Transvenous extraction of pacemaker leads via femoral approach using a gooseneck snare

被引:0
|
作者
Uslu, Abdulkadir [1 ]
Kup, Ayhan [1 ]
Kanar, Batur Gonenc [2 ]
Balaban, Ismail [1 ]
Demir, Serdar [1 ]
Gulsen, Kamil [1 ]
Kepez, Alper [2 ]
Dogan, Cem [1 ]
Candan, Ozkan [1 ]
Akgun, Taylan [1 ]
Altintas, Bernas [3 ]
Sadic, Beste Ozben [2 ]
机构
[1] Kartal Kosuyolu Heart & Vasc Dis Res & Training H, Cardiol Dept, Istanbul, Turkey
[2] Marmara Univ, Fac Med, Cardiol Dept, Istanbul, Turkey
[3] Gazi Yasargil Res & Training Hosp, Cardiol Dept, Diyarbakir, Turkey
关键词
Femoral vein; Endocardium; Radiofrequency ablation; Implantable cardioverter defibrillators; Cardiac pacemakers; CARDIOVERTER-DEFIBRILLATOR LEADS; LASER SHEATH; ASSOCIATION; EXPERIENCE; OUTCOMES; REMOVAL; SOCIETY; PATIENT; SAFETY;
D O I
10.1007/s00059-020-04987-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The growing problem of endocardial lead infections and leadmalfunctions has increased interest in percutaneous lead-removal technology. Transvenous lead extraction (TLE) via simple manual traction (SMT) is the first-line therapy. When SMT is not successful, TLE from the femoral vein using a gooseneck snare (GS) with a radiofrequency ablation catheter (RFAC) may be an alternative option. The aim of our study was to evaluate the success rate of transvenous extraction of chronically implanted leads via the femoral approach using a GS with RFCA in cases of failure with SMT.Methods. The study included 94 consecutive patients who were referred for lead extraction due to pocket erosion and infection (71 patients) and to lead malfunction (23 patients). Initially, SMT was attempted for all patients. If SMT was not successful, patients underwent TLE using a GS with RFAC. Results. Leads were extracted successfully with SMT in 34 patients (54 leads), while 60 patients (83 leads) underwent TLE using a GS with RFAC. The mean indwelling time of the leads was longer in the femoral approach with GS (87.5 +/- 37.9 vs. 31.3 +/- 25.8 months; p< 0.001). The procedural success rate was 96.7% in the femoral approach with GS. A preceding implantation lead duration of >51 months predicted an unsuccessful SMT necessitating alternative TLE using a GS with RFAC with 86% sensitivity and 78% specificity (p< 0.001). Conclusion. Transvenous lead extraction via the femoral approach using GS with RFAC may be an alternative approach to SMT with a high success rate, especially when the indwelling time of the leads is long.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [21] Case Report: Enhancing lead extraction techniques: a novel approach using a loop formed by an ablation catheter and a gooseneck snare
    Li, Jun
    Wang, Lei
    Li, Xiaofang
    Li, Na
    Shao, Xin
    Zhang, Anxin
    Shu, Yan
    Wang, Haixiong
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [22] Predictors and outcomes of patients requiring repeat transvenous lead extraction of pacemaker and defibrillator leads
    Claridge, Simon
    Johnson, Jonathan
    Sadnan, Gazi
    Behar, Jonathan M.
    Porter, Bradley
    Sieniewicz, Benjamin
    Jackson, Tom
    Webb, Jessica
    Gould, Justin
    Sohal, Manav
    Hamid, Shoaib
    Patel, Nik
    Gill, Jaswinder
    Rinaldi, Christopher A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (02): : 155 - 160
  • [23] Transvenous Extraction of Pacemaker Leads in Infective Endocarditis With Vegetations ≥20 mm: Our Experience
    Perez Baztarrica, Gabriel
    Gariglio, Luis
    Salvaggio, Flavio
    Reolon, Estela
    Blanco, Norberto
    Mazzetti, Hector
    Villecco, Sebastian
    Botbol, Alejandro
    Porcile, Rafael
    CLINICAL CARDIOLOGY, 2012, 35 (04) : 244 - 249
  • [24] Recannulating thrombosed veins when extracting permanent pacemaker leads using a femoral approach
    Schilling, RJ
    EUROPEAN HEART JOURNAL, 2001, 22 : 446 - 446
  • [25] Efficacy and safety of transvenous lead extraction using a liberal combined superior and femoral approach
    Sing-Chien Yap
    Rohit E. Bhagwandien
    Dominic A. M. J. Theuns
    Yunus Emre Yasar
    John de Heide
    Mark G. Hoogendijk
    Charles Kik
    Tamas Szili-Torok
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 239 - 248
  • [26] Efficacy and safety of transvenous lead extraction using a liberal combined superior and femoral approach
    Yap, Sing-Chien
    Bhagwandien, Rohit E.
    Theuns, Dominic A. M. J.
    Yasar, Yunus Emre
    de Heide, John
    Hoogendijk, Mark G.
    Kik, Charles
    Szili-Torok, Tamas
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (02) : 239 - 248
  • [27] The femoral approach as adjunctive strategy during transvenous lead extraction
    Wazni, O.
    Nakhla, S.
    Tarakji, K.
    Barakat, A.
    Saliba, W.
    Rickard, J.
    Callahan, T.
    Martin, D.
    Kanj, M.
    Baranowski, B.
    Cantillon, D.
    Niebauer, M.
    Lindsay, B.
    Wilkoff, B.
    Hussein, A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1026 - 1026
  • [28] The role of transvenous lead extraction in the management of redundant or malfunctioning pacemaker and defibrillator leads post ELECTRa
    Sidhu, Baldeep S.
    Gould, Justin
    Sieniewicz, Benjamin
    Porter, Bradley
    Rinaldi, Christopher A.
    EUROPACE, 2018, 20 (11): : 1733 - 1740
  • [29] Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads-A Single-Center Experience
    Akcay, Murat
    Yuksel, Serkan
    MEDICINA-LITHUANIA, 2024, 60 (08):
  • [30] Transvenous embolisation of an arteriovenous malformation of the mandible via a femoral approach
    F. J. A. Beek
    Frans W. ten Broek
    Jan P. J. van Schaik
    Willem P. T. M. Mali
    Pediatric Radiology, 1997, 27 : 855 - 857