Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke

被引:22
|
作者
Stookey, Alyssa D. [1 ]
McCusker, Michael G. [2 ]
Sorkin, John D. [1 ,2 ]
Katzel, Leslie I. [1 ,2 ]
Shaughnessy, Marianne [1 ,2 ]
Macko, Richard F. [1 ,2 ]
Ivey, Frederick M. [1 ,2 ]
机构
[1] Baltimore VA Med Ctr, Baltimore, MD USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
gait economy; oxygen consumption; hemiparesis; 6-MINUTE WALK; INDIVIDUALS; EXERCISE; FITNESS; GAIT; IMPAIRMENTS; DISTANCE; MILD;
D O I
10.1177/1545968313497103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. Impaired economy of gait, prevalent in chronic stroke secondary to residual gait deficits, is associated with intolerance for performing activities of daily living. Gait economy/efficiency is traditionally assessed by determining the rate of oxygen consumption during submaximal treadmill walking. However, the mechanics and energetics of treadmill versus overground walking are very different in stroke survivors with ambulatory deficits. Clearly, overground cardiopulmonary measures are needed to accurately profile movement economy after stroke. An obstacle to obtaining such measures after stroke has been the absence of reliable portable metabolic monitoring equipment. The purpose of this study was to establish the test-retest reliability of a portable metabolic monitoring device during overground walking in hemiparetic stroke survivors. Methods. Twenty-three chronic hemiparetic stroke survivors underwent two 6-minute walk tests while wearing a COSMED K4b(2) portable metabolic measurement system. Intraclass correlations coefficients (ICC) were calculated for both cardiopulmonary parameters and distance covered to determine test-retest reliability. An ICC of 0.85 was considered reliable. Results. ICCs for relative Vo(2) (0.90), absolute Vo(2) (0.93), Vco(2) (0.93), and minute ventilation (0.95) demonstrated high reliability, but not for heart rate (0.76) or respiratory exchange ratio (0.64). There was no significant difference in the distance each participant walked between the first and second tests, eliminating distance as a potential confounder of our analyses (ICC = 0.99). Conclusions. Our results strongly support the reliability of the K4b(2) for quantifying overground gait efficiency after stroke. Use of this device may enable researchers to study how varying poststroke rehabilitation interventions affect this central measure of health and function.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 50 条
  • [31] Cluster analysis for test-retest Reliability
    Roy, Debdulal Dutta
    INTERNATIONAL JOURNAL OF PSYCHOLOGICAL RESEARCH, 2010, 3 (01): : 131 - 139
  • [32] THE TEST-RETEST RELIABILITY OF QUALITATIVE DATA
    Guttman, Louis
    PSYCHOMETRIKA, 1946, 11 (02) : 81 - 95
  • [33] Test-retest reliability of functional MRI
    Tallent, KA
    Ramsey, NF
    Frank, JA
    Moonen, CT
    Weinberger, DR
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 12451 - 12451
  • [34] An Investigation of the Test-Retest Reliability of the miniPXI
    Haider, Aqeel
    Wallner, Günter
    Gerling, Kathrin
    Vanden Abeele, Vero
    Proceedings of the ACM on Human-Computer Interaction, 2024, 8 (CHI PLAY)
  • [35] SKEW REDUCES TEST-RETEST RELIABILITY
    DUNLAP, WP
    CHEN, RS
    GREER, T
    JOURNAL OF APPLIED PSYCHOLOGY, 1994, 79 (02) : 310 - 313
  • [36] A BASIS FOR ANALYZING TEST-RETEST RELIABILITY
    Guttman, Louis
    PSYCHOMETRIKA, 1945, 10 (04) : 255 - 282
  • [37] Test-retest reliability in Electroencephalographic Recordings
    Ximena Suarez-Revelo, Jazmin
    Fredy Ochoa-Gomez, John
    Duque-Grajales, Jon
    Montoya-Betancur, Alejandro
    Sanchez-Lopez, Sebastian
    2015 20TH SYMPOSIUM ON SIGNAL PROCESSING, IMAGES AND COMPUTER VISION (STSIVA), 2015,
  • [38] Test-retest reliability of loudness scaling
    Robinson, K
    Gatehouse, S
    EAR AND HEARING, 1996, 17 (02): : 120 - 123
  • [39] TEST-RETEST RELIABILITY OF THE IDEA INVENTORY
    VESTRE, ND
    PSYCHOLOGICAL REPORTS, 1984, 54 (03) : 873 - 874
  • [40] Test of Everyday Attention in patients with chronic stroke: Test-retest reliability and practice effects
    Chen, Hui-Chun
    Koh, Chia-Lin
    Hsieh, Ching-Lin
    Hsueh, I-Ping
    BRAIN INJURY, 2013, 27 (10) : 1148 - 1154