Design of Wireless Force Sensing Module of Vascular Interventional Robot

被引:0
|
作者
Fu, Zhuang [1 ]
Yao, Jianfeng [1 ]
Fu, Zeyu [1 ]
Sui, Chenxin [1 ]
Fei, Jian [2 ]
机构
[1] Shanghai Jiao Tong Univ, State Key Lab Mech Syst & Vibrat, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Vascular interventional robot; Force sensing; Kalman filter; EXPERIENCE;
D O I
10.1007/978-3-031-13835-5_32
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Force information is an indispensable and essential factor in vascular interventional surgery, which significantly affects the accuracy and safety of the procedure. This paper designs a new force sensing module for the vascular interventional robot, which measures the propulsion resistance and twisting torque during catheter and guidewire actuation. The FEA simulation is used to analyze the stress of the elastic body, and to establish the appropriate structure statically. The voltage signal is amplified, filtered and then transmitted wirelessly via Bluetooth. Finally, the force sensing module is subjected to a static calibration experiment, and the acquired signal is filtered using the Kalman filter algorithm. The experimental results have shown that the force sensing module exhibits good linearity and accuracy.
引用
收藏
页码:357 / 366
页数:10
相关论文
共 50 条
  • [31] An Interventional Surgical Robot System with Force Feedback
    Jia, Feiyu
    Guo, Shuxiang
    Wang, Yuan
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2015, : 632 - 637
  • [32] Design of a Force Sensing Hand for the R1 Humanoid Robot
    Sureshbabu, Anand Vazhapilli
    Maggiali, Marco
    Metta, Giorgio
    Parmiggiani, Alberto
    2017 IEEE-RAS 17TH INTERNATIONAL CONFERENCE ON HUMANOID ROBOTICS (HUMANOIDS), 2017, : 703 - 709
  • [33] Design of module of moving robot
    Hatala, Michal
    Mičko, Miroslav
    Olexa, Ľubomír
    Michalik, Peter
    Čisár, Ján
    Kokuľa, Pavel
    Applied Mechanics and Materials, 2014, 616 : 93 - 100
  • [34] Design and characteristics evaluation of a novel VR-based robot-assisted catheterization training system with force feedback for vascular interventional surgery
    Guo, Jian
    Guo, Shuxiang
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (08): : 3107 - 3116
  • [35] Design and characteristics evaluation of a novel VR-based robot-assisted catheterization training system with force feedback for vascular interventional surgery
    Jian Guo
    Shuxiang Guo
    Microsystem Technologies, 2017, 23 : 3107 - 3116
  • [36] Design of Cross-Country Robot Control System Based on Wireless Communication Module
    Yan, Shiyu
    Liu, Chong
    Li, Yungong
    Wang, Hong
    MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2012, 2-3 : 269 - 272
  • [37] Optimal Design of Dynamic Wireless Power Transmitting Array Module in Random Position of Robot
    Xue M.
    Yang Q.
    Zhang P.
    Guo J.
    Hou H.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (24): : 6319 - 6331
  • [38] The Design of Wireless Communication Module
    Gao, Dongwei
    Ma, Qinggong
    Zhou, Xiaoling
    Li, Junhua
    KEY ENGINEERING MATERIALS AND COMPUTER SCIENCE, 2011, 320 : 475 - 480
  • [39] Characteristics Evaluation of the Vascular Interventional Surgery Robot in the Simulated Vascular Environment
    Guo, Jian
    Jin, Xiaoliang
    Guo, Shuxiang
    Du, Wenxuan
    2018 13TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2018, : 141 - 146
  • [40] Design A Novel of Path Planning Method for The Vascular Interventional Surgery Robot based on DWA Model
    Guo, Jian
    Zhao, Han
    Guo, Shuxiang
    2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 1322 - 1327