A Correlation Study of MOL Electrical Test Method with its Physical Analysis

被引:0
|
作者
Cahyadi, T. [1 ]
Chen, F. [2 ]
Jiang, H. [1 ]
Mittl, S. [2 ]
Chua, E. C. [1 ]
机构
[1] GLOBALFOUNDRIES US Inc, 400 Stone Break Rd Ext, Malta, NY 12020 USA
[2] IBM Microelect, Essex Jct, VT 05452 USA
关键词
Middle-of-Line; MOL; VRDB; PC-to-CA reliability; PC-to-CA space; local variation; global variation; fatal-area ratio; PC-to-CA overlay;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A correlation study of middle-of-line (MOL) electrical test method with its inline polysilicon gate (PC) and the diffusion contacts (CA) photolithography overlay data is presented in this paper for wafers fabricated by gate first CMOS process at 32nm. The physical analysis by scanning electron microscopy (SEM) further confirmed the accuracy of the electrical test method in explaining the physical values of global shift and local shift. Therefore, this electrical PC-to-CA testing methodology can be adopted cost effectively for an accurate MOL reliability assessment and process diagnostics in a timely and comprehensive manner.
引用
收藏
页码:217 / 220
页数:4
相关论文
共 50 条
  • [31] Fatigue Index, Haemoglobin Level and Physical Fitness: A Correlation Analysis Study
    Sepriadi
    Syafruddin
    Khairuddin, hemoglobina
    Rifki, Muhamad Sazeli
    Alnedral
    Bafirman
    Ihsan, Nurul
    Eldawaty
    Hassanah, Puti
    Yaslindo
    Edwarsyah
    RETOS-NUEVAS TENDENCIAS EN EDUCACION FISICA DEPORTE Y RECREACION, 2024, (56): : 864 - 869
  • [32] Shorten Electrical Test Time with Double Ramping Test Method
    Keong, Lee Tai
    Yuan, Ho Tze
    PROCEEDINGS OF THE 2010 34TH IEEE/CPMT INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY CONFERENCE (IEMT 2010), 2011,
  • [33] Analysis of test method for physical model test of mining based on optical fiber sensing technology detection
    Chai, Jing
    Du, Wengang
    Yuan, Qiang
    Zhang, Dingding
    OPTICAL FIBER TECHNOLOGY, 2019, 48 : 84 - 94
  • [34] Physical activity and its correlation to diabetic retinopathy
    Praidou, Anna
    Harris, Martin
    Niakas, Dimitrios
    Labiris, Georgios
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2017, 31 (02) : 456 - 461
  • [35] THE PHYSICAL SUBSTANCE OF THE METHOD OF ELECTRICAL IMPEDANCE SPECTROMETRY
    Parilkova, Jana
    Sevcik, Robert
    EUREKA 2010: 1ST CONFERENCE AND WORKING SESSION, 2010, : 23 - 43
  • [36] Correlation method of coupling aerodynamic loading for high frequency force balance test and its applications
    Zhang L.
    Xie Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 (08): : 10 - 17
  • [37] Test method and its course
    不详
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1996, 23 : 9 - 14
  • [38] Correlation of Electrical Resistivity Test with the Geotechnical Parameters of Sandy Soil
    Naseem, Ahsan
    Jalal, Fazal-E
    De Backer, Hans
    Schotte, Ken
    Kashif, Muhammad
    RECENT ADVANCES IN GEO-ENVIRONMENTAL ENGINEERING, GEOMECHANICS AND GEOTECHNICS, AND GEOHAZARDS, 2019, : 191 - 193
  • [39] Study on the Intelligent Analysis Method of the Infrared Detection of Electrical Equipment
    Xin Jianbo
    Kang Chen
    Chen Tian
    Fu Xiaohua
    Zhou Longwu
    2018 3RD INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE), 2018, : 500 - 504
  • [40] Bilateral language representation by Wada test: Correlation with electrical stimulation
    Schuele, SU
    Skidmore, C
    Frazier, T
    Moeddel, G
    Dinner, DS
    NEUROLOGY, 2005, 64 (06) : A153 - A153