Heart Rate Variability and Extubation Readiness in Extremely Preterm Infants

被引:39
|
作者
Kaczmarek, Jennifer [1 ]
Chawla, Sanjay [3 ]
Marchica, Cinzia [2 ]
Dwaihy, Meghan [2 ]
Grundy, Linda [2 ]
Sant'Anna, Guilherme Mendes [1 ]
机构
[1] McGill Univ, Dept Pediat, Div Neonatol, Montreal, PQ H3A 2T5, Canada
[2] Univ Montreal, Sch Med, Montreal, PQ H3C 3J7, Canada
[3] Wayne State Univ, Dept Pediat, Div Neonatol, Detroit, MI 48202 USA
关键词
Heart rate variability; Extubation readiness; Extubation failure; Clinical predictors; BIRTH-WEIGHT INFANTS; SPECTRAL-ANALYSIS; VENTILATION; MORTALITY; SLEEP; CPAP;
D O I
10.1159/000347101
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Mechanical ventilation (MV) is associated with changes in autonomic nervous system activity in preterm infants, which can be assessed by measurements of heart rate variability (HRV). Decreased HRV has been described in adults undergoing disconnection from MV; such information is not available in preterm infants. Objective: To compare differences in HRV between infants successfully extubated and those who failed, and to evaluate the accuracy of HRV as a predictor of extubation readiness. Methods: This is a prospective, observational study of infants with a birth weight <= 1,250 g undergoing their first extubation attempt. Heart rate was measured during a 60-min period immediately prior to extubation and HRV was calculated using the frequency domain analysis. Results: A total of 47 infants were studied; 36 were successfully extubated and 11 reintubated. There were no differences in patient demographics, ventilator settings, blood gases or postextubation management between the groups. All components of the HRV analysis were significantly decreased in infants who failed, generating high areas under the receiver operating characteristic curve. The specificity and positive predictive values were 100, but with limited sensitivity and negative predictive values. Conclusions: Infants considered 'ready to be extubated' but who subsequently failed their first extubation attempt had decreased HRV prior to extubation. Though promising, the value of HRV as a predictor of extubation readiness requires further evaluation. Copyright (c) 2013 S. Karger AG, Basel
引用
收藏
页码:42 / 48
页数:7
相关论文
共 50 条
  • [21] Cardiorespiratory measures shortly after extubation and extubation outcomes in extremely preterm infants
    Latremouille, Samantha
    Bhuller, Monica
    Shalish, Wissam
    Sant'Anna, Guilherme
    PEDIATRIC RESEARCH, 2023, 93 (06) : 1687 - 1693
  • [22] Predicting extubation readiness in preterm infants using machine learning
    Brasher, M.
    Wirian, Y.
    Raffay, T. M.
    Bada, H.
    Cunningham, M. D.
    Cheng, Q.
    Abu Jawdeh, E. G.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2023, 365 : S272 - S272
  • [23] Prediction of extubation readiness using lung ultrasound in preterm infants
    Soliman, Reem M.
    Elsayed, Yasser
    Said, Reem N.
    Abdulbaqi, Abdulaziz M.
    Hashem, Rania H.
    Aly, Hany
    PEDIATRIC PULMONOLOGY, 2021, 56 (07) : 2073 - 2080
  • [24] Bedside Lung Ultrasound As A Predictor Of The Extubation Readiness In Preterm Infants
    Samedi, Veronica M.
    Kalaniti, Kaarthigeyan
    Daspal, Sibasis
    PEDIATRICS, 2021, 147 (03)
  • [25] Can a predictive model for extubation readiness in preterm infants improve rates of successful extubation?
    Shay, Rebecca
    Wright, Clyde J.
    ACTA PAEDIATRICA, 2021, 110 (02) : 722 - 723
  • [26] Respiratory setback associated with extubation failure in extremely preterm infants
    Gupta, Dhruv
    Greenberg, Rachel G.
    Natarajan, Girija
    Jani, Sanket
    Sharma, Amit
    Cotten, Michael
    Thomas, Ronald
    Chawla, Sanjay
    PEDIATRIC PULMONOLOGY, 2021, 56 (07) : 2081 - 2086
  • [27] The effects of nasal continuous positive airway pressure and high flow nasal cannula on heart rate variability in extremely preterm infants after extubation: A randomized crossover trial
    Latremouille, Samantha
    Shalish, Wissam
    Kanbar, Lara
    Lamer, Philippe
    Rao, Smita
    Kearney, Robert E.
    Sant'Anna, Guilherme M.
    PEDIATRIC PULMONOLOGY, 2019, 54 (06) : 788 - 796
  • [28] Interaction between Heart Rate Variability and Respiration in Preterm Infants
    Indic, P.
    Salisbury, E. B.
    Paydarfar, D.
    Brown, E. N.
    Barbieri, R.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 57 - +
  • [29] Development of baroreflex influences on heart rate variability in preterm infants
    Mazursky, JE
    Birkett, CL
    Bedell, KA
    Ben-Haim, SA
    Segar, JL
    EARLY HUMAN DEVELOPMENT, 1998, 53 (01) : 37 - 52
  • [30] FACTORS AFFECTING HEART-RATE-VARIABILITY IN PRETERM INFANTS
    CABAL, LA
    SIASSI, B
    ZANINI, B
    HODGMAN, JE
    HON, EE
    PEDIATRICS, 1980, 65 (01) : 50 - 56