A novel high-resolution 2D silicon array detector for small field dosimetry with FFF photon beams

被引:28
|
作者
Biasi, G. [1 ]
Petasecca, M. [1 ]
Guatelli, S. [1 ]
Hardcastle, N. [2 ]
Carolan, M. [1 ,4 ]
Perevertaylo, V. [5 ]
Kron, T. [1 ,2 ,3 ]
Rosenfeld, A. B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Peter MacCallum Canc Ctr, Melbourne, Vic, Australia
[3] Univ Melbourne, Sir Peter MacCallum Canc Inst, Melbourne, Vic, Australia
[4] Wollongong Hosp, Illawarra Canc Care Ctr, Wollongong, NSW, Australia
[5] SPA BIT, Kiev, Ukraine
基金
英国医学研究理事会;
关键词
SRT; SBRT; FFF; Small field dosimetry QA; 2D monolithic silicon array detector; FLATTENING FILTER; QUALITY-ASSURANCE; DIODE; DEPENDENCE; PLATE;
D O I
10.1016/j.ejmp.2017.12.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Flattening filter free (FFF) beams are increasingly being considered for stereotactic radiotherapy (SRT). For the first time, the performance of a monolithic silicon array detector under 6 and 10 MV FFF beams was evaluated. The dosimeter, named "Octa" and designed by the Centre for Medical Radiation Physics (CMRP), was tested also under flattened beams for comparison. Methods: Output factors (OFs), percentage depth-dose (PDD), dose profiles (DPs) and dose per pulse (DPP) dependence were investigated. Results were benchmarked against commercially available detectors for small field dosimetry. Results: The dosimeter was shown to be a 'correction-free' silicon array detector for OFs and PDD measurements for all the beam qualifies investigated. Measured OFs were accurate within 3% and PDD values within 2% compared against the benchmarks. Cross-plane, in-plane and diagonal DPs were measured simultaneously with high spatial resolution (0.3 mm) and real time read-out. A DPP dependence (24% at 0.021 mGy/pulse relative to 0.278 mGy/pulse) was found and could be easily corrected for in the case of machine specific quality assurance applications. Conclusions: Results were consistent with those for monolithic silicon array detectors designed by the CMRP and previously characterized under flattened beams only, supporting the robustness of this technology for relative dosimetry for a wide range of beam qualifies and dose per pulses. In contrast to its predecessors, the design of the Octa offers an exhaustive high-resolution 2D dose map characterization, making it a unique real-time radiation detector for small field dosimetry for field sizes up to 3 cm side.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [1] A 2D silicon detector array for quality assurance in small field dosimetry: DUO
    Al Shukaili, Khalsa
    Petasecca, Marco
    Newall, Matthew
    Espinoza, Anthony
    Perevertaylo, Vladimir L.
    Corde, Stephanie
    Lerch, Michael
    Rosenfeld, Anatoly B.
    MEDICAL PHYSICS, 2017, 44 (02) : 628 - 636
  • [2] A silicon diode array detector for small field dosimetry with flattening filter free beams
    Biasi, G.
    Petasecca, M.
    Guatelli, S.
    Kron, T.
    Rosenfeld, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S919 - S920
  • [3] Evaluation of a Novel 2D Detector Array for Patient Plan Verification in Conventional and Flattening Filter-Free (FFF) Photon Beams in Clinical Conditions
    Sekar, Y.
    Thoelking, J.
    Celi, J.
    Lohr, F.
    Wenz, F.
    Wertz, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S740 - S740
  • [4] A high resolution 2D array detector system for small-field MRI-linac applications
    Gargett, Maegan
    Oborn, Brad
    Alnaghy, Sarah J.
    Causer, Trent
    Petasecca, Marco
    Rosenfeld, Anatoly B.
    Metcalfe, Peter
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (03):
  • [5] Novel epitaxial silicon array for small field dosimetry
    Talamonti, C.
    Zani, M.
    Menichelli, D.
    Friedl, F.
    Bisello, F.
    Bonomo, P.
    Bruzzi, M.
    Paiar, F.
    Scaringella, M.
    Bucciolini, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S416 - S417
  • [6] STARLAB DETECTOR SYSTEM - A WIDE FIELD, HIGH-RESOLUTION, PHOTON-COUNTING ARRAY
    GORHAM, R
    RODGERS, A
    STAPINSKI, T
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 331 : 490 - 497
  • [7] Technical Note: Angular dependence of a 2D monolithic silicon diode array for small field dosimetry
    Stansook, Nauljun
    Utitsarn, Kananan
    Petasecca, Marco
    Newall, Matthew K.
    Duncan, Mitchell
    Nitschke, Kym
    Carolan, Martin
    Metcalfe, Peter
    Lerch, Michael L. F.
    Perevertaylo, Vladimir L.
    Tome, Wolfgang A.
    Rosenfeld, Anatoly B.
    MEDICAL PHYSICS, 2017, 44 (08) : 4313 - 4321
  • [8] Liquid scintillator for 2D dosimetry for high-energy photon beams
    Poenisch, Falk
    Archambault, Louis
    Briere, Tina Marie
    Sahoo, Narayan
    Mohan, Radhe
    Beddar, Sam
    Gillin, Michael T.
    MEDICAL PHYSICS, 2009, 36 (05) : 1478 - 1485
  • [9] SILICON TECHNOLOGY IN ION DETECTION - A HIGH-RESOLUTION DETECTOR ARRAY
    BIRKINSHAW, K
    LANGSTAFF, DP
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03): : 193 - 206
  • [10] Electron Beam Dosimetry Using a 2D Detector Array
    Srivastava, S.
    Das, I.
    MEDICAL PHYSICS, 2009, 36 (06)