Effect of Torsional Loading of Nickel-Titanium Instruments on Cyclic Fatigue Resistance

被引:20
|
作者
Cheung, Gary Shun-Pan [1 ]
Oh, Seung-Hei [2 ]
Ha, Jung-Hong [3 ]
Kim, Sung Kyo [3 ]
Park, Se-Hee [4 ]
Kim, Hyeon-Cheol [2 ]
机构
[1] Univ Hong Kong, Area Endodont, Fac Dent, Hong Kong, Hong Kong, Peoples R China
[2] Pusan Natl Univ, Sch Dent, Dept Conservat Dent, Dent Res Inst, Yangsan 626810, Gyeongnam, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Conservat Dent, Taegu, South Korea
[4] Gangneung Wonju Natl Univ, Coll Dent, Dept Conservat Dent, Kangnung, South Korea
关键词
Cyclic fatigue resistance; nickel-titanium rotary file; preloading; superelasticity; torsional load; ROTARY FILES; FRACTURE; DEFECTS; PROFILE; STRESS;
D O I
10.1016/j.joen.2013.07.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the effect of torsional preload on the cyclic fatigue life of nickel-titanium rotary instruments. Methods: Pro File (#25/0.06) (Dentsply Maillefer, Ballaigues, Switzerland) and Pro Taper (F1; Dentsply Maillefer) were used. Each file was preloaded at 4 conditions (ie, no preloading and 25%, 50%, and 75% of mean ultimate torsional strength) of torsional prestress before the fatigue test. The torsional preloads were applied by securing 5 mm of the file tip while keeping the file straight, rotating it clockwise until the preset torque, and then returning to the original position. This motion was repeated until a preset number (10, 30, or 50) of repetitions were reached (n = 12). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal. Data were analyzed using 2-way analysis of variance and the Duncan post hoc comparison. The fractured fragment surfaces were examined under a scanning electron microscope for the topographic features of fractured instruments. Results: For both instruments, there was a significant effect because of the extent of torsional preloads. The 50% and 75% torsionally preloaded ProFile and all ProTaper preloading groups had a higher number of cycles to failure than the other group(s). There was little difference in the lateral view appearance between new and torsionally preloaded files. After cyclic fatigue testing, all preloaded instruments showed numerous microcracks adjacent to the fracture site on lateral view examination. The microcracks did not seem to follow the machining grooves on the instrument surface but rather ran irregularly. Conclusions: The torsional preloads within the superelastic limit of the material may improve the cyclic fatigue resistance of nickel-titanium rotary instruments.
引用
收藏
页码:1593 / 1597
页数:5
相关论文
共 50 条
  • [31] Response: Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary instruments
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1101 - 1101
  • [32] Influence of Combined Cyclic Fatigue and Torsional Stress on the Fracture Point of Nickel-Titanium Rotary Instruments
    Setzer, Frank C.
    Boehme, Christian P.
    JOURNAL OF ENDODONTICS, 2013, 39 (01) : 133 - 137
  • [33] Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments
    Murilo Priori Alcalde
    Marco Antonio Hungaro Duarte
    Clovis Monteiro Bramante
    Bruno Carvalho de Vasconselos
    Mario Tanomaru-Filho
    Juliane Maria Guerreiro-Tanomaru
    Jader Camilo Pinto
    Marcus Vinicius Reis Só
    Rodrigo Ricci Vivan
    Clinical Oral Investigations, 2018, 22 : 1865 - 1871
  • [34] Cyclic fatigue and torsional resistance of heat-treated One Curve compared with different nickel-titanium rotary instruments
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    ENDO-ENDODONTIC PRACTICE TODAY, 2019, 13 (03): : 247 - 253
  • [35] Angle of Insertion and Torsional Resistance of Nickel-Titanium Rotary Instruments
    Di Nardo, Dario
    Zanza, Alessio
    Seracchiani, Marco
    Donfrancesco, Orlando
    Gambarini, Gianluca
    Testarelli, Luca
    MATERIALS, 2021, 14 (13)
  • [36] Cyclic Fatigue and Torsional Resistance of Two New Nickel-Titanium Instruments Used in Reciprocation Motion: Reciproc Versus WaveOne
    Kim, Hyeon-Cheol
    Kwak, Sang-Won
    Cheung, Gary Shun-Pan
    Ko, Dae-Hoon
    Chung, Se-Min
    Lee, WooCheol
    JOURNAL OF ENDODONTICS, 2012, 38 (04) : 541 - 544
  • [37] Effect of Repeated Autoclaving on Cyclic Fatigue of Three Nickel-Titanium Rotary Instruments
    Elbatal, Laila M.
    El Batouty, Kariem Mostafa
    Obeid, Maram Mohamed
    ENDO-ENDODONTIC PRACTICE TODAY, 2016, 10 (01): : 15 - 22
  • [38] Influence of Cyclic Flexural Deformation on the Torsional Resistance of Controlled Memory and Conventional Nickel-titanium Instruments
    Pelaez Acosta, Eufemia Carolina
    Resende, Pedro Damas
    da Cunha Peixoto, Isabella Faria
    Joviano Pereira, Erika Sales
    Lopes Buono, Vicente Tadeu
    de Azevedo Bahia, Maria Guiomar
    JOURNAL OF ENDODONTICS, 2017, 43 (04) : 613 - 618
  • [39] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [40] A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments
    Plotino, Gianluca
    Grande, Nicola M.
    Cordaro, Massimo
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2009, 35 (11) : 1469 - 1476