A radioimmunoassay for the measurement of paclitaxel and taxanes in biological specimens using commercially available reagents

被引:0
|
作者
Guillemard, V
Landry, N
Pagé, M [1 ]
机构
[1] Univ Laval, Dept Med Biol, Fac Med, St Foy, PQ G1K 7P4, Canada
[2] BCM Dev Inc, Quebec City, PQ G1K 4C5, Canada
关键词
paclitaxel; taxanes; radioimmunoassay; culture broths;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We have developed a rapid and sensitive radioimmunoassay for the measurement of paclitaxel and related taxanes in biological specimens using commercially available reagents. The presence of paclitaxel competitively inhibited the binding of radioactive paclitaxel to polyclonal anti-taxane antibody or anti-taxane monoclonal antibody. When using polyclonal antibody, this method detected paclitaxel in concentrations as low as 0.87 nM and was also effective in 20% methanol. This radioimmunoassay is useful for the measurement of paclitaxel and taxanes in biological specimens like culture medium of paclitaxel-producing microorganisms and may be useful for the measurement of paclitaxel and related compounds in other potential natural sources.
引用
收藏
页码:1257 / 1259
页数:3
相关论文
共 50 条
  • [31] An Investigation of Measurement Techniques for Small Field Dosimetry Using Commercially Available Detectors
    Lim, S.
    Tang, G.
    LoSasso, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [32] A Saccharide Chemosensor Array Developed Based on an Indicator Displacement Assay Using a Combination of Commercially Available Reagents
    Sasaki, Yui
    Zhang, Zhoujie
    Minami, Tsuyoshi
    FRONTIERS IN CHEMISTRY, 2019, 7
  • [33] Scalable efficient expansion of mesenchymal stem cells in xeno free media using commercially available reagents
    Neil H Riordan
    Marialaura Madrigal
    Jason Reneau
    Kathya de Cupeiro
    Natalia Jiménez
    Sergio Ruiz
    Nelsy Sanchez
    Thomas E Ichim
    Francisco Silva
    Amit N Patel
    Journal of Translational Medicine, 13
  • [34] A standardized comparison of commercially available prion decontamination reagents using the Standard Steel-Binding Assay
    Edgeworth, Julie Ann
    Sicilia, Anita
    Linehan, Jackie
    Brandner, Sebastian
    Jackson, Graham S.
    Collinge, John
    JOURNAL OF GENERAL VIROLOGY, 2011, 92 : 718 - 726
  • [35] Scalable efficient expansion of mesenchymal stem cells in xeno free media using commercially available reagents
    Riordan, Neil H.
    Madrigal, Marialaura
    Reneau, Jason
    de Cupeiro, Kathya
    Jimenez, Natalia
    Ruiz, Sergio
    Sanchez, Nelsy
    Ichim, Thomas E.
    Silva, Francisco
    Patel, Amit N.
    JOURNAL OF TRANSLATIONAL MEDICINE, 2015, 13
  • [36] A NEW RADIOIMMUNOASSAY USING A COMMERCIALLY AVAILABLE SOLID SUPPORT FOR THE DETECTION OF IGE ANTIBODIES AGAINST MUSCLE-RELAXANTS
    GUILLOUX, L
    RICARDBLUM, S
    VILLE, G
    MOTIN, J
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 90 (02) : 153 - 159
  • [37] How to: Measuring blood cytokines in biological psychiatry using commercially available multiplex immunoassays
    Belzeaux, Raoul
    Lefebvre, Marie-Noelle
    Lazzari, Anne
    Le Carpentier, Tifenn
    Consoloni, Julia-Lou
    Zendjidjian, Xavier
    Abbar, Mocrane
    Courtet, Philippe
    Naudin, Jean
    Boucraut, Jose
    Gressens, Pierre
    Glaichenhaus, Nicolas
    Ibrahim, El Cherif
    PSYCHONEUROENDOCRINOLOGY, 2017, 75 : 72 - 82
  • [38] Comparison of four commercially available activated partial thromboplastin time reagents using a semi-automated coagulometer
    Shetty, S
    Ghosh, K
    Mohanty, D
    BLOOD COAGULATION & FIBRINOLYSIS, 2003, 14 (05) : 493 - 497
  • [39] One-step synthesis of 4,5-disubstituted pyrimidines using commercially available and inexpensive reagents
    Baran, Phil S.
    Shenvi, Ryan A.
    Nguyen, Steven A.
    HETEROCYCLES, 2006, 70 : 581 - +
  • [40] Gene transfer into primitive human hematopoietic progenitor cells using commercially available lipid transfection reagents.
    Musk, P
    Lawman, MJP
    Burges, AR
    Lawman, PD
    BLOOD, 1995, 86 (10) : 4002 - 4002