Correction of geometrical distortions in video based electronic portal imaging systems

被引:0
|
作者
Hilsebecher, J [1 ]
Bortfeld, T [1 ]
Schlegel, W [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Phys Med, D-6900 Heidelberg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In clinical routine electronic portal imaging systems are most commonly used for simple therapy verification and documentation. However this method has a much greater potential. Since most video based portal imaging systems deliver images, which are spoiled by geometric distortions [2,4], additional effort is necessary for image corrections. These can be done to a degree that allows absolute measurements of clinically relevant information as for example leaf positions of a multileaf collimator. Both the effort necessary for the corrections and the inaccuracies remaining afterwards strongly depend on the mechanical stability of the setup and image quality. While the mechanical aspects are the responsibility of the manufacturer the main influence on the image quality - noise - can be reduced by averaging of several images.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [31] State of the art in electronic portal imaging
    Shalev, S
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 27 - 30
  • [32] Clinical use of electronic portal imaging
    Herman, MG
    SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (03) : 157 - 167
  • [33] CORRECTION OF RANDOM DISTORTIONS IN OPERATIVE COMMUNICATION SYSTEMS
    VINOGRADOV, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (06): : 1354 - +
  • [34] Correction of geometrical effects on fluorescence imaging of tissue
    Qu, JY
    Hua, JW
    Huang, ZJ
    OPTICS COMMUNICATIONS, 2000, 176 (4-6) : 319 - 326
  • [35] IMRT verification with a camera-based electronic portal imaging system
    Partridge, M
    Symonds-Tayler, JRN
    Evans, PM
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12): : N183 - N196
  • [36] HOW TO IMPROVE IMAGE QUALITY OF ELECTRONIC PORTAL IMAGING DEVICES WITH MLG CALIBRATION AND TEMPERATURE CORRECTION
    Huber, S.
    Mitterlechner, B.
    Mooslechner, M.
    Sedlmayer, F.
    Deutschmann, H.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S132 - S132
  • [37] Development of a novel electronic portal imaging device based on cherenkov radiation
    Pang, G.
    Mei, X.
    Rowlands, J. A.
    MEDICAL PHYSICS, 2007, 34 (06) : 2526 - 2526
  • [38] Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation
    Van de Steene, J
    Van den Heuvel, F
    Bel, A
    Verellen, D
    De Mey, J
    Noppen, M
    De Beukeleer, M
    Storme, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04): : 967 - 976
  • [39] Imaging bypass system with correction for primary mirror distortions
    Vasil'ev, MV
    Berenberg, VA
    Leshchev, AA
    Semenov, PM
    Venediktov, VY
    FREE-SPACE LASER COMMUNICATION TECHNOLOGIES XI, 1999, 3615 : 362 - 368
  • [40] Correction of Shearing Distortions in Echo-Planar Imaging
    Liu, Guoxiang
    Oshio, Koichi
    Ogawa, Seiji
    Murata, Tsutomu
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (07) : 2628 - 2634