摘要
The first example of a biotin-streptavidin signal amplification strategy was developed for a highly sensitive chemiluminescent immunoassay for chicken interferon-gamma at sub-picogram per millilitre level. This approach displays a 415-fold increase in the detection limit in comparison with conventional methods.
引用
收藏
页码:22868 / 22871
页数:4
相关论文
共 50 条
  • [1] Development of a sensitive, rapid, biotin-streptavidin based chemiluminescent enzyme immunoassay for human thyroid stimulating hormone
    Lin, Zhen
    Wang, Xu
    Li, Zhen-Jia
    Ren, Shi-Qi
    Chen, Guo-Nan
    Ying, Xi-Tang
    Lin, Jin-Ming
    TALANTA, 2008, 75 (04) : 965 - 972
  • [2] High efficient chemiluminescent immunoassays for the detection of diclazuril in chicken muscle based on biotin-streptavidin system
    Li, Yuan
    Wang, Yahui
    Li, PeiPei
    Zhang, Yingjie
    Ke, Yuebin
    Yu, Wenbo
    Wen, Kai
    Ding, Shuangyang
    Wang, Zhanhui
    Yu, Xuezhi
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2020, 31 (01) : 255 - 267
  • [3] Highly sensitive rapid chemiluminescent immunoassay using the DNAzyme label for signal amplification
    Wang, Chen
    Wu, Jie
    Zong, Chen
    Ju, Huangxian
    Yan, Feng
    ANALYST, 2011, 136 (20) : 4295 - 4300
  • [4] Ultrasensitive simultaneous detection of four biomarkers based on hybridization chain reaction and biotin-streptavidin signal amplification strategy
    Zhu, Qiang
    Chai, Yaqin
    Zhuo, Ying
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 42 - 48
  • [5] A sensitive immunoassay based on direct hapten coated format and biotin-streptavidin system for the detection of chloramphenicol
    Sai, Na
    Chen, Yiping
    Liu, Nan
    Yu, Guanggui
    Su, Pu
    Feng, Yi
    Zhou, Zhijiang
    Liu, Xiaoyu
    Zhou, Huanying
    Gao, Zhixian
    Ning, Bao An
    TALANTA, 2010, 82 (04) : 1113 - 1121
  • [6] A competitive enzyme immunoassay for follicle-stimulating hormone in ovine plasma using biotin-streptavidin amplification
    Watanabe, H
    Miyamoto, A
    Fukui, Y
    REPRODUCTION FERTILITY AND DEVELOPMENT, 1997, 9 (06) : 597 - 601
  • [7] Highly Sensitive, Stable InP Quantum Dot Fluorescent Probes for Quantitative Immunoassay Through Nanostructure Tailoring and Biotin-Streptavidin Coupling
    Zhang, Lifang
    Xu, Han
    Zhang, Xuhui
    Chen, Xinxin
    Lv, Yanbing
    Zhang, Ruixue
    Wang, Lei
    Wu, Ruili
    Shen, Huaibin
    Li, Lin Song
    INORGANIC CHEMISTRY, 2024, 63 (10) : 4604 - 4613
  • [8] A paramagnetic microspheres based automation-friendly rapid chemiluminescent immunoassay method for sensitive detection of chicken interferon-γ
    Dai, Hua
    Zhu, Jing
    Yang, Zhanjun
    Li, Juan
    Jiao, Xin'an
    Hu, Xiaoya
    Wang, Joseph
    CHEMICAL COMMUNICATIONS, 2013, 49 (17) : 1708 - 1710
  • [9] IMMUNOAFFINITY CHROMATOGRAPHY AND A BIOTIN-STREPTAVIDIN AMPLIFIED ENZYME-IMMUNOASSAY FOR SENSITIVE AND SPECIFIC ESTIMATION OF ESTRADIOL-17-BETA
    MEYER, HHD
    SAUERWEIN, H
    MUTAYOBA, BM
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1990, 35 (02): : 263 - 269
  • [10] Optical fiber immunosensor based on graphene oxide and biotin-streptavidin(SA) signal amplification system for rapid and sensitive detection of 17ß-estradiol(E2)
    Guo, Wanmei
    Guo, Qi
    Yu, Hongwen
    Yu, Yongsen
    Jin, Guangyong
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS XII, 2022, 12321