Synthesis, characterization and analytical application of Zn(II)-imprinted polymer as an efficient solid-phase extraction technique for trace determination of zinc ions in food samples

被引:66
|
作者
Behbahani, Mohammad [1 ]
Salarian, Mani [2 ]
Bagheri, Akbar [1 ]
Tabani, Hadi [1 ]
Omidi, Fariborz [3 ]
Fakhari, Alireza [1 ]
机构
[1] Shahid Beheshti Univ, Dept Chem, GC, Tehran 1983963113, Iran
[2] Georgia State Univ, Dept Chem, Atlanta, GA 30303 USA
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth, Tehran, Iran
关键词
Ion imprinted polymer; Copolymerization; Zinc; Solid-phase extraction; Preconcentration; Food analysis; Food Composition; Flame atomic absorption spectrometry; Food safety; Metal contamination levels in food; FLOW-INJECTION PRECONCENTRATION; EXPERIMENTAL-DESIGN; IMPRINTED POLYMER; WATER SAMPLES; METAL-IONS; COPPER; OPTIMIZATION; SORBENT; CU(II); FISH;
D O I
10.1016/j.jfca.2013.10.003
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Zinc imprinted polymer (Zn(II)-IIP) as a solid-phase extraction technique was applied for preconcentration and determination of zinc in environmental and food samples by FAAS. Zn(II)-IIP was synthesized by copolymerization of 2-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, 2,2-azobisisobutyronitrile as the initiator, Zn(NO3)(2) as the template ion, diphenylcarbazone as the ligand, and methanol/dichloromethane (50:50) as the solvent. The synthesized polymer particles were characterized by thermogravimetry analysis (TGA), differential thermal analysis (DTA), scanning electron microscopy (SEM), Fourier transform infrared spectrometry (FT-IR), and X-ray diffraction (XRD). The optimization process was carried out using the central composite design (CCD). With this design, the optimum conditions for the adsorption step were 6.6, 30 mg, and 23 min, for pH, mass of polymer and adsorption time respectively, and for desorption step the optimal conditions were 14 mL, 12% (v/v), and 23 min, for volume of eluent, concentration of eluent, and desorption time, respectively. Under the optimized conditions, the detection limit of the proposed method was found to be 0.15 mu g L-1, while the relative standard deviation (RSD) for 10 replicate measurements was calculated to be 2.8%. Therefore the introduced selective solid phase extraction method can be used as a reliable technique for selective and sensitive trace detection of zinc in different food matrixes, and the reliability of the proposed solid phase extraction technique was established by the analysis of standard reference materials. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 50 条
  • [41] Development of a Selective Molecularly Imprinted Polymer-Based Solid-Phase Extraction for Copper from Food Samples
    Khajeh, Mostafa
    Sanchooli, Esmael
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2010, 135 (1-3) : 325 - 333
  • [42] Development of a Selective Molecularly Imprinted Polymer-Based Solid-Phase Extraction for Copper from Food Samples
    Mostafa Khajeh
    Esmael Sanchooli
    Biological Trace Element Research, 2010, 135 : 325 - 333
  • [43] Synthesis and Characterization of Nanopore MoVI-Imprinted Polymer and Its Application as Solid Phase for Extraction, Separation and Preconcentration of Molybdenum Ions from Water Samples
    Ardestani, Fatemeh
    Hosseini, Majid Haji
    Taghizadeh, Majid
    Pourjavid, Mohammad Reza
    Rezaee, Mohammad
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (07) : 1279 - 1289
  • [44] Solid-phase extraction based on polyethyleneimine-modified eggshell membrane coupled with FAAS for the selective determination of trace copper(II) ions in environmental and food samples
    Zou, Xue
    Huang, Yuming
    ANALYTICAL METHODS, 2013, 5 (22) : 6486 - 6493
  • [45] Selective trace analysis of diclofenac in surface and wastewater samples using solid-phase extraction with a new molecularly imprinted polymer
    Sun, Z.
    Schuessler, W.
    Sengl, M.
    Niessner, R.
    Knopp, D.
    ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) : 73 - 81
  • [46] Multivariate optimization of molecularly imprinted polymer solid-phase extraction applied to parathion determination in different water samples
    Alizadeh, Taher
    Ganjali, Mohammad Reza
    Nourozi, Parviz
    Zare, Mashaalah
    ANALYTICA CHIMICA ACTA, 2009, 638 (02) : 154 - 161
  • [47] Online coupling of molecularly imprinted solid-phase extraction to HPLC for determination of trace tetracycline antibiotic residues in egg samples
    Jing, Tao
    Niu, Jiwei
    Xia, Huan
    Dai, Qing
    Zheng, Hongyan
    Hao, Qiaolin
    Mei, Surong
    Zhou, Yikai
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (12) : 1469 - 1476
  • [48] Synthesis, characterization, and application of novel Zn(II)-ionic imprinted polymer for preconcentration of Zn(II) ions from aqueous solution
    Wirawan, T.
    Supriyanto, G.
    Soegianto, A.
    12TH JOINT CONFERENCE ON CHEMISTRY, 2018, 349
  • [49] Determination of trace bisphenol A in complex samples using selective molecularly imprinted solid-phase extraction coupled with capillary electrophoresis
    Mei, Surong
    Wu, Da
    Jiang, Ming
    Lu, Bin
    Lim, Jae-Min
    Zhou, Yi-Kai
    Lee, Yong-Ill
    MICROCHEMICAL JOURNAL, 2011, 98 (01) : 150 - 155
  • [50] Selective solid-phase extraction of trace Pb(II) from aqueous solution using Pb(II)-ion imprinted polymer
    Shirazifard, Peyman
    Sadjadi, Sodeh
    Ahmadi, Seyed Javad
    Faghihi, Farshad
    SEPARATION SCIENCE AND TECHNOLOGY, 2016, 51 (02) : 248 - 254