Microbial diagnosis of infection and colonization of cardiac implantable electronic devices by use of sonication

被引:18
|
作者
Inacio, Ricardo Cantarim [1 ]
Klautau, Giselle Burlamaqui [2 ]
Murca, Maria Aparecida S. [3 ]
da Silva, Cely Barreto [3 ]
Nigro, Stanley [3 ]
Rivetti, Luiz Antonio [4 ]
Pereira, Wilson Lopes [4 ]
Costa Salles, Mauro Jose [2 ]
机构
[1] Santa Casa Sao Paulo Sch Med Sci, Emergency Serv, BR-01303060 Sao Paulo, SP, Brazil
[2] Santa Casa Sao Paulo Sch Med Sci, Dept Internal Med, Div Infect Dis, BR-01303060 Sao Paulo, SP, Brazil
[3] Santa Casa Sao Paulo Sch Med Sci, Dept Lab Med & Pathol, Div Infect Dis, BR-01303060 Sao Paulo, SP, Brazil
[4] Santa Casa Sao Paulo Sch Med Sci, Dept Surg, Div Infect Dis, BR-01303060 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Sonication; Cardiac implantable electronic devices; Biofilm; Colonization; Infection; BACTERIAL-COLONIZATION; MANAGEMENT; ENDOCARDITIS; PREVALENCE; PACEMAKER; CRITERIA; SOCIETY; CULTURE;
D O I
10.1016/j.ijid.2015.07.018
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: The clinical utility of sonication as an adjunctive diagnostic tool for the microbial diagnosis of cardiac implantable device-associated infections (CIDAIs) was investigated. Methods: The implants of 83 subjects were investigated, 15 with a CIDAI and 68 without a clinical infection. Clinical data were analyzed prospectively and sonication fluid cultures (83 patients, 100%) and traditional cultures (31 patients, 37.4%) were performed Results: Generator pocket infection and device-related endocarditis were found in 13 (86.7%) and four (26.7%) subjects, respectively. The mean numbers of previous technical complications and infections were higher in the infected patients compared to the non-infected patients (8 vs. 1, p < 0.001; 2 vs. 0, p < 0.031, respectively). The sensitivity and specificity for detecting CIDAI was 73.3% (11/15) and 48.5% (33/68) for sonication fluid culture, and 26.7% (4/15) and 100% (16/16) for traditional culture (p < 0.001), respectively. A higher number of organisms were identified by sonication fluid than by tissue culture (58 vs. 4 specimens; p < 0.001). The most frequent organisms cultured were Gram-positive cocci (66.1%), mainly coagulase-negative staphylococci (35.5%). Thirty-five (51.5%) non-infected subjects were considered colonized due to the positive identification of organisms exclusively through sonication fluid culture. Conclusions: Sonication fluid culture from the removed cardiac implants has the potential to improve the microbiological diagnosis of CIDAIs. (C) 2015 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [21] Cybersecurity and cardiac implantable electronic devices
    Bryce Alexander
    Adrian Baranchuk
    Nature Reviews Cardiology, 2020, 17 : 315 - 317
  • [22] Cardiac implantable electronic devices and cybersecurity
    Patel, Bhakti
    Makaryus, Amgad N.
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (18) : 69 - 77
  • [23] Innovations in Cardiac Implantable Electronic Devices
    Khurrum Khan
    Jitae A. Kim
    Andra Gurgu
    Muzamil Khawaja
    Dragos Cozma
    Mihail G. Chelu
    Cardiovascular Drugs and Therapy, 2022, 36 : 763 - 775
  • [24] Cybersecurity in cardiac implantable electronic devices
    Martignani, Cristian
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (06) : 437 - 444
  • [25] MRI and implantable cardiac electronic devices
    Jung, Werner
    Jaeckle, Sebastian
    Zvereva, Vlada
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (01) : 65 - 73
  • [26] Extraction of implantable cardiac electronic devices
    Rickard J.
    Wilkoff B.L.
    Current Cardiology Reports, 2011, 13 (5) : 407 - 414
  • [27] Treatment with cardiac electronic implantable devices
    Kuschyk, Juergen
    Sattler, Katherine
    Fastenrath, Fabian
    Rudic, Boris
    Akin, Ibrahim
    HERZ, 2024, 49 (03) : 233 - 246
  • [28] The use of remote monitoring of patients with cardiac implantable electronic devices in Poland
    Tajstra, Mateusz
    Dyrbus, Maciej
    Grabowski, Marcin
    Rokicki, Jakub K.
    Nowak, Marcin
    Gasior, Mariusz
    KARDIOLOGIA POLSKA, 2022, 80 (04) : 479 - 481
  • [29] Electromagnetic Interference in Cardiac Implantable Electronic Devices Is the Use of Smartphones Safe?
    Lennerz, Carsten
    Pavaci, Herribert
    Grebmer, Christian
    Semmler, Verena
    Bourier, Felix
    Haller, Bernhard
    Reents, Tilko
    Hessling, Gabriele
    Deisenhofer, Isabel
    Kolb, Christof
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (01) : 108 - 110
  • [30] Use of Cardiac Implantable Electronic Devices in Older Adults With Cognitive Impairment
    Fowler, Nicole R.
    Johnson, Kim G.
    Li, Jie
    Moore, Charity G.
    Saba, Samir
    Lopez, Oscar L.
    Barnato, Amber E.
    JAMA INTERNAL MEDICINE, 2014, 174 (09) : 1514 - 1516