A novel high-resolution 2D silicon array detector for small field dosimetry with FFF photon beams

被引:28
|
作者
Biasi, G. [1 ]
Petasecca, M. [1 ]
Guatelli, S. [1 ]
Hardcastle, N. [2 ]
Carolan, M. [1 ,4 ]
Perevertaylo, V. [5 ]
Kron, T. [1 ,2 ,3 ]
Rosenfeld, A. B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Peter MacCallum Canc Ctr, Melbourne, Vic, Australia
[3] Univ Melbourne, Sir Peter MacCallum Canc Inst, Melbourne, Vic, Australia
[4] Wollongong Hosp, Illawarra Canc Care Ctr, Wollongong, NSW, Australia
[5] SPA BIT, Kiev, Ukraine
基金
英国医学研究理事会;
关键词
SRT; SBRT; FFF; Small field dosimetry QA; 2D monolithic silicon array detector; FLATTENING FILTER; QUALITY-ASSURANCE; DIODE; DEPENDENCE; PLATE;
D O I
10.1016/j.ejmp.2017.12.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Flattening filter free (FFF) beams are increasingly being considered for stereotactic radiotherapy (SRT). For the first time, the performance of a monolithic silicon array detector under 6 and 10 MV FFF beams was evaluated. The dosimeter, named "Octa" and designed by the Centre for Medical Radiation Physics (CMRP), was tested also under flattened beams for comparison. Methods: Output factors (OFs), percentage depth-dose (PDD), dose profiles (DPs) and dose per pulse (DPP) dependence were investigated. Results were benchmarked against commercially available detectors for small field dosimetry. Results: The dosimeter was shown to be a 'correction-free' silicon array detector for OFs and PDD measurements for all the beam qualifies investigated. Measured OFs were accurate within 3% and PDD values within 2% compared against the benchmarks. Cross-plane, in-plane and diagonal DPs were measured simultaneously with high spatial resolution (0.3 mm) and real time read-out. A DPP dependence (24% at 0.021 mGy/pulse relative to 0.278 mGy/pulse) was found and could be easily corrected for in the case of machine specific quality assurance applications. Conclusions: Results were consistent with those for monolithic silicon array detectors designed by the CMRP and previously characterized under flattened beams only, supporting the robustness of this technology for relative dosimetry for a wide range of beam qualifies and dose per pulses. In contrast to its predecessors, the design of the Octa offers an exhaustive high-resolution 2D dose map characterization, making it a unique real-time radiation detector for small field dosimetry for field sizes up to 3 cm side.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [21] A novel 2D position sensitive silicon detector with micron resolution for heavy ion tracking
    Yu, B
    Beuttenmuller, R
    Chen, W
    Elliott, DC
    Li, Z
    Mead, JA
    Radeka, V
    Vazquez, ME
    Brown, KA
    Rusek, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1165 - 1169
  • [22] High-resolution measurements of small field beams using polymer gels
    Wong, C. J.
    Ackerly, T.
    He, C.
    Patterson, W.
    Powell, C. E.
    Ho, A.
    Qiao, G.
    Solomon, D. H.
    Meder, R.
    Geso, M.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (10) : 1160 - 1164
  • [23] High-resolution dynamic imaging system based on a 2D optical phased array
    Wang, Zihao
    Sun, Yanling
    Liao, Jiali
    Wang, Chen
    Cao, Rui
    JIn, Li
    Cao, Changqing
    OPTICS EXPRESS, 2021, 29 (24): : 39342 - 39351
  • [24] High-resolution imaging 1D and 2D solid-state detector systems
    Tumer, Tumay O.
    Cajipe, Victoria B.
    Clajus, Martin
    Hayakawa, Satoshi
    Volkovskii, Alexander
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319
  • [25] A 2D detector array for relative dosimetry and beam steering for FLASH radiotherapy with electrons
    Schonfeld, Andreas A.
    Hildreth, Jeff
    Bourgouin, Alexandra
    Flatten, Veronika
    Kozelka, Jakub
    Simon, William
    Schueller, Andreas
    MEDICAL PHYSICS, 2025, 52 (03) : 1845 - 1857
  • [26] 2D optoacoustic array for high resolution imaging
    Ashkenazi, S.
    Witte, R. S.
    Kim, K.
    Huang, S. -W.
    Hou, Y.
    O'Donnell, M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2006, 2006, 6086
  • [27] High-Resolution Scanning Probe Nanolithography of 2D Materials: Novel Nanostructures
    Rani, Ekta
    Wong, Lu Shin
    ADVANCED MATERIALS TECHNOLOGIES, 2019, 4 (07)
  • [28] Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison
    Pappas, E.
    Maris, T. G.
    Zacharopoulou, F.
    Papadakis, A.
    Manolopoulos, S.
    Green, S.
    Wojnecki, C.
    MEDICAL PHYSICS, 2008, 35 (10) : 4640 - 4648
  • [29] Verification of small-field VMAT plans using a 2D detector array in a rotational phantom
    Swinnen, A.
    Ollers, M.
    Roijen, E.
    Nijsten, S.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S738 - S739
  • [30] A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
    Guillot, Mathieu
    Beaulieu, Luc
    Archambault, Louis
    Beddar, Sam
    Gingras, Luc