Confocal dual-frequency enhances the damaging effect of high-intensity focused ultrasound in tissue-mimicking phantom

被引:5
|
作者
Kuang, Sheng-Li [1 ]
Hu, Bing [1 ]
Jiang, Li-Xin [1 ]
He, Pei-Zhong [2 ]
Xia, Rong-Min [3 ]
Shou, Wen-De [3 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Ultrasound Med, Peoples Hosp 6, Shanghai 200233, Peoples R China
[2] Xuzhou Normal Univ, Dept Phys, Xuzhou, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Biomed Engn, Shanghai 200233, Peoples R China
基金
中国国家自然科学基金;
关键词
HIFU; ultrasound; tissue-mimicking phantom; dual-frequency; lesion;
D O I
10.1080/13645700802274281
中图分类号
R61 [外科手术学];
学科分类号
摘要
The volume of the lesions created by conventional single-frequency high-intensity focused ultrasound (HIFU) is small, which leads to long treatment duration in patients who are undergoing tumor ablation. In this study, the lesions induced by confocal dual-frequency HIFU in an optically transparent tissue-mimic king phantom were investigated and compared with the lesions created by conventional single-frequency HIFU. The results show that using different exposure times resulted in lesions of different sizes in both dual-frequency and single-frequency HIFU modes at the same spatially averaged intensity level (ISAL=4900 W cm(2)), but the lesion dimensions made in dual-frequency mode were significantly larger than those made in single-frequency mode. Difference frequency acoustic fields that exist in the confocal region of dual-frequency HIFU may be the reason for the enlargement of the lesions' dimensions. The dual-frequency HIFU mode may represent a new technique to improve the ablation efficiency of HIFU. The total time for the ablation of a tumor can be reduced, thus requiring less therapy time and reducing possible patient complications.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 50 条
  • [21] Simulation and Measurement of Thermal Ablation in a Tissue-Mimicking Phantom and Ex-Vivo Porcine Liver by Using High Intensity Focused Ultrasound
    Kang Il Lee
    Journal of the Korean Physical Society, 2018, 73 : 1289 - 1294
  • [22] Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance-Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
    Holman, Ryan
    Guillemin, Pauline C.
    Lorton, Orane
    Desgranges, Stephane
    Contino-Pepin, Christiane
    Salomir, Rares
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (07): : 1510 - 1517
  • [23] Simulation and Measurement of Thermal Ablation in a Tissue-Mimicking Phantom and Ex-Vivo Porcine Liver by Using High Intensity Focused Ultrasound
    Lee, Kang Il
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (09) : 1289 - 1294
  • [24] NONLINEAR EFFECT IN FAT TISSUE FOR HIGH-INTENSITY FOCUSED ULTRASOUND
    Wang, Shou-bei
    Li, Ke
    Zhou, Bo-fan
    Ji, Xiang
    PROCEEDINGS OF 2016 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2016, : 127 - 130
  • [25] Rapid skin permeabilization by the simultaneous application of dual-frequency, high-intensity ultrasound
    Schoellhammer, Carl M.
    Polat, Baris E.
    Mendenhall, Jonathan
    Maa, Ruby
    Jones, Brianna
    Hart, Douglas P.
    Langer, Robert
    Blankschtein, Daniel
    JOURNAL OF CONTROLLED RELEASE, 2012, 163 (02) : 154 - 160
  • [26] Simultaneous Measurement of Thermophysical Properties of Tissue-Mimicking Phantoms for High Intensity Focused Ultrasound (HIFU) Exposures
    Jing Gao
    Jiang You
    Zhihong Huang
    Sandy Cochran
    George Corner
    International Journal of Thermophysics, 2012, 33 : 495 - 504
  • [27] Gel phantom for use in high-intensity focused ultrasound dosimetry
    Lafon, C
    Zderic, V
    Noble, ML
    Yuen, JC
    Kaczkowski, PJ
    Sapozhnikov, OA
    Chavrier, F
    Crum, LA
    Vaezy, S
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (10): : 1383 - 1389
  • [28] Focused ultrasound temperature effect in tissue-mimicking material and sheep liver
    Karaboce, Baki
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 131 - 134
  • [29] Simultaneous Measurement of Thermophysical Properties of Tissue-Mimicking Phantoms for High Intensity Focused Ultrasound (HIFU) Exposures
    Gao, Jing
    You, Jiang
    Huang, Zhihong
    Cochran, Sandy
    Corner, George
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2012, 33 (03) : 495 - 504
  • [30] Development and characterization of an innovative synthetic tissue-mimicking material for High Intensity Focused Ultrasound (HIFU) exposures
    Lafon, C
    Kaczkowski, PJ
    Vaezy, S
    Noble, M
    Sapozhnikov, OA
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1295 - 1298