Heart Rate Variability and Extubation Readiness in Extremely Preterm Infants

被引:39
|
作者
Kaczmarek, Jennifer [1 ]
Chawla, Sanjay [3 ]
Marchica, Cinzia [2 ]
Dwaihy, Meghan [2 ]
Grundy, Linda [2 ]
Sant'Anna, Guilherme Mendes [1 ]
机构
[1] McGill Univ, Dept Pediat, Div Neonatol, Montreal, PQ H3A 2T5, Canada
[2] Univ Montreal, Sch Med, Montreal, PQ H3C 3J7, Canada
[3] Wayne State Univ, Dept Pediat, Div Neonatol, Detroit, MI 48202 USA
关键词
Heart rate variability; Extubation readiness; Extubation failure; Clinical predictors; BIRTH-WEIGHT INFANTS; SPECTRAL-ANALYSIS; VENTILATION; MORTALITY; SLEEP; CPAP;
D O I
10.1159/000347101
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Mechanical ventilation (MV) is associated with changes in autonomic nervous system activity in preterm infants, which can be assessed by measurements of heart rate variability (HRV). Decreased HRV has been described in adults undergoing disconnection from MV; such information is not available in preterm infants. Objective: To compare differences in HRV between infants successfully extubated and those who failed, and to evaluate the accuracy of HRV as a predictor of extubation readiness. Methods: This is a prospective, observational study of infants with a birth weight <= 1,250 g undergoing their first extubation attempt. Heart rate was measured during a 60-min period immediately prior to extubation and HRV was calculated using the frequency domain analysis. Results: A total of 47 infants were studied; 36 were successfully extubated and 11 reintubated. There were no differences in patient demographics, ventilator settings, blood gases or postextubation management between the groups. All components of the HRV analysis were significantly decreased in infants who failed, generating high areas under the receiver operating characteristic curve. The specificity and positive predictive values were 100, but with limited sensitivity and negative predictive values. Conclusions: Infants considered 'ready to be extubated' but who subsequently failed their first extubation attempt had decreased HRV prior to extubation. Though promising, the value of HRV as a predictor of extubation readiness requires further evaluation. Copyright (c) 2013 S. Karger AG, Basel
引用
收藏
页码:42 / 48
页数:7
相关论文
共 50 条
  • [31] Surface electromyography for analysis of heart rate variability in preterm infants
    Jost, Kerstin
    Scherer, Sebastian
    De Angelis, Chiara
    Buchler, Marcel
    Datta, Alexandre N.
    Cattin, Philippe C.
    Frey, Urs
    Suki, Bela
    Schulzke, Sven M.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (01)
  • [32] CONTINUOUS MONITORING OF HEART-RATE-VARIABILITY IN PRETERM INFANTS
    PRIETSCH, V
    KNOEPKE, U
    OBLADEN, M
    EARLY HUMAN DEVELOPMENT, 1994, 37 (02) : 117 - 131
  • [33] The effect of atropine on heart rate variability (HRV) in preterm infants
    Andriessen, P
    Berendsen, RCM
    Antonius, T
    Oei, SG
    Wijn, PFF
    Blanco, CE
    PEDIATRIC RESEARCH, 2002, 52 (05) : 793 - 793
  • [34] Erratum: The effect of massage on heart rate variability in preterm infants
    S L Smith
    R Lux
    S Haley
    H Slater
    J Beachy
    L J Moyer-Mileur
    Journal of Perinatology, 2013, 33 : 250 - 250
  • [35] Assessment of Extubation Readiness Using Spontaneous Breathing Trials in Extremely Preterm Neonates
    Shalish, Wissam
    Kanbar, Lara
    Kovacs, Lajos
    Chawla, Sanjay
    Keszler, Martin
    Rao, Smita
    Latremouille, Samantha
    Precup, Doina
    Brown, Karen
    Kearney, Robert E.
    Sant'Anna, Guilherme M.
    JAMA PEDIATRICS, 2020, 174 (02) : 178 - 185
  • [36] Predicting Extubation Readiness in Extreme Preterm Infants based on Patterns of Breathing
    Onu, Charles C.
    Kanbar, Lara J.
    Shalish, Wissam
    Brown, Karen A.
    Sant'Anna, Guilherme M.
    Kearney, Robert E.
    Precup, Doina
    2017 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (SSCI), 2017, : 355 - 361
  • [37] Extubation Readiness in Preterm Infants: Evaluating the Role of Monitoring Intermittent Hypoxemia
    Abu Jawdeh, Elie G.
    Pant, Amrita
    Gabrani, Aayush
    Cunningham, M. Douglas
    Raffay, Thomas M.
    Westgate, Philip M.
    CHILDREN-BASEL, 2021, 8 (03):
  • [38] Development and validation of a prediction model for evaluating extubation readiness in preterm infants
    Song, Wongeun
    Jung, Young Hwa
    Cho, Jihoon
    Baek, Hyunyoung
    Choi, Chang Won
    Yoo, Sooyoung
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2023, 178
  • [39] Heart Rate Variability In Extremely Preterm Infants While Receiving Nasal Intermittent Positive Pressure Ventilation (nippv) And Continuous Positive Airway Pressure (cpap) Immediately After Extubation
    Latremouille, S.
    Kanbar, L.
    Lamer, P.
    Al-Jabri, A.
    Shalish, W.
    Kearney, R.
    Sant'Anna, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [40] A randomized trial of delayed extubation for the reduction of reintubation in extremely preterm infants
    Danan, Claude
    Durrmeyer, Xavier
    Brochard, Laurent
    Decobert, Fabrice
    Benani, Mohamed
    Dassieu, Gilles