Transvenous extraction of pacemaker leads via femoral approach using a gooseneck snare

被引:0
|
作者
Uslu, Abdulkadir [1 ]
Kup, Ayhan [1 ]
Kanar, Batur Gonenc [2 ]
Balaban, Ismail [1 ]
Demir, Serdar [1 ]
Gulsen, Kamil [1 ]
Kepez, Alper [2 ]
Dogan, Cem [1 ]
Candan, Ozkan [1 ]
Akgun, Taylan [1 ]
Altintas, Bernas [3 ]
Sadic, Beste Ozben [2 ]
机构
[1] Kartal Kosuyolu Heart & Vasc Dis Res & Training H, Cardiol Dept, Istanbul, Turkey
[2] Marmara Univ, Fac Med, Cardiol Dept, Istanbul, Turkey
[3] Gazi Yasargil Res & Training Hosp, Cardiol Dept, Diyarbakir, Turkey
关键词
Femoral vein; Endocardium; Radiofrequency ablation; Implantable cardioverter defibrillators; Cardiac pacemakers; CARDIOVERTER-DEFIBRILLATOR LEADS; LASER SHEATH; ASSOCIATION; EXPERIENCE; OUTCOMES; REMOVAL; SOCIETY; PATIENT; SAFETY;
D O I
10.1007/s00059-020-04987-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The growing problem of endocardial lead infections and leadmalfunctions has increased interest in percutaneous lead-removal technology. Transvenous lead extraction (TLE) via simple manual traction (SMT) is the first-line therapy. When SMT is not successful, TLE from the femoral vein using a gooseneck snare (GS) with a radiofrequency ablation catheter (RFAC) may be an alternative option. The aim of our study was to evaluate the success rate of transvenous extraction of chronically implanted leads via the femoral approach using a GS with RFCA in cases of failure with SMT.Methods. The study included 94 consecutive patients who were referred for lead extraction due to pocket erosion and infection (71 patients) and to lead malfunction (23 patients). Initially, SMT was attempted for all patients. If SMT was not successful, patients underwent TLE using a GS with RFAC. Results. Leads were extracted successfully with SMT in 34 patients (54 leads), while 60 patients (83 leads) underwent TLE using a GS with RFAC. The mean indwelling time of the leads was longer in the femoral approach with GS (87.5 +/- 37.9 vs. 31.3 +/- 25.8 months; p< 0.001). The procedural success rate was 96.7% in the femoral approach with GS. A preceding implantation lead duration of >51 months predicted an unsuccessful SMT necessitating alternative TLE using a GS with RFAC with 86% sensitivity and 78% specificity (p< 0.001). Conclusion. Transvenous lead extraction via the femoral approach using GS with RFAC may be an alternative approach to SMT with a high success rate, especially when the indwelling time of the leads is long.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [31] Transvenous embolisation of an arteriovenous malformation of the mandible via a femoral approach
    Beek, FJA
    tenBroek, FW
    vanSchaik, JPJ
    Mall, WPTM
    PEDIATRIC RADIOLOGY, 1997, 27 (11) : 855 - 857
  • [32] Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience
    Kocabas, Ugur
    Duygu, Hamza
    Eren, Nihan Kahya
    Akyildiz, Zehra Ilke
    Ozyildirim, Serhan
    Tuluce, Selcen Yakar
    Kiris, Tuncay
    Nazli, Cem
    SPRINGERPLUS, 2016, 5
  • [33] Transvenous extraction of very old (over 20-year-old) pacemaker leads using mechanical systems: Effectiveness and safety
    Zabek, Andrzej
    Boczar, Krzysztof
    Debski, Maciej
    Matusik, Pawel T.
    Pfitzner, Roman
    Ulman, Mateusz
    Musial, Robert
    Lelakowski, Jacek
    Malecka, Barbara
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 998 - 1005
  • [34] One-Year Follow-Up of Patients Undergoing Transvenous Extraction of Pacemaker and Defibrillator Leads
    Kempa, Maciej
    Budrejko, Szymon
    Piepiorka-Broniecka, Marta
    Rogowski, Jan
    Kozlowski, Dariusz
    Raczak, Grzegorz
    PLOS ONE, 2015, 10 (12):
  • [35] Endocardial pacemaker or defibrillator leads with infected vegetations: A single-center experience and consequences of transvenous extraction
    Meier-Ewert, HK
    Gray, ME
    John, RM
    AMERICAN HEART JOURNAL, 2003, 146 (02) : 339 - 344
  • [36] Femoral extraction of transvenous leads and leadless pacemakers-A review of the data, tools, and procedural steps
    El-Chami, Mikhael F.
    Merchant, Faisal M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (09): : 1248 - 1252
  • [37] Transfemoral extraction of pacemaker and implantable cardioverter defibrillator leads using Needle’s Eye Snare: a single-center experience of more than 900 leads
    Xu Zhou
    Feng Ze
    Ding Li
    Long Wang
    Jiangbo Duan
    Cuizhen Yuan
    Jinshan He
    Jihong Guo
    Xuebin Li
    Heart and Vessels, 2020, 35 : 825 - 834
  • [38] Transfemoral extraction of pacemaker and implantable cardioverter defibrillator leads using Needle's Eye Snare: a single-center experience of more than 900 leads
    Zhou, Xu
    Ze, Feng
    Li, Ding
    Wang, Long
    Duan, Jiangbo
    Yuan, Cuizhen
    He, Jinshan
    Guo, Jihong
    Li, Xuebin
    HEART AND VESSELS, 2020, 35 (06) : 825 - 834
  • [39] SNARE EXTRACTION OF RIGHT VENTRICULAR PACEMAKER LEAD VIA RIGHT SUBCLAVIAN VEIN ACCESS
    Olson, Michael
    Howard, Taylor S.
    Parekh, Dhaval R.
    Lam, Wilson W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 3151 - 3151
  • [40] Recannalisation of venous occlusion, a new indication for permanent pacemaker lead extraction using a femoral approach
    Schilling, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 127A - 127A