A method for calibrating the CT-based attenuation correction of PET in human tissue

被引:20
|
作者
Watson, CC [1 ]
Rappoport, V
Faul, D
Townsend, DW
Carney, JP
机构
[1] Siemens Mol Imaging, Knoxville, TN 37932 USA
[2] Univ Tennessee, Med Ctr, Knoxville, TN 37920 USA
[3] Univ Pittsburgh, Med Ctr, Pittsburgh, PA 15213 USA
关键词
attenuation correction; human tissue; linear attenuation coefficient; PET; PET/CT;
D O I
10.1109/TNS.2005.862972
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of x-ray computed tomography (CT)-based attenuation correction for positron emission tomography (PET) in PET/CT systems requires the transformation of CT Hounsfield units (HU) to linear attenuation coefficients at 511 keV (LAC(511)). This cannot be done perfectly from a single peak kilovolt (kVp) CT scan due to variability in Compton and photoelectric composition and, thus, an approximate transformation must be employed. One difficulty in this lies in accurately determining the linear attenuation coefficients (LAC) in actual human tissue. Typically, phantoms consisting of synthetic materials thought to be approximate human tissue equivalents are employed instead. A potentially more accurate approach would be to use dual kVp CT scans to estimate LAC511 in actual human tissue and then base the single kVp transformation on these data. This approach would also permit an assessment of the dispersion of actual tissue values about the two-component trend lines typically used for the single kVp transformation. In this paper, we develop and assess this methodology.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 50 条
  • [1] A method for calibrating the CT-based attenuation correction of PET in human tissue
    Watson, CC
    Rappoport, V
    Faul, D
    Townsend, DW
    Carney, JP
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3487 - 3491
  • [2] Method for discrimination of contrast media in CT-based PET attenuation correction.
    Laymon, CM
    Carney, J
    Townsend, D
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 273P - 274P
  • [3] Automated CT-based Attenuation Correction for Preclinical Multimodality PET/CT
    Chen, Mu
    Osborne, Dustin
    Gleason, Shaun
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4043 - +
  • [4] Accuracy of CT-based attenuation correction in PET/CT bone imaging
    Abella, Monica
    Alessio, Adam M.
    Mankoff, David A.
    MacDonald, Lawrence R.
    Jose Vaquero, Juan
    Desco, Manuel
    Kinahan, Paul E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [5] Accuracy of CT-Based attenuation correction in bone Imaging with PET/CT
    Abella, M.
    Mankof, D.
    Vaquero, J. J.
    Desco, M.
    Kinahan, P. E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4485 - +
  • [6] Effect of different Chemoembolization materials on CT-based PET attenuation correction in PET/CT
    Heusner, T. A.
    Fronz, U.
    Jentzen, W.
    Verhagen, R.
    Bockisch, A.
    Antoch, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S151 - S151
  • [7] The effect of different chemoembolization materials on CT-based attenuation correction in PET/CT
    Heusner, T. -A.
    Fronz, U.
    Jentzen, W.
    Verhagen, R.
    Forsting, M.
    Bockisch, A.
    Antoch, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (11): : 1159 - 1165
  • [8] CT-Based Attenuation Correction on the FLEX Triumph Preclinical PET/CT Scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 66 - 75
  • [9] CT-Based attenuation correction for PET/CT scanners in the presence of contrast agent
    Carney, J
    Beyer, T
    Brasse, D
    Yap, JT
    Townsend, DW
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1443 - 1446
  • [10] CT-based attenuation correction on the FLEX Triumph™ preclinical PET/CT scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3357 - +