Precise Determination of the Lutetium Isotopic Composition in Rocks and Minerals Using Multicollector ICPMS

被引:14
|
作者
Wimpenny, Josh B. [1 ]
Amelin, Yuri [2 ]
Yin, Qing-Zhu [1 ]
机构
[1] Univ Calif Davis, Dept Earth & Planetary Sci, Davis, CA 95616 USA
[2] Australian Natl Univ, Res Sch Earth Sci, Canberra, ACT, Australia
关键词
LU-HF; DECAY; ND; SM; CONSTRAINTS; SYSTEMATICS; SM-147-ND-143; LU-176-HF-176; CHONDRITES; SEPARATION;
D O I
10.1021/ac401828w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Evidence of Hf-176 excess in select meteorites older than 4556Ma was suggested to be caused by excitation of long-lived natural radionuclide Lu-176 to its short-lived isomer Lu-176m, due to an irradiation event during accretion in the early solar system. A result of this process would be a deficit in Lu-176 in irradiated samples by between 1 parts per thousand and 7 parts per thousand. Previous measurements of the Lu isotope ratio in rock samples have not been of sufficient precision to resolve such a phenomenon. We present a new analytical technique designed to measure the Lu-176/Lu-175 isotope ratio in rock samples to a precision of similar to 0.1 parts per thousand using a multicollector inductively coupled mass spectrometer (MC-ICPMS). To account for mass bias we normalized all unknowns to Ames Lu. To correct for any drift and instability associated with mass bias, all standards and samples are doped with W metal and normalized to the nominal W isotopic composition. Any instability in the mass bias is then corrected by characterizing the relationship between the fractionation factor of Lu and W, which is calculated at the start of every analytical session. After correction for isobaric interferences, in particular Yb-176, we were able to measure Lu-176/Lu-175 ratios in samples to a precision of similar to 0.1 parts per thousand. However, these terrestrial standards were fractionated from Ames Lu by an average of 1.22 +/- 0.09 parts per thousand. This offset in Lu-176/Lu-175 is probably caused by isotopic fractionation of Lu during industrial processing of the Ames Lu standard. To allow more straightforward data comparison we propose the use of NIST3130a as a bracketing standard in future studies. Relative to NIST3130a, the terrestrial standards have a final weighted mean delta Lu-176 value of 0.11 +/- 0.09 parts per thousand. All samples have uncertainties of better than 0.11 parts per thousand; hence, our technique is fully capable of resolving any differences in delta Lu-176 of greater than 1 parts per thousand.
引用
收藏
页码:11258 / 11264
页数:7
相关论文
共 50 条
  • [21] Determination of precise nickel isotopic composition and natural nickel isotopic variation by ICP-MS
    Tanimizu, Masaharu
    Hirata, Takafumi
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A636 - A636
  • [22] ISOTOPIC COMPOSITION OF HYDROGEN FROM MINERALS AND ROCKS OF THE TSAGAN-SUBURGA DEPOSIT (SOUTH MONGOLIA)
    BERZINA, AP
    KURODA, I
    SOTNIKOV, VI
    DOKLADY AKADEMII NAUK SSSR, 1985, 280 (01): : 220 - 223
  • [23] THE ISOTOPIC COMPOSITION OF CARBON AND OXYGEN IN CALCAREOUS ROCKS AND MINERALS OF THE DEVONIAN DEPOSITS WITHIN THE PRIPYAT DEPRESSION
    ZAGNITKO, VN
    LUGOVAYA, IP
    MIKHAILOV, ND
    DOKLADY AKADEMII NAUK BELARUSI, 1989, 33 (02): : 163 - 166
  • [24] Accurate Determination of Silver Isotopic Composition in Silicate Rocks with Low Silver Abundance
    Zhu, Yuan-Feng
    Wei, Hai-Zhen
    Wang, Jun-Lin
    Williams-Jones, Anthony E.
    Wang, Zai-Cong
    Jiang, Shao-Yong
    Hohl, Simon V.
    Huan, Chun
    Zhang, Miao-Miao
    ACS EARTH AND SPACE CHEMISTRY, 2023, 7 (10): : 2031 - 2041
  • [25] PRECISE DETERMINATION OF URANIUM IN ROCKS AND MINERALS BY NEUTRON-ACTIVATION ANALYSIS USING I-133 FISSION-PRODUCT
    DELFIORE, G
    PETERS, JM
    ROELANDT.I
    CHEMICAL GEOLOGY, 1974, 13 (04) : 309 - 319
  • [26] Comparison of Mass Discrimination Correction Methods and Sample Introduction Systems for the Determination of Lead Isotopic Composition Using a Multicollector Inductively Coupled Plasma Mass Spectrometer
    Gallon, Celine
    Aggarwal, Jugdeep
    Flegal, A. Russell
    ANALYTICAL CHEMISTRY, 2008, 80 (22) : 8355 - 8363
  • [27] New sample preparation techniques for the determination of Si isotopic compositions using MC-ICPMS
    Georg, R. B.
    Reynolds, B. C.
    Frank, M.
    Halliday, A. N.
    CHEMICAL GEOLOGY, 2006, 235 (1-2) : 95 - 104
  • [28] Determination of Li and B isotopic composition in the microvolumes of meteorites by a highly sensitive, precise method
    Kaviladze, M. S.
    Gubadze, N. V.
    International Journal of Mass Spectrometry and Ion Processes, 161 (1/3):
  • [29] Determination of Li and B isotopic composition in the microvolumes of meteorites by a highly sensitive, precise method
    Kaviladze, MS
    Gubadze, NV
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 161 (1-3) : 87 - 89
  • [30] DETERMINATION OF LITHIUM IN SILICATE ROCKS AND MINERALS USING A SIMPLE FLAME PHOTOMETER
    KHAN, SA
    STONE, M
    REVUE ROUMAINE DE CHIMIE, 1974, 19 (10) : 1669 - 1676