univ Bern, Inst Forens Med, Dept Forens Pathol, CH-3012 Bern, Switzerland
关键词
Forensic radiology; Computed tomography; HU measurements; Object identification; Reliability; Reference model; MULTISLICE COMPUTED-TOMOGRAPHY; BONE-MINERAL MEASUREMENTS; QUALITY-CONTROL; PHANTOM; CT; STANDARDIZATION; IDENTIFICATION; SPINE; QCT; DXA;
D O I
10.1016/j.forsciint.2012.03.004
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Objective: To assess the reliability of computed tomography (CT) numbers, also known as Hounsfield-units (HU) in the differentiation and identification of forensically relevant materials and to provide instructions to improve the reproducibility of HU measurements in daily forensic practice. Materials and methods: We scanned a phantom containing non-organic materials (glass, rocks and metals) on three different CT scanners with standardized parameters. The t-test was used to assess the influence of the scanner, the size and shape of different types of regions-of-interest (ROI), the composition and shape of the object, and the reader performance on HU measurements. Intra-class correlation coefficient was used to assess intra- and inter-reader reliability. Results: HU values did not change significantly as a function of ROI-shape or -size (p > 0.05). Intra-reader reliability reached ICC values >0.929 (p < 0.001). Inter-reader reliability was also excellent with an ICC of 0.994 (p < 0.001). Four of seven objects yielded significantly different CT numbers at different levels within the object (p < 0.05). In 6/7 objects the HU changed significantly from CT scanner to CT scanner (p < 0.05). Conclusion: Reproducible CT number measurements can be achieved through correct ROI-placement and repeat measurements within the object of interest. However, HU may differ from CT-scanner to CT-scanner. In order to obtain comparable CT numbers we suggest that a dedicated Forensic Reference Phantom be developed. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 50 条
  • [1] Utility of Hounsfield Unit Measurements in Diagnosing Pulmonary Embolism
    Irani, N.
    Dash, N.
    Kim, C.
    Ilkhanipour, K.
    Lupetin, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [2] A Monte Carlo Investigation of Dose Reporting Issue in the Presence of High Hounsfield-Unit Material in Clinical AAA Dose Calculation Algorithm
    Chen, X.
    Fan, J.
    Veltchev, I.
    Li, J.
    Liu, J.
    Ma, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E682 - E682
  • [3] Accuracy of target localization and Hounsfield-unit reconstruction of cone-beam CT acquisition with Varian's On-Board Imager
    Praestegaard, L.
    Poulsen, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S211 - S211
  • [4] Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful?
    Shemesh, Shay
    Luckman, Judith
    Marom, Tal
    Kraus, Oded
    Tamir, Sharon Ovnat
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2022, 26 (03) : E414 - E421
  • [5] VARIABILITY OF HOUNSFIELD UNIT MEASUREMENTS BASED ON CT OF A RENAL CYST
    HOPPER, KD
    HOLABINKO, JN
    HAVE, TRT
    HARTMAN, DS
    RADIOLOGY, 1995, 197 : 147 - 147
  • [6] How Reliable Are Forensic Evaluations of Legal Sanity?
    Gowensmith, W. Neil
    Murrie, Daniel C.
    Boccaccini, Marcus T.
    LAW AND HUMAN BEHAVIOR, 2013, 37 (02) : 98 - 106
  • [7] How reliable are texture measurements?
    Robins, Marthony
    Solomon, Justin
    Hoye, Jocelyn
    Abadi, Ehsan
    Marin, Daniele
    Samei, Ehsan
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [8] How reliable are measurements with arthrometers?
    E. Eriksson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2000, 8 : 131 - 131
  • [9] How reliable are measurements with arthrometers?
    Eriksson, E
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2000, 8 (03) : 131 - 131
  • [10] HOW RELIABLE ARE TUMOR MEASUREMENTS
    GURLAND, J
    JOHNSON, RO
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1965, 194 (09): : 973 - &