Long-term comparison of everolimus-eluting and biolimus-eluting stents

被引:10
|
作者
Puricel, Serban [1 ]
Oberhaensli, Markus [1 ]
Guntern, Patricia [1 ]
Lehmann, Sonja [1 ]
Goy, Jean-Jacques [1 ]
Arroyo, Diego [1 ]
Villeneuve, Helene [1 ]
Baeriswyl, Gerard [1 ]
Stauffer, Jean-Christophe [1 ]
Togni, Mario [1 ]
Cook, Stephane [1 ]
机构
[1] Univ Hosp, Dept Cardiol, Fribourg, Switzerland
关键词
drug-eluting stent; percutaneous coronary intervention; stent thrombosis; PERCUTANEOUS CORONARY INTERVENTION; BIODEGRADABLE POLYMER; FOLLOW-UP; DURABLE POLYMER; POOLED ANALYSIS; TRIAL; OUTCOMES; REVASCULARIZATION; THROMBOSIS; REDUCE;
D O I
10.4244/EIJV9I3A55
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients. Methods and results: A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (1112. 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (ER 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0). Conclusions: This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES).
引用
收藏
页码:336 / 344
页数:9
相关论文
共 50 条
  • [11] Safety and efficacy of second generation everolimus-eluting stents versus biolimus-eluting stents versus zotarolimus-eluting stents in real world practice
    Ki, Y. J.
    Park, K. W.
    Kang, J. H.
    Kim, C. H.
    Han, J. K.
    Yang, H. M.
    Kang, H. J.
    Koo, B. K.
    Kim, H. S.
    EUROPEAN HEART JOURNAL, 2018, 39 : 325 - 325
  • [12] Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography
    Tada, Tomohisa
    Kastrati, Adnan
    Byrne, Robert A.
    Schuster, Tibor
    Cuni, Rezarta
    King, Lamin A.
    Cassese, Salvatore
    Joner, Michael
    Pache, Jurgen
    Massberg, Steffen
    Schoemig, Albert
    Mehilli, Julinda
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (03): : 495 - 504
  • [13] Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with coronary artery disease: three-year follow-up of the COMPARE II (Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent) trial
    Vlachojannis, Georgios J.
    Smits, Pieter C.
    Hofma, Sjoerd H.
    Togni, Mario
    Vazquez, Nicolas
    Valdes, Mariano
    Voudris, Vassilis
    Puricel, Serban
    Slagboom, Ton
    Goy, Jean-Jacques
    den Heijer, Peter
    van der Ent, Martin
    EUROINTERVENTION, 2015, 11 (03) : 272 - 279
  • [14] Long-term comparison of everolimus-eluting stents with sirolimus-eluting stents for saphenous vein graft intervention
    Taniwaki, M.
    Raber, L.
    Kalesan, B.
    Magro, M.
    Stefanini, G.
    Van Domburg, R.
    Wenaweser, P.
    Juni, P.
    Serruys, P.
    Windecker, S.
    EUROPEAN HEART JOURNAL, 2012, 33 : 384 - 384
  • [15] Comparison of the Safety and Efficacy of Biodegradable Polymer Biolimus-Eluting Stents and Durable Polymer Everolimus-Eluting Stents: Propensity Score-Matched Analysis
    Lee, Ji Hyun
    Lee, Jun-Won
    Youn, Young Jin
    Ahn, Min Soo
    Ahn, Sung Gyun
    Kim, Jang Young
    Yoo, Byung-Su
    Lee, Seung-Hwan
    Choi, Eunhee
    Yoon, Junghan
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (04) : 399 - 407
  • [16] Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention
    Maeng, Michael
    Christiansen, Evald Hoj
    Raungaard, Bent
    Kahlert, Johnny
    Terkelsen, Christian Juhl
    Kristensen, Steen Dalby
    Carstensen, Steen
    Aaroe, Jens
    Jensen, Svend Eggert
    Villadsen, Anton Boel
    Lassen, Jens Flensted
    Thim, Troels
    Eftekhari, Ashkan
    Veien, Karsten Tange
    Hansen, Knud Norregaard
    Junker, Anders
    Botker, Hans Erik
    Jensen, Lisette Okkels
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (07) : 624 - 633
  • [17] Long-term Comparison Everolimus-Eluting Stents With Sirolimus-Eluting Stents in Patients With Acute Coronary Syndromes
    Raber, Lorenz
    Juni, Peter
    Kalesan, Bindu
    Wenaweser, Peter
    Cook, Stephane
    Togni, Mario
    Vogel, Rolf
    Nuesch, Eveline
    Christian, Seiler
    Meier, Bernhard
    Windecker, Stephan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B65 - B65
  • [18] Biolimus-eluting versus everolimus-eluting stents in coronary artery disease: a pooled analysis from the NEXT (NOBORI biolimus-eluting versus XIENCE/PROMUS everolimus-eluting stent) and COMPARE II (Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimuseluting stent) randomised trials
    Vlachojannisi, Georgios J.
    Puricel, Serban
    Natsuaki, Masahiro
    Morimoto, Takeshi
    Smits, Picier C.
    Kimura, Takeshi
    EUROINTERVENTION, 2017, 12 (16) : 1970 - 1977
  • [19] Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography
    Tomohisa Tada
    Adnan Kastrati
    Robert A. Byrne
    Tibor Schuster
    Rezarta Cuni
    Lamin A. King
    Salvatore Cassese
    Michael Joner
    Jürgen Pache
    Steffen Massberg
    Albert Schömig
    Julinda Mehilli
    The International Journal of Cardiovascular Imaging, 2014, 30 : 495 - 504
  • [20] Five-year angiographic, OCT and clinical outcomes of a randomized comparison of everolimus and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds
    Schukraft, Sara
    Arroyo, Diego
    Togni, Mario
    Goy, Jean-Jacques
    Wenaweser, Peter
    Stadelmann, Mathieu
    Baeriswyl, Gerard
    Muller, Olivier
    Stauffer, Jean-Christophe
    Puricel, Serban
    Cook, Stephane
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (03) : 523 - 532