Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus

被引:24
|
作者
Del Baldo, Francesca [1 ]
Canton, Claudia [1 ]
Testa, Silvia [1 ]
Swales, Harry [2 ]
Drudi, Ignazio [3 ]
Golinelli, Stefania [1 ]
Fracassi, Federico [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Via Tolara di Sopra 50, I-40064 Bologna, Italy
[2] Univ Liverpool, Small Anim Teaching Hosp, Leahurst Campus, Wirral, Merseyside, England
[3] Univ Bologna, Dept Stat Sci, Bologna, Italy
关键词
canine; diabetes mellitus; FreeStyle Libre; interstitial glucose; TO-DAY VARIATION; GLYCEMIC VARIABILITY; INTERSTITIAL GLUCOSE; SENSING TECHNOLOGY; GROWTH-HORMONE; REAL-LIFE; INSULIN; TYPE-1; HYPOGLYCEMIA; MULTICENTER;
D O I
10.1111/jvim.15930
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals Twenty dogs with diabetes mellitus. Methods Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
引用
收藏
页码:2296 / 2305
页数:10
相关论文
共 50 条
  • [1] Comparison of a Continuous Glucose Monitoring System with a Portable Blood Glucose Meter to Determine Insulin Dose in Cats with Diabetes Mellitus
    Dietiker-Moretti, S.
    Mueller, C.
    Sieber-Ruckstuhl, N.
    Tschuor, F.
    Osto, M.
    Franchini, M.
    Ackermann, M.
    Lutz, T. A.
    Reusch, C. E.
    Zini, E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (05) : 1084 - 1088
  • [2] Portable blood glucose meters as a means of monitoring blood glucose concentrations in dogs and cats with diabetes mellitus
    Stein, JE
    Greco, DS
    CLINICAL TECHNIQUES IN SMALL ANIMAL PRACTICE, 2002, 17 (02): : 70 - 72
  • [3] The Influence of Skin Thickness on Flash Glucose Monitoring System Accuracy in Dogs with Diabetes Mellitus
    Del Baldo, Francesca
    Diana, Alessia
    Canton, Claudia
    Linta, Nikolina
    Chiocchetti, Roberto
    Fracassi, Federico
    ANIMALS, 2021, 11 (02): : 1 - 12
  • [4] Comparison of an Intermittently Scanned (Flash) Continuous Glucose Monitoring System to Standard Self-Monitoring of Capillary Blood Glucose in Gestational Diabetes Mellitus
    Hussain, Farrah N.
    Raymond, Samantha
    Feldman, Kristina M.
    Scarpelli-Shchur, Sophia
    Strauss, Tirtza S.
    Al-Ibraheemi, Zainab
    Brustman, Lois
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (11) : 1149 - 1157
  • [5] Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose
    Babaya, Naru
    Noso, Shinsuke
    Hiromine, Yoshihisa
    Taketomo, Yasunori
    Niwano, Fumimaru
    Yoshida, Sawa
    Yasutake, Sara
    Kawabata, Yumiko
    Ikegami, Hiroshi
    JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (05) : 1222 - 1229
  • [6] An Evaluation of the Accuracy of a Flash Glucose Monitoring System in Children with Diabetes in comparison with Venous Blood Glucose
    Cao, Bingyan
    Wang, Rui
    Gong, Chunxiu
    Wu, Di
    Su, Chang
    Chen, Jiajia
    Yi, Yajun
    Liu, Min
    Liang, Xuejun
    Li, Wenjing
    JOURNAL OF DIABETES RESEARCH, 2019, 2019
  • [7] An evaluation of the accuracy of a flash glucose monitoring system in children with diabetes in comparison with venous blood glucose
    Cao, Bingyan
    Wang, Rui
    Gong, Chunxiu
    Wu, Di
    Su, Chang
    Chen, Jiajia
    Yi, Yajun
    Liu, Min
    Liang, Xuejun
    Li, Wenjing
    HORMONE RESEARCH IN PAEDIATRICS, 2019, 91 : 287 - 287
  • [8] Development of the portable blood glucose meter for self-monitoring of blood glucose
    Li, Qi
    Yuan, Jingqi
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6735 - 6738
  • [9] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
  • [10] Monitoring of Diabetes Mellitus Using the Flash Glucose Monitoring System: The Owners' Point of View
    Re, Mariachiara
    Del Baldo, Francesca
    Tardo, Antonio Maria
    Fracassi, Federico
    VETERINARY SCIENCES, 2023, 10 (03)