X-ray computed tomography of polymer composites

被引:450
|
作者
Garcea, S. C. [1 ]
Wang, Y. [1 ]
Withers, P. J. [1 ]
机构
[1] Univ Manchester, Sch Mat, Henry Moseley Xray Imaging Facil, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会; 欧洲研究理事会;
关键词
Polymer - matrix composites; Phase contrast; Damage mechanisms; Modelling; X-ray computed microtomography; FIBER-REINFORCED POLYMERS; PHASE-CONTRAST MICROTOMOGRAPHY; VELOCITY IMPACT DAMAGE; IN-SITU; HIGH-RESOLUTION; COMPRESSIVE FAILURE; FE ANALYSES; FATIGUE; FRACTURE; VOIDS;
D O I
10.1016/j.compscitech.2017.10.023
中图分类号
TB33 [复合材料];
学科分类号
摘要
The use of X-ray computed tomography (CT), exploiting both synchrotron and laboratory sources, has grown significantly over the last decade, driven primarily by improvements in spatial resolution, reduction in acquisition time and the increasing availability of laboratory X-ray CT systems. It is now able to provide highly accurate three-dimensional (3D) inspections of fibre architectures, manufacturing defects and in-service damage accumulation non-destructively, allowing the user to examine cross sections that would previously have required laborious and skilled mechanical sectioning with the potential for inducing damage or loss of material. Further, by repeated acquisition of 3D images, it has opened new opportunities for time-lapse studies. This feature article reviews the technical aspects relating to the X-ray CT imaging of composites such as obtaining sufficient contrast, examination of thin panels, sample size/resolution issues, quantification of damage and defects, and image-based modelling. The capability of X-ray CT to provide important information is considered across applications ranging from manufacturing processes, through tensile and compression loading to fatigue and impact damage. The complementary advantages of laboratory and synchrotron X-ray CT are examined with a view to identify new opportunities and challenges. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:305 / 319
页数:15
相关论文
共 50 条
  • [11] X-ray Computed Tomography Inspection of novel Ceramic Matrix Composites
    Brierley, Nick
    Chrzan, Karin
    Günnewig, Olaf
    Kessel, Fiona
    Backe, Daniel
    [J]. e-Journal of Nondestructive Testing, 2023, 28 (08):
  • [12] X-ray computed tomography study of kink bands in unidirectional composites
    Wang, Ying
    Burnett, Timothy L.
    Chai, Yuan
    Souti, Costas
    Hogg, Paul J.
    Withers, Philip J.
    [J]. COMPOSITE STRUCTURES, 2017, 160 : 917 - 924
  • [13] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    [J]. MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [14] Accuracy and reproducibility in x-ray computed tomography polymer gel dosimetry
    Maynard, E.
    Hilts, M.
    Heath, E.
    Jirasek, A.
    [J]. 9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [15] Industrial X-ray computed tomography
    Pechstein, Torsten
    [J]. TM-TECHNISCHES MESSEN, 2020, 87 (02) : 79 - 80
  • [16] Dynamic X-ray computed tomography
    Bonnet, S
    Koenig, A
    Roux, S
    Hugonnard, P
    Guillemaud, R
    Grangeat, P
    [J]. PROCEEDINGS OF THE IEEE, 2003, 91 (10) : 1574 - 1587
  • [17] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    [J]. 29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [18] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    [J]. INSIGHT, 1998, 40 (03) : 196 - 197
  • [19] Dose in x-ray computed tomography
    Kalender, Willi A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [20] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    [J]. BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67