Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke

被引:22
|
作者
Stookey, Alyssa D. [1 ]
McCusker, Michael G. [2 ]
Sorkin, John D. [1 ,2 ]
Katzel, Leslie I. [1 ,2 ]
Shaughnessy, Marianne [1 ,2 ]
Macko, Richard F. [1 ,2 ]
Ivey, Frederick M. [1 ,2 ]
机构
[1] Baltimore VA Med Ctr, Baltimore, MD USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
gait economy; oxygen consumption; hemiparesis; 6-MINUTE WALK; INDIVIDUALS; EXERCISE; FITNESS; GAIT; IMPAIRMENTS; DISTANCE; MILD;
D O I
10.1177/1545968313497103
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. Impaired economy of gait, prevalent in chronic stroke secondary to residual gait deficits, is associated with intolerance for performing activities of daily living. Gait economy/efficiency is traditionally assessed by determining the rate of oxygen consumption during submaximal treadmill walking. However, the mechanics and energetics of treadmill versus overground walking are very different in stroke survivors with ambulatory deficits. Clearly, overground cardiopulmonary measures are needed to accurately profile movement economy after stroke. An obstacle to obtaining such measures after stroke has been the absence of reliable portable metabolic monitoring equipment. The purpose of this study was to establish the test-retest reliability of a portable metabolic monitoring device during overground walking in hemiparetic stroke survivors. Methods. Twenty-three chronic hemiparetic stroke survivors underwent two 6-minute walk tests while wearing a COSMED K4b(2) portable metabolic measurement system. Intraclass correlations coefficients (ICC) were calculated for both cardiopulmonary parameters and distance covered to determine test-retest reliability. An ICC of 0.85 was considered reliable. Results. ICCs for relative Vo(2) (0.90), absolute Vo(2) (0.93), Vco(2) (0.93), and minute ventilation (0.95) demonstrated high reliability, but not for heart rate (0.76) or respiratory exchange ratio (0.64). There was no significant difference in the distance each participant walked between the first and second tests, eliminating distance as a potential confounder of our analyses (ICC = 0.99). Conclusions. Our results strongly support the reliability of the K4b(2) for quantifying overground gait efficiency after stroke. Use of this device may enable researchers to study how varying poststroke rehabilitation interventions affect this central measure of health and function.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 50 条
  • [21] How to assess test-retest reliability of a test?
    Schuck, P
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 2000, 35 (3-4) : 318 - 318
  • [22] Test-retest reliability of willingness to pay
    Alan Shiell
    Penelope Hawe
    The European Journal of Health Economics, 2006, 7 (3) : 173 - 178
  • [23] TEST-RETEST RELIABILITY IN LONGITUDINAL RESEARCH
    RYAN, CM
    JOURNAL OF CLINICAL AND EXPERIMENTAL NEUROPSYCHOLOGY, 1985, 7 (06) : 630 - 630
  • [24] THE TEST-RETEST RELIABILITY OF THE PROGRESSIVE MATRICES TEST
    Desai, Mahesh
    BRITISH JOURNAL OF MEDICAL PSYCHOLOGY, 1952, 25 : 48 - 53
  • [25] TEST-RETEST RELIABILITY OF THE PARTICIPATION DOMAIN OF THE STROKE IMPACT SCALE IN PERSONS WITH CHRONIC STROKE
    Ekstrand, Elisabeth
    Lexell, Jan
    Brogardh, Christina
    JOURNAL OF REHABILITATION MEDICINE, 2018, 50 (09) : 843 - 846
  • [26] TEST-RETEST RELIABILITY OF THE DYNAVISION APPARATUS
    KLAVORA, P
    GASKOVSKI, P
    FORSYTH, R
    PERCEPTUAL AND MOTOR SKILLS, 1994, 79 (01) : 448 - 450
  • [27] TEST-RETEST RELIABILITY IN CLINICAL ELECTROCOCHLEOGRAPHY
    BERGHOLTZ, LM
    HOOPER, RE
    MEHTA, DC
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1976, 85 (05): : 679 - 685
  • [28] Test-retest and interobserver reliability of EUROTEST
    Frank-García, A
    Carnero-Pardo, C
    Guardado-Santervás, P
    Rubí-Callejón, J
    Gómez-Camello, A
    Goñi-Imizcoz, M
    Indatkoetxea-Juanbeltz, B
    Lacruz-Bescoz, F
    Sánchez-Cantalejo, E
    Lara-Lara, M
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2005, 238 : S284 - S285
  • [29] Test-retest reliability of cognitive EEG
    McEvoy, LK
    Smith, ME
    Gevins, A
    CLINICAL NEUROPHYSIOLOGY, 2000, 111 (03) : 457 - 463
  • [30] TEST-RETEST RELIABILITY IN POPULATION RESEARCH
    BRACKBILL, Y
    STUDIES IN FAMILY PLANNING, 1974, 5 (08) : 261 - 266