Precise Determination of the Lutetium Isotopic Composition in Rocks and Minerals Using Multicollector ICPMS

被引:14
|
作者
Wimpenny, Josh B. [1 ]
Amelin, Yuri [2 ]
Yin, Qing-Zhu [1 ]
机构
[1] Univ Calif Davis, Dept Earth & Planetary Sci, Davis, CA 95616 USA
[2] Australian Natl Univ, Res Sch Earth Sci, Canberra, ACT, Australia
关键词
LU-HF; DECAY; ND; SM; CONSTRAINTS; SYSTEMATICS; SM-147-ND-143; LU-176-HF-176; CHONDRITES; SEPARATION;
D O I
10.1021/ac401828w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Evidence of Hf-176 excess in select meteorites older than 4556Ma was suggested to be caused by excitation of long-lived natural radionuclide Lu-176 to its short-lived isomer Lu-176m, due to an irradiation event during accretion in the early solar system. A result of this process would be a deficit in Lu-176 in irradiated samples by between 1 parts per thousand and 7 parts per thousand. Previous measurements of the Lu isotope ratio in rock samples have not been of sufficient precision to resolve such a phenomenon. We present a new analytical technique designed to measure the Lu-176/Lu-175 isotope ratio in rock samples to a precision of similar to 0.1 parts per thousand using a multicollector inductively coupled mass spectrometer (MC-ICPMS). To account for mass bias we normalized all unknowns to Ames Lu. To correct for any drift and instability associated with mass bias, all standards and samples are doped with W metal and normalized to the nominal W isotopic composition. Any instability in the mass bias is then corrected by characterizing the relationship between the fractionation factor of Lu and W, which is calculated at the start of every analytical session. After correction for isobaric interferences, in particular Yb-176, we were able to measure Lu-176/Lu-175 ratios in samples to a precision of similar to 0.1 parts per thousand. However, these terrestrial standards were fractionated from Ames Lu by an average of 1.22 +/- 0.09 parts per thousand. This offset in Lu-176/Lu-175 is probably caused by isotopic fractionation of Lu during industrial processing of the Ames Lu standard. To allow more straightforward data comparison we propose the use of NIST3130a as a bracketing standard in future studies. Relative to NIST3130a, the terrestrial standards have a final weighted mean delta Lu-176 value of 0.11 +/- 0.09 parts per thousand. All samples have uncertainties of better than 0.11 parts per thousand; hence, our technique is fully capable of resolving any differences in delta Lu-176 of greater than 1 parts per thousand.
引用
收藏
页码:11258 / 11264
页数:7
相关论文
共 50 条
  • [41] An analytical method for precise determination of the cadmium isotopic composition in plant samples using multiple collector inductively coupled plasma mass spectrometry
    Wei, Rongfei
    Guo, Qingjun
    Wen, Hanjie
    Yang, Junxing
    Peters, Marc
    Zhu, Chuanwei
    Ma, Jie
    Zhu, Guangxu
    Zhang, Hanzhi
    Tian, Liyan
    Wang, Chunyu
    Wan, Yingxin
    ANALYTICAL METHODS, 2015, 7 (06) : 2479 - 2487
  • [42] SPECTROCHEMICAL DETERMINATION OF LITHIUM, SODIUM, POTASSIUM AND RUBIDIUM IN ROCKS AND MINERALS USING THE STALLWOOD JET
    SHAW, DM
    WICKREMASINGHE, OC
    WEBER, JN
    ANALYTICA CHIMICA ACTA, 1960, 22 (04) : 398 - 400
  • [43] Isotopic composition of Yb and the determination of Lu concentrations and Lu/Hf ratios by isotope dilution using MC-ICPMS -: art. no. Q11002
    Vervoort, JD
    Patchett, PJ
    Söderlund, U
    Baker, M
    GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2004, 5
  • [44] Precise and accurate measurement of 226Ra-230Th-238U disequilibria in volcanic rocks using plasma ionization multicollector mass spectrometry
    Pietruszka, AJ
    Carlson, RW
    Hauri, EH
    CHEMICAL GEOLOGY, 2002, 188 (3-4) : 171 - 191
  • [45] Determination of the isotopic composition of tungsten using MC-ICP-MS
    Zhang, Rouxi
    Meija, Juris
    Huang, Yi
    Pei, Xiangjun
    Mester, Zoltan
    Yang, Lu
    ANALYTICA CHIMICA ACTA, 2019, 1089 : 19 - 24
  • [46] A simple method for the precise determination of >=40 trace elements in geological samples by ICPMS using enriched isotope internal standardisation
    Eggins, SM
    Woodhead, JD
    Kinsley, LPJ
    Mortimer, GE
    Sylvester, P
    McCulloch, MT
    Hergt, JM
    Handler, MR
    CHEMICAL GEOLOGY, 1997, 134 (04) : 311 - 326
  • [47] Determination of the Tin Stable Isotopic Composition in Tin-bearing Metals and Minerals by MC-ICP-MS
    Bruegmann, Gerhard
    Berger, Daniel
    Pernicka, Ernst
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2017, 41 (03) : 437 - 448
  • [48] Application of an Isotope Binary Mixing Model for Determination of Precise Mercury Isotopic Composition in Samples with Low Mercury Concentration
    Huang, Shuyuan
    Song, Qingyong
    Zhang, Yuanbiao
    Yuan, Dongxing
    Sun, Lumin
    Chen, Yaojin
    Jiang, Ronggen
    Lin, Hui
    ANALYTICAL CHEMISTRY, 2019, 91 (11) : 7063 - 7069
  • [49] Effects of different cone combinations on accurate and precise determination of Li isotopic composition by MC-ICP-MS
    Gou, Long-Fei
    Jin, Zhang-Dong
    Deng, Li
    He, Mao-Yong
    Liu, Chun-Yao
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 146 : 1 - 8
  • [50] SPECTROPHOTOMETRIC DETERMINATION OF FLUORINE IN SILICATE ROCKS AND MINERALS USING ZIRCONIUM-CYANINE R SYSTEM
    KHAN, SA
    STONE, M
    REVUE ROUMAINE DE CHIMIE, 1982, 27 (07) : 885 - 893