A method for calibrating the CT-based attenuation correction of PET in human tissue

被引:20
|
作者
Watson, CC [1 ]
Rappoport, V
Faul, D
Townsend, DW
Carney, JP
机构
[1] Siemens Mol Imaging, Knoxville, TN 37932 USA
[2] Univ Tennessee, Med Ctr, Knoxville, TN 37920 USA
[3] Univ Pittsburgh, Med Ctr, Pittsburgh, PA 15213 USA
关键词
attenuation correction; human tissue; linear attenuation coefficient; PET; PET/CT;
D O I
10.1109/TNS.2005.862972
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of x-ray computed tomography (CT)-based attenuation correction for positron emission tomography (PET) in PET/CT systems requires the transformation of CT Hounsfield units (HU) to linear attenuation coefficients at 511 keV (LAC(511)). This cannot be done perfectly from a single peak kilovolt (kVp) CT scan due to variability in Compton and photoelectric composition and, thus, an approximate transformation must be employed. One difficulty in this lies in accurately determining the linear attenuation coefficients (LAC) in actual human tissue. Typically, phantoms consisting of synthetic materials thought to be approximate human tissue equivalents are employed instead. A potentially more accurate approach would be to use dual kVp CT scans to estimate LAC511 in actual human tissue and then base the single kVp transformation on these data. This approach would also permit an assessment of the dispersion of actual tissue values about the two-component trend lines typically used for the single kVp transformation. In this paper, we develop and assess this methodology.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 50 条
  • [41] CT-based Evaluation of Segmented Head Regions for Attenuation Correction in MR-PET Systems
    Wagenknecht, Gudrun
    Kops, Elena Rota
    Kaffanke, Joachim
    Tellmann, Lutz
    Mottaghy, Felix
    Piroth, Marc D.
    Herzog, Hans
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2793 - 2797
  • [42] A Novel Approach for Reducing Dental Filling Artifact in CT-Based Attenuation Correction of PET Data
    Abdoli, M.
    Ay, M. R.
    Ahmadian, A.
    Sahba, N.
    Zaidi, H.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 492 - 495
  • [43] Metal Artifact Reduction in CT-Based Attenuation Correction of PET using Sobolev Sinogram Restoration
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2936 - 2942
  • [44] Use of tube current modulation to minimize radiation dose in CT-based PET attenuation correction
    Turkington, Timothy
    Lokitz, Stephen
    Colsher, James
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [45] PET/MRI for RT planning: CT-based attenuation correction of radiation treatment positioning devices
    Taeubert, L.
    Berker, Y.
    Beuthien-Baumann, B.
    Hoffmann, A. L.
    Troost, E. G. C.
    Pfaffenberger, A.
    Kachelriess, M.
    Gillmann, C.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S969 - S969
  • [46] Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm
    Ahmadian, Alireza
    Ay, Mohammad R.
    Bidgoli, Javad H.
    Sarkar, Saeed
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (10) : 1812 - 1823
  • [47] Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm
    Bidgoli, J. H.
    Sarkar, S.
    Alunadian, A.
    Zaidi, H.
    Reza, Mohammad
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3542 - +
  • [48] Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm
    Alireza Ahmadian
    Mohammad R. Ay
    Javad H. Bidgoli
    Saeed Sarkar
    Habib Zaidi
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35
  • [49] Dual-modality PET/CT imaging: CT-based attenuation correction in the presence of CT contrast agents.
    Beyer, T
    Townsend, DW
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 56P - 56P
  • [50] Effects of CT-based attenuation correction on quantitative SPECT/CT of jawbone
    Tsuchitani, Tatsuya
    Kitajima, Kazuhiro
    Takahashi, Yoshiyuki
    Yoshida, Rika
    Kiada, Hayato
    Tsurusaki, Masakatsu
    Minami, Tetsuya
    Kotura, Noriko
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 (02) : 108 - 113