Long-term comparison of everolimus-eluting and biolimus-eluting stents

被引:10
|
作者
Puricel, Serban [1 ]
Oberhaensli, Markus [1 ]
Guntern, Patricia [1 ]
Lehmann, Sonja [1 ]
Goy, Jean-Jacques [1 ]
Arroyo, Diego [1 ]
Villeneuve, Helene [1 ]
Baeriswyl, Gerard [1 ]
Stauffer, Jean-Christophe [1 ]
Togni, Mario [1 ]
Cook, Stephane [1 ]
机构
[1] Univ Hosp, Dept Cardiol, Fribourg, Switzerland
关键词
drug-eluting stent; percutaneous coronary intervention; stent thrombosis; PERCUTANEOUS CORONARY INTERVENTION; BIODEGRADABLE POLYMER; FOLLOW-UP; DURABLE POLYMER; POOLED ANALYSIS; TRIAL; OUTCOMES; REVASCULARIZATION; THROMBOSIS; REDUCE;
D O I
10.4244/EIJV9I3A55
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients. Methods and results: A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (1112. 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (ER 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0). Conclusions: This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES).
引用
收藏
页码:336 / 344
页数:9
相关论文
共 50 条
  • [31] Two-year clinical outcomes of the NOBORI biolimus-eluting stents versus XIENCE/PROMUS everolimus-eluting stents in small vessel disease
    Jinnouchi, Hiroyuki
    Kuramitsu, Shoichi
    Shinozaki, Tomohiro
    Hiromasa, Takashi
    Kobayashi, Yohei
    Morinaga, Takashi
    Yamaji, Kyohei
    Soga, Yoshimitsu
    Shirai, Shinichi
    Ando, Kenji
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (05) : E132 - E138
  • [32] VASCULAR RESPONSE TO EVEROLIMUS AND BIOLIMUS-ELUTING CORONARY STENTS VERSUS EVEROLIMUS-ELUTING BIORESORBABLE SCAFFOLDS: AN OPTICAL COHERENCE TOMOGRAPHY SUBSTUDY OF THE EVERBIO II TRIAL
    Kallinikou, Zacharenia
    Puricel, Serban
    Lehmann, Sonja
    Arroyo, Diego
    Togni, Mario
    Cook, Malica
    Baeriswyl, Gerard
    Stauffer, Jean-hristophe
    Goy, Jean-Jacques
    Cook, Stephane
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1763 - A1763
  • [33] Comparison of Zotarolimus-Eluting and Everolimus-Eluting Coronary Stents
    Serruys, Patrick W.
    Silber, Sigmund
    Garg, Scot
    van Geuns, Robert Jan
    Richardt, Gert
    Buszman, Pawel E.
    Kelbaek, Henning
    van Boven, Adrianus Johannes
    Hofma, Sjoerd H.
    Linke, Axel
    Klauss, Volker
    Wijns, William
    Macaya, Carlos
    Garot, Philippe
    DiMario, Carlo
    Manoharan, Ganesh
    Kornowski, Ran
    Ischinger, Thomas
    Bartorelli, Antonio
    Ronden, Jacintha
    Bressers, Marco
    Gobbens, Pierre
    Negoita, Manuela
    van Leeuwen, Frank
    Windecker, Stephan
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (02): : 136 - 146
  • [34] Comparative safety and effectiveness of polymer-free biolimus-eluting stents versus permanent-polymer everolimus-eluting stents in routine clinical practice
    Giordano, Arturo
    Ferraro, Paolo
    Corcione, Nicola
    Pieri, Pietro
    Mancone, Massimo
    Sardella, Gennaro
    Biondi-Zoccai, Giuseppe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B249 - B249
  • [35] OPTICAL COHERENCE TOMOGRAPHY ASSESSMENT FOR BIOLIMUS-ELUTING STENT AND EVEROLIMUS-ELUTING STENT IN THE VERY EARLY PERIOD
    Kuramitsu, Shoichi
    Iwabuchi, Masashi
    Domei, Takenori
    Haraguchi, Takuya
    Nagae, Ayumu
    Kazuno, Yoshio
    Enomoto, Soichiro
    Mazaki, Toru
    Hyodo, Makoto
    Soga, Yoshimitsu
    Shirai, Shinichi
    Takabatake, Yoshitaka
    Yokoi, Hiroyoshi
    Toyota, Fumitoshi
    Nobuyoshi, Masakiyo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E146 - E146
  • [36] Long-term comparative effectiveness of Endeavor zotarolimus-eluting and everolimus-eluting stents in New York
    Qian, Feng
    Zhong, Ye
    Hannan, Edward L.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 241 : 437 - 443
  • [37] Vascular response to everolimus- and biolimus-eluting coronary stents versus everolimus-eluting bioresorbable scaffolds - an optical coherence tomography substudy of the EVERBIO II trial
    Kallinikou, Zacharenia
    Arroyo, Diego
    Togni, Mario
    Lehmann, Sonja
    Corpataux, Noe
    Cook, Malica
    Mueller, Olivier
    Baeriswyl, Gerard
    Stauffer, Jean-Christophe
    Goy, Jean-Jacques
    Puricel, Serban
    Cook, Stephane
    SWISS MEDICAL WEEKLY, 2016, 146 : w14274
  • [38] Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stents
    Shah, Rahman
    ANNALS OF INTERNAL MEDICINE, 2016, 165 (11) : 828 - 829
  • [39] Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents
    Sorrentino, Sabato
    Giustino, Gennaro
    Mehran, Roxana
    Kini, Anapoorna S.
    Sharma, Samin K.
    Faggioni, Michela
    Farhan, Serdar
    Vogel, Birgit
    Indolfi, Ciro
    Dangas, George D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (25) : 3055 - 3066
  • [40] Meta-Analysis of Long-Term Clinical Outcomes of Everolimus-Eluting Stents
    Toyota, Toshiaki
    Shiomi, Hiroki
    Morimoto, Takeshi
    Kimura, Takeshi
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (02): : 187 - 194