Tuning the Performance of Organic Spintronic Devices Using X-Ray Generated Traps

被引:63
|
作者
Rybicki, J. [1 ]
Lin, R. [1 ]
Wang, F. [1 ]
Wohlgenannt, M. [1 ]
He, C. [2 ]
Sanders, T. [2 ]
Suzuki, Y. [2 ,3 ,4 ]
机构
[1] Univ Iowa, Dept Phys & Astron, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
[2] Univ Calif Berkeley, Dept Mat Sci & Engn, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
[4] Stanford Univ, Dept Appl Phys, Geballe Lab Adv Mat, Stanford, CA 94305 USA
关键词
ROOM-TEMPERATURE; LARGE MAGNETORESISTANCE; INJECTION; MECHANISM;
D O I
10.1103/PhysRevLett.109.076603
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
X rays produced during electron-beam deposition of metallic electrodes drastically change the performance of organic spintronic devices. The x rays generate traps with an activation energy of approximate to 0.5 eV in a commonly used organic. These traps lead to a dramatic decrease in spin-diffusion length in organic spin valves. In organic magnetoresistive (OMAR) devices, however, the traps strongly enhance magnetoresistance. OMAR is an intrinsic magnetotransport phenomenon and does not rely on spin injection. We discuss our observations in the framework of currently existing theories.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Radiopaque marking of devices for X-ray imaging
    Dickenson, Roger
    Medical Device Materials II: Proceedings from the Materials & Processes for Medical Devices Conference 2004, 2005, : 251 - 256
  • [42] Portable X-Ray Diagnostic Devices for Dentistry
    Potrakhov N.N.
    Potrakhov Y.N.
    Biomedical Engineering, 2017, 50 (6) : 406 - 409
  • [43] TRAPS CREATED IN POLYETHYLENE BY X-RAY AND NEUTRON-IRRADIATION
    OKKALIDES, D
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1984, 17 (03) : 563 - 569
  • [44] X-RAY LITHOGRAPHY FOR BUBBLE-DEVICES
    SPILLER, E
    FEDER, R
    TOPALIAN, J
    CASTELLANI, E
    ROMANKIW, L
    HERITAGE, M
    SOLID STATE TECHNOLOGY, 1976, 19 (04) : 62 - &
  • [45] TEMPERATURE STABILIZING DEVICES FOR X-RAY CHAMBERS
    TSYGAN, VT
    CHISTYAK.MF
    BYKOV, PN
    GUREVICH, MA
    SHCHEGOL.LA
    INDUSTRIAL LABORATORY, 1964, 30 (05): : 795 - &
  • [46] Fabrication of X-Ray Gratings Using X-Ray Lithography Technique for X-Ray Talbot Interferometer
    Noda, Daiji
    Tsujii, Hiroshi
    Takahashi, Naoki
    Hattori, Tadashi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (05) : H299 - H302
  • [47] Possibility of corrector plate tuning of x-ray focusing
    Talman, Richard
    APPLIED OPTICS, 2009, 48 (13) : 2522 - 2535
  • [48] Concepts for rapid tuning and switching of X-ray energies
    Jark, Werner
    Last, Arndt
    DAMAGE TO VUV, EUV, AND X-RAY OPTICS IV; AND EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE III, 2013, 8777
  • [49] Fast ultrasonic wavelength tuning in X-ray experiment
    Blagov, A. E.
    Pisarevskii, Yu. V.
    Koval'chuk, M. V.
    CRYSTALLOGRAPHY REPORTS, 2016, 61 (02) : 170 - 172
  • [50] Tuning of JPEG quantization matrices for X-ray images
    Maeder, AJ
    IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 351 - 357