The use of X-ray computed tomography (CT), exploiting both synchrotron and laboratory sources, has grown significantly over the last decade, driven primarily by improvements in spatial resolution, reduction in acquisition time and the increasing availability of laboratory X-ray CT systems. It is now able to provide highly accurate three-dimensional (3D) inspections of fibre architectures, manufacturing defects and in-service damage accumulation non-destructively, allowing the user to examine cross sections that would previously have required laborious and skilled mechanical sectioning with the potential for inducing damage or loss of material. Further, by repeated acquisition of 3D images, it has opened new opportunities for time-lapse studies. This feature article reviews the technical aspects relating to the X-ray CT imaging of composites such as obtaining sufficient contrast, examination of thin panels, sample size/resolution issues, quantification of damage and defects, and image-based modelling. The capability of X-ray CT to provide important information is considered across applications ranging from manufacturing processes, through tensile and compression loading to fatigue and impact damage. The complementary advantages of laboratory and synchrotron X-ray CT are examined with a view to identify new opportunities and challenges. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:305 / 319
页数:15
相关论文
共 50 条
  • [41] X-ray computed tomography application research
    Neel, ST
    Yancey, RN
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 497 - 502
  • [42] X-ray induced acoustic computed tomography
    Samant, P.
    Trevisi, L.
    Ji, X.
    Xiang, L.
    [J]. PHOTOACOUSTICS, 2020, 19 (19)
  • [43] X-Ray Computed Tomography Through Scatter
    Geva, Adam
    Schechner, Yoav Y.
    Chernyak, Yonatan
    Gupta, Rajiv
    [J]. COMPUTER VISION - ECCV 2018, PT XIV, 2018, 11218 : 37 - 54
  • [44] X-ray micro computed-tomography
    Baird, Emily
    Taylor, Gavin
    [J]. CURRENT BIOLOGY, 2017, 27 (08) : R289 - R291
  • [45] Signal statistics of x-ray computed tomography
    Whiting, BR
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 53 - 60
  • [46] NOISE LIMITATIONS IN X-RAY COMPUTED TOMOGRAPHY
    TRETIAK, OJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 477 - 480
  • [47] Ptychographic X-ray computed tomography at the nanoscale
    Martin Dierolf
    Andreas Menzel
    Pierre Thibault
    Philipp Schneider
    Cameron M. Kewish
    Roger Wepf
    Oliver Bunk
    Franz Pfeiffer
    [J]. Nature, 2010, 467 : 436 - 439
  • [48] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 772 - 774
  • [49] Development of dimensional X-ray computed tomography
    National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba
    Ibaraki
    305-8563, Japan
    [J]. Int. J. Autom. Technol., 5 (567-571):
  • [50] General formulation for X-ray computed tomography
    Wei, Yuchuan
    Yu, Hengyong
    Hsieh, Jiang
    Wang, Ge
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318