Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS

被引:84
|
作者
Balcaen, Lieve [1 ]
Bolea-Fernandez, Eduardo [1 ]
Resano, Martin [2 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[2] Univ Zaragoza, Dept Analyt Chem, E-50009 Zaragoza, Spain
关键词
Blood serum; Titanium; Reaction cell inductively coupled plasma mass spectrometry; Implants; TOTAL HIP-ARTHROPLASTY; TITANIUM LEVELS; METAL RELEASE; MS; SPECTROMETRY; EXCRETION; IMPLANTS; VANADIUM; URINE; ALLOY;
D O I
10.1016/j.aca.2013.10.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O-2 and NH3/He have been compared as reaction gases. While the use of O-2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti+ ions into Ti(NH3)(6)(+) cluster ions by using NH3/He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L-1 (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF-ICP-MS. As a proof-of-concept, the newly developed method was successfully applied to the determination of Ti in serum samples obtained from individuals with and without Ti-based implants. All results were found to be in good agreement with those obtained by means of SF-ICP-MS. The typical basal Ti level in human serum was found to be < 1 mu g L-1, while values in the range of 2-6 mu g L-1 were observed for implanted patients. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Trace element determination in vitamin E using ICP-MS
    Claudia A. Ponce de León
    Maria Montes Bayón
    Joseph A. Caruso
    Analytical and Bioanalytical Chemistry, 2002, 374 : 230 - 234
  • [32] Trace element determination in vitamin E using ICP-MS
    de León, CAP
    Bayón, MM
    Caruso, JA
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (02) : 230 - 234
  • [33] Accurate determination of arsenic and selenium in plant food samples by using ICP-MS/MS
    Hu, Xianqiao
    Cao, Zhaoyun
    Sun, Weihua
    Yang, Huan
    Xu, Ping
    Zhu, Zhiwei
    ANALYTICAL METHODS, 2016, 8 (32) : 6150 - 6157
  • [34] Accurate determination of S in organic matrices using isotope dilution ICP-MS/MS
    Balcaen, Lieve
    Woods, Glenn
    Resano, Martin
    Vanhaecke, Frank
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (01) : 33 - 39
  • [35] Determination of 20 Trace Elements in the Blood Collection Tubes with ICP-MS
    Xiong Chan
    Jiang, Xue-hui
    Tian Ya-ping
    Ma Qing-wei
    Liu Li-peng
    Guo Guang-hong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (11) : 3676 - 3682
  • [36] Determination of Ultra-trace Tellurium in Steel by ID-ICP-MS/ MS with Liquid-Liquid Extraction
    Junichi Hirata
    Daisuke Itabashi
    Michihiro Aimoto
    Analytical Sciences, 2021, 37 : 1757 - 1763
  • [37] Ultra-trace Measurements of 210Pb in natural occurring radioactive materials by ICP-MS
    Amr, M. A.
    Al-Saad, K. A.
    Helal, A. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (02): : 237 - 241
  • [38] Determination of Ultra-trace Tellurium in Steel by ID-ICP-MS/ MS with Liquid-Liquid Extraction
    Hirata, Junichi
    Itabashi, Daisuke
    Aimoto, Michihiro
    ANALYTICAL SCIENCES, 2021, 37 (12) : 1757 - 1763
  • [39] Feasibility of ultra-trace determination of bromine and iodine in honey by ICP-MS using high sample mass in microwave-induced combustion
    Vanize C. Costa
    Rochele S. Picoloto
    Carla A. Hartwig
    Paola A. Mello
    Erico M. M. Flores
    Marcia F. Mesko
    Analytical and Bioanalytical Chemistry, 2015, 407 : 7957 - 7964