Sensitive electrochemical determination of α-fetoprotein using a glassy carbon electrode modified with in-situ grown gold nanoparticles, graphene oxide and MWCNTs acting as signal amplifiers

被引:10
|
作者
Gao, Yan-Sha [1 ,2 ]
Zhu, Xiao-Fei [1 ]
Yang, Tao-Tao [1 ]
Xu, Jing-Kun [1 ]
Lu, Li-Min [2 ]
Zhang, Kai-Xin [1 ]
机构
[1] Jiangxi Sci & Technol Normal Univ, Jiangxi Key Lab Organ Chem, Nanchang 330013, Peoples R China
[2] Jiangxi Agr Univ, Coll Sci, Nanchang 330045, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical immunosensor; alpha-fetoprotein; Gold nanoparticles; Graphene oxide; Multi-walled carbon nanotubes; AMPEROMETRIC IMMUNOSENSOR; ELECTROCATALYTIC PERFORMANCE; ONE-STEP; AU; NANOTUBES; POLY(5-FORMYLINDOLE); IMMOBILIZATION; NANOCOMPOSITES; NANOHYBRID; MARKERS;
D O I
10.1007/s00604-015-1537-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe an electrochemical immunoassay for alpha-fetoprotein (alpha-FP) using a glassy carbon electrode (GCE) modified with a nanocomposite made from gold nanoparticles, graphene oxide and multi-walled carbon nanotubes (AuNPs/GO-MWCNTs) and acting as a signal amplification matrix. The nanocomposite was synthesized in a one-pot redox reaction between GO and HAuCl4 without using an additional reductant. The stepwise assembly of the immunoelectrode was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. The interaction of antigen and antibody on the surface of the electrode creates a barrier for electrons and causes retarded electron transfer, this resulting in decreased signals in differential pulse voltammetry of hexacyanoferrate which is added as an electrochemical probe. Using this strategy and by working at a potential of 0.2 V (vs. SCE), a wide analytical range (0.01 - 100 nga (TM) mLaEuro3/4(1)) is covered. The correlation coefficient is 0.9929, and the limit of detection is as low as 3 pga (TM) mLaEuro3/4(1) at a signal-to-noise ratio of 3. This electrochemical immunoassay combines the specificity of an immunological detection scheme with the sensitivity of an electrode modified with AuNPs and GO-MWCNTs.
引用
收藏
页码:2027 / 2035
页数:9
相关论文
共 50 条
  • [21] Electrochemical Determination of Acetaminophen Using Gold Nanoparticles-Multiwall Carbon Nanotubes Modified Glassy Carbon Electrode
    Peng, Youyuan
    Zheng, Zhifu
    AMERICAN LABORATORY, 2014, 46 (09) : 16 - 19
  • [22] Electrochemical Detection of Paracetamol Using Graphene Oxide -Modified Glassy Carbon Electrode
    Zidan, Mohammed
    Zawawi, Ruzniza Mohd
    Erhayem, Mohamed
    Salhin, Abdussalam
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7605 - 7613
  • [23] Electrochemical Determination of Diclofenac Sodium in Pharmaceutical Sample Using Copper Nanoparticles/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Yu, Haichi
    Jiao, Jianhang
    Li, Qiuju
    Li, Yingzhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (10): : 1 - 12
  • [24] Electrochemical determination of isoprenaline using a graphene-modified glassy carbon electrode
    Meifeng Chen
    Xinying Ma
    Xia Li
    Journal of Solid State Electrochemistry, 2012, 16 : 3261 - 3266
  • [25] Electrochemical determination of isoprenaline using a graphene-modified glassy carbon electrode
    Chen, Meifeng
    Ma, Xinying
    Li, Xia
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (10) : 3261 - 3266
  • [26] Sensitive Electrochemical Determination of Oxcarbazepine using MWCNT Modified Glassy Carbon Electrode
    Ershad, Sohrab
    Sani, Mahnaz Akbari
    Hosseinzadeh, Mehdi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (08): : 637 - 649
  • [27] Ultrasensitive Determination of Dopamine and Uric Acid Based on Gold Nanoparticles@Carbon Dots/Electrochemical Reduced Graphene Oxide modified glassy carbon electrode
    Li, Muyi
    Yang, Xiang
    Liu, Wenjun
    Wang, Huixian
    Jiang, Hongmei
    Liu, Xiaoying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (08): : 1 - 17
  • [28] Electrochemical Determination of Bisphenol A on a Glassy Carbon Electrode Modified with Gold Nanoparticles Loaded on Reduced Graphene Oxide-Multi-Walled Carbon Nanotubes Composite
    Yu Hao
    Feng Xiao
    Chen Xiao-Xia
    Qiao Jin-Li
    Gao Xiao-Ling
    Xu Na
    Gao Lou-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (05) : 713 - 720
  • [29] A Glassy Carbon Electrode Modified with Electrochemically Reduced Graphene Oxide/Gold Nanoparticles-Chitosan Composite Film for Sensitive Determination of Uric Acid
    Wu Ling
    Cao Zhong
    Song Tian-Ming
    Song, Cheng
    Xie Jing-Lei
    He Jing-Lin
    Xiao Zhong-Liang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (11) : 1656 - 1660
  • [30] A sensitive DNA biosensor fabricated from gold nanoparticles and graphene oxide on a glassy carbon electrode
    Hajihosseini, Saeedeh
    Nasirizadeh, Navid
    Hejazi, Mohammad Saeid
    Yaghmaei, Parichereh
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 61 : 506 - 515