Synthesis, characterization and analytical application of Zn(II)-imprinted polymer as an efficient solid-phase extraction technique for trace determination of zinc ions in food samples

被引:66
|
作者
Behbahani, Mohammad [1 ]
Salarian, Mani [2 ]
Bagheri, Akbar [1 ]
Tabani, Hadi [1 ]
Omidi, Fariborz [3 ]
Fakhari, Alireza [1 ]
机构
[1] Shahid Beheshti Univ, Dept Chem, GC, Tehran 1983963113, Iran
[2] Georgia State Univ, Dept Chem, Atlanta, GA 30303 USA
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth, Tehran, Iran
关键词
Ion imprinted polymer; Copolymerization; Zinc; Solid-phase extraction; Preconcentration; Food analysis; Food Composition; Flame atomic absorption spectrometry; Food safety; Metal contamination levels in food; FLOW-INJECTION PRECONCENTRATION; EXPERIMENTAL-DESIGN; IMPRINTED POLYMER; WATER SAMPLES; METAL-IONS; COPPER; OPTIMIZATION; SORBENT; CU(II); FISH;
D O I
10.1016/j.jfca.2013.10.003
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Zinc imprinted polymer (Zn(II)-IIP) as a solid-phase extraction technique was applied for preconcentration and determination of zinc in environmental and food samples by FAAS. Zn(II)-IIP was synthesized by copolymerization of 2-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, 2,2-azobisisobutyronitrile as the initiator, Zn(NO3)(2) as the template ion, diphenylcarbazone as the ligand, and methanol/dichloromethane (50:50) as the solvent. The synthesized polymer particles were characterized by thermogravimetry analysis (TGA), differential thermal analysis (DTA), scanning electron microscopy (SEM), Fourier transform infrared spectrometry (FT-IR), and X-ray diffraction (XRD). The optimization process was carried out using the central composite design (CCD). With this design, the optimum conditions for the adsorption step were 6.6, 30 mg, and 23 min, for pH, mass of polymer and adsorption time respectively, and for desorption step the optimal conditions were 14 mL, 12% (v/v), and 23 min, for volume of eluent, concentration of eluent, and desorption time, respectively. Under the optimized conditions, the detection limit of the proposed method was found to be 0.15 mu g L-1, while the relative standard deviation (RSD) for 10 replicate measurements was calculated to be 2.8%. Therefore the introduced selective solid phase extraction method can be used as a reliable technique for selective and sensitive trace detection of zinc in different food matrixes, and the reliability of the proposed solid phase extraction technique was established by the analysis of standard reference materials. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 50 条
  • [21] Synthesis and application of ion-imprinted polymer particles for solid-phase extraction and determination of trace scandium by ICP-MS in different matrices
    Liu, Jin
    Yang, Xiaoli
    Cheng, Xianzhong
    Peng, Yuan
    Chen, Hongmei
    ANALYTICAL METHODS, 2013, 5 (07) : 1811 - 1817
  • [22] Synthesis of Molecularly Imprinted Polymer for Selective Solid-Phase Extraction of Salbutamol from Urine Samples
    Mohammadi, Ali
    Alizadeh, Taher
    Dinarvand, Rassoul
    Ganjali, Mohammad Reza
    Walker, Roderick B.
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (04) : 2875 - 2880
  • [23] Synthesis and application of a molecularly imprinted polymer in the solid-phase extraction of ketoprofen from wastewater
    Zunngu, Silindile Senamile
    Madikizela, Lawrence Mzukisi
    Chimuka, Luke
    Mdluli, Phumlane Selby
    COMPTES RENDUS CHIMIE, 2017, 20 (05) : 585 - 591
  • [24] Synthesis, characterization and application of a novel ion-imprinted polymer based voltammetric sensor for selective extraction and trace determination of cobalt (II) ions
    Torkashvand, M.
    Gholivand, M. B.
    Azizi, R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 283 - 291
  • [25] Selective solid-phase extraction using molecularly imprinted polymer as a sorbent for the analysis of fenarimol in food samples
    Khan, Shagufta
    Bhatia, Tejasvi
    Trivedi, Purushottam
    Satyanarayana, G. N. V.
    Mandrah, Kapil
    Saxena, Prem Narayan
    Mudiam, Mohana Krishna Reddy
    Roy, Somendu Kumar
    FOOD CHEMISTRY, 2016, 199 : 870 - 875
  • [26] Selective solid-phase extraction using molecular imprinted polymer sorbent for the analysis of Florfenicol in food samples
    Sadeghi, Susan
    Jahani, Moslem
    FOOD CHEMISTRY, 2013, 141 (02) : 1242 - 1251
  • [27] Synthesis and application of surface-imprinted activated carbon sorbent for solid-phase extraction and determination of copper (II)
    Li, Zhenhua
    Li, Jingwen
    Wang, Yanbin
    Wei, Yajun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 117 : 422 - 427
  • [28] Surface imprinted-covalent organic frameworks for efficient solid-phase extraction of fluoroquinolones in food samples
    Su, Li-Hong
    Qian, Hai -Long
    Yang, Cheng
    Wang, Chuanxi
    Wang, Zhenyu
    Yan, Xiu- Ping
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 459
  • [29] Selective Determination of Chloramphenicol in Milk Samples by the Solid-Phase Extraction Based on Dummy Molecularly Imprinted Polymer
    Zhao, Fengnian
    She, Yongxin
    Zhang, Chao
    Wang, Shanshan
    Du, Xinwei
    Jin, Fen
    Jin, Maojun
    Shao, Hua
    Zheng, Lufei
    Wang, Jing
    FOOD ANALYTICAL METHODS, 2017, 10 (07) : 2566 - 2575
  • [30] Selective Determination of Chloramphenicol in Milk Samples by the Solid-Phase Extraction Based on Dummy Molecularly Imprinted Polymer
    Fengnian Zhao
    Yongxin She
    Chao Zhang
    Shanshan Wang
    Xinwei Du
    Fen Jin
    Maojun Jin
    Hua Shao
    Lufei Zheng
    Jing Wang
    Food Analytical Methods, 2017, 10 : 2566 - 2575