DEVELOPMENT AND VALIDATION OF THE REALISTIC ANTHROPOMORPHIC FLEXIBLE (RAF) PHANTOM

被引:10
|
作者
Lombardo, Pasquale A. [1 ,2 ]
Vanhavere, Filip [3 ]
Lebacq, Anne L. [4 ]
Struelens, Lara [1 ]
Bogaerts, Ria [2 ]
机构
[1] SCK CEN, Res Dosimetr Applicat, Boeretang 200, B-2400 Mol, Belgium
[2] Katholieke Univ Leuven, Lab Expt Radiotherapy, Herestr 49, B-3000 Leuven, Belgium
[3] SCK CEN, Radiat Protect Dosimetry & Calibrat, Boeretang 200, B-2400 Mol, Belgium
[4] SCK CEN, Dosimetr & Calibrat Serv, Boeretang 200, B-2400 Mol, Belgium
来源
HEALTH PHYSICS | 2018年 / 114卷 / 05期
关键词
Dose; organ; dose; skin; Monte Carlo; radiation dose; COMPUTATIONAL PHANTOMS; PROTECTION; CONVERSION; DOSIMETRY; MODELS;
D O I
10.1097/HP.0000000000000805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Voxel phantoms developed by segmenting computed tomography images are known to be more anatomically accurate than mathematical phantoms. However, due to their lack of flexibility and the complexity of voxel datasets, the use of voxel phantoms in dosimetry is often impractical. This paper describes the development of the realistic anthropomorphic flexible (RAF) polygonal mesh phantom, a novel phantom based on Boundary Representation (B-Rep) that merges anatomical accuracy and flexibility. Rather than using segmentation of tomography images, the modeling of the phantom's organs was based on freely and commercially available anatomical atlases, ICRP 89, and recent medical literature. To validate the phantom, a high-resolution voxel version was created for the MCNPx transport code. The voxelized RAF phantom was validated by comparing it with the ICRP 110 male phantom for external irradiations with parallel beams of photons and electrons. Dose coefficients obtained from simulations with the RAF phantom were compared with those from ICRP Publication 116. Relevant differences in organ doses were found.
引用
收藏
页码:486 / 499
页数:14
相关论文
共 50 条
  • [1] A realistic anthropomorphic dynamic heart phantom
    Haddad, R
    Clarysse, P
    Orkisz, M
    Croisille, P
    Revel, D
    Magnin, IE
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 801 - 804
  • [2] Development of an anthropomorphic rodent phantom
    McDougald, W.
    Weir, N.
    Collins, R.
    Tavares, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S259 - S259
  • [3] DEVELOPMENT OF AN ANTHROPOMORPHIC CHEST PHANTOM
    CALDWELL, CB
    MAWDSLEY, GE
    YAFFE, MJ
    MEDICAL PHYSICS, 1987, 14 (04) : 714 - 714
  • [4] DEVELOPMENT OF AN ANTHROPOMORPHIC BREAST PHANTOM
    CALDWELL, CB
    YAFFE, MJ
    MEDICAL PHYSICS, 1990, 17 (02) : 273 - 280
  • [5] ANTHROPOMORPHIC US BREAST PHANTOM WITH A REALISTIC HETEROGENEOUS GLANDULAR REGION
    MADSEN, EL
    FRANK, GR
    LORRAINE, PW
    DONG, F
    RADIOLOGY, 1995, 197 : 190 - 191
  • [6] Development of An Anthropomorphic Deformable Lung Phantom
    Shin, D.
    Kang, S.
    Kim, K.
    Kim, T.
    Kim, D.
    Yoon, D.
    Yamamoto, T.
    Suh, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 3300 - 3300
  • [7] Development of a realistic, dynamic digital brain phantom for CT Perfusion validation
    Divel, Sarah E.
    Segars, W. Paul
    Christensen, Soren
    Wintermark, Max
    Lansberg, Maarten G.
    Pelc, Norbert J.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [8] Anthropomorphic Durable Realistic Knee Phantom for Testing Electromagnetic Imaging Systems
    Sultan, Kamel S.
    Mohammed, Beadaa
    Mills, Paul C.
    Abbosh, Amin
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2021, 5 (02): : 132 - 138
  • [9] Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research
    Merken, Karen
    Monnens, Janne
    Marshall, Nicholas
    Johan, Nuyts
    Brasil, Danieli Moura
    Santaella, Gustavo Machado
    Politis, Constantinus
    Jacobs, Reinhilde
    Bosmans, Hilde
    MEDICAL PHYSICS, 2023, 50 (11) : 6714 - 6736
  • [10] Design, construction and evaluation of an anthropomorphic head phantom with realistic susceptibility artifacts
    Shmueli, Karin
    Thomas, David L.
    Ordidge, Roger J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) : 202 - 207