Effect of Torsional Loading of Nickel-Titanium Instruments on Cyclic Fatigue Resistance

被引:20
|
作者
Cheung, Gary Shun-Pan [1 ]
Oh, Seung-Hei [2 ]
Ha, Jung-Hong [3 ]
Kim, Sung Kyo [3 ]
Park, Se-Hee [4 ]
Kim, Hyeon-Cheol [2 ]
机构
[1] Univ Hong Kong, Area Endodont, Fac Dent, Hong Kong, Hong Kong, Peoples R China
[2] Pusan Natl Univ, Sch Dent, Dept Conservat Dent, Dent Res Inst, Yangsan 626810, Gyeongnam, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Conservat Dent, Taegu, South Korea
[4] Gangneung Wonju Natl Univ, Coll Dent, Dept Conservat Dent, Kangnung, South Korea
关键词
Cyclic fatigue resistance; nickel-titanium rotary file; preloading; superelasticity; torsional load; ROTARY FILES; FRACTURE; DEFECTS; PROFILE; STRESS;
D O I
10.1016/j.joen.2013.07.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the effect of torsional preload on the cyclic fatigue life of nickel-titanium rotary instruments. Methods: Pro File (#25/0.06) (Dentsply Maillefer, Ballaigues, Switzerland) and Pro Taper (F1; Dentsply Maillefer) were used. Each file was preloaded at 4 conditions (ie, no preloading and 25%, 50%, and 75% of mean ultimate torsional strength) of torsional prestress before the fatigue test. The torsional preloads were applied by securing 5 mm of the file tip while keeping the file straight, rotating it clockwise until the preset torque, and then returning to the original position. This motion was repeated until a preset number (10, 30, or 50) of repetitions were reached (n = 12). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal. Data were analyzed using 2-way analysis of variance and the Duncan post hoc comparison. The fractured fragment surfaces were examined under a scanning electron microscope for the topographic features of fractured instruments. Results: For both instruments, there was a significant effect because of the extent of torsional preloads. The 50% and 75% torsionally preloaded ProFile and all ProTaper preloading groups had a higher number of cycles to failure than the other group(s). There was little difference in the lateral view appearance between new and torsionally preloaded files. After cyclic fatigue testing, all preloaded instruments showed numerous microcracks adjacent to the fracture site on lateral view examination. The microcracks did not seem to follow the machining grooves on the instrument surface but rather ran irregularly. Conclusions: The torsional preloads within the superelastic limit of the material may improve the cyclic fatigue resistance of nickel-titanium rotary instruments.
引用
收藏
页码:1593 / 1597
页数:5
相关论文
共 50 条
  • [21] The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments
    Dosanjh, Amandeep
    Paurazas, Susan
    Askar, Mazin
    JOURNAL OF ENDODONTICS, 2017, 43 (05) : 823 - 826
  • [22] Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
    Mize, SB
    Clement, DJ
    Pruett, JP
    Carnes, DL
    JOURNAL OF ENDODONTICS, 1998, 24 (12) : 843 - 847
  • [23] Cyclic fatigue testing of nickel-titanium endodontic instruments
    Pruett, JP
    Clement, DJ
    Carnes, DL
    JOURNAL OF ENDODONTICS, 1997, 23 (02) : 77 - 85
  • [24] Torsional fatigue resistance of pathfinding instruments manufactured from several nickel-titanium alloys
    Alcalde, M. P.
    Duarte, M. A. H.
    Bramante, C. M.
    Tanomaru-filho, M.
    Vasconcelos, B. C.
    So, M. V. R.
    Vivan, R. R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (06) : 697 - 704
  • [25] Effect of different axial speed patterns on cyclic fatigue resistance of rotary nickel-titanium instruments
    Thu, Myint
    Ebihara, Arata
    Maki, Keiichiro
    Nishijo, Miki
    Kimura, Shunsuke
    Nakatsukasa, Taro
    Kyaw, Moe Sandar
    Okiji, Takashi
    BMC ORAL HEALTH, 2022, 22 (01)
  • [26] Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation
    Pedulla, E.
    Lizio, A.
    Scibilia, M.
    Grande, N. M.
    Plotino, G.
    Boninelli, S.
    Rapisarda, E.
    Lo Giudice, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (02) : 194 - 201
  • [27] Effect of different axial speed patterns on cyclic fatigue resistance of rotary nickel-titanium instruments
    Myint Thu
    Arata Ebihara
    Keiichiro Maki
    Miki Nishijo
    Shunsuke Kimura
    Taro Nakatsukasa
    Moe Sandar Kyaw
    Takashi Okiji
    BMC Oral Health, 22
  • [28] Cyclic fatigue resistance of Nickel-Titanium reciprocating instruments tested with an innovative kinematics
    Iacono, Francesco
    Pirani, Chiara
    Generali, Luigi
    Gatto, Maria Rosaria
    Gandolfi, Maria Giovanna
    Prati, Carlo
    GIORNALE ITALIANO DI ENDODONZIA, 2018, 32 (01): : 42 - 46
  • [29] Cyclic fatigue resistance of novel Genius and Edgefile nickel-titanium reciprocating instruments
    Emerenciano Bueno, Carlos Roberto
    Sandoval Cury, Marina Tolomei
    Veiga Vasques, Ana Maria
    Sivieri-Araujo, Gustavo
    Jacinto, Rogerio Castilho
    Gomes-Filho, Joao Eduardo
    Angelo Cintra, Luciano Tavares
    Dezan-Junior, Eloi
    BRAZILIAN ORAL RESEARCH, 2019, 33
  • [30] Cyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instruments