A microcontroller-based lock-in amplifier for sub-milliohm resistance measurements

被引:26
|
作者
Bengtsson, Lars E. [1 ]
机构
[1] Univ Gothenburg, Dept Phys, SE-41296 Gothenburg, Sweden
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 07期
关键词
All Open Access; Bronze;
D O I
10.1063/1.4731683
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a novel approach to the design of a digital ohmmeter with a resolution of <60 mu Omega based on a general-purpose microcontroller and a high-impedance instrumentation amplifier only. The design uses two digital I/O-pins to alternate the current through the sample resistor and combined with a proper firmware routine, the design is a lock-in detector that discriminates any signal that is out of phase/frequency with the reference signal. This makes it possible to selectively detect the mu V drop across sample resistors down to 55.6 mu Omega using only the current that can be supplied by the digital output pins of a microcontroller. This is achieved without the need for an external reference signal generator and does not rely on the computing processing power of a digital signal processor. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4731683]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Lock-in amplifier based peak force infrared microscopy
    Dorsa, Andrea
    Xie, Qing
    Wagner, Martin
    Xu, Xiaoji G.
    [J]. ANALYST, 2023, 148 (02) : 227 - 232
  • [22] Digital lock-in amplifier based on DSP and sampling ADC
    Hu, Shaomin
    Zhang, Guangfa
    [J]. Shu Ju Cai Ji Yu Chu Li/Journal of Data Acquisition & Processing, 2000, 15 (02): : 222 - 225
  • [23] Enhanced Frequency Resolution Two-Channel Two-Phase Microcontroller Lock-In Amplifier
    Alexandrino Alves, Gustavo Marcati
    Mansano, Ronaldo Domingues
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [24] Implementation of Digital Lock-in Amplifier Based on System Generator
    Wang, Qingfeng
    Zheng, Hong
    Jiang, Meng
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP), 2016, : 636 - 640
  • [25] LOCK-IN AMPLIFIER BASED ON A SYNCHRONOUSLY CLOCKED TRANSVERSAL FILTER
    CODDING, EG
    [J]. ANALYTICAL CHEMISTRY, 1979, 51 (12) : 1981 - 1986
  • [26] INSTRUMENTATION FOR AC VOLTAMMETRY BASED ON A DIGITAL LOCK-IN AMPLIFIER
    CURRAN, DJ
    KINGSLEY, ED
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 183 (MAR): : 14 - ANYL
  • [27] Amplitude noise spectrum of a lock-in amplifier: Application to microcantilever noise measurements
    Ruppert, Michael G.
    Bartlett, Nathan J.
    Yong, Yuen K.
    Fleming, Andrew J.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2020, 312
  • [28] SELECTION OF DWELL TIME WHEN USING A LOCK-IN AMPLIFIER IN A SEQUENCE OF MEASUREMENTS
    DIJULIO, SS
    KNUTH, EL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (07): : 1154 - 1156
  • [29] Two Simple Capacitance Sensing Solutions Microcontroller-Based Measurements
    Miljkovic, Nadica
    Bjelica, Milan
    [J]. 2018 ZOOMING INNOVATION IN CONSUMER TECHNOLOGIES CONFERENCE (ZINC), 2018, : 47 - 50
  • [30] FPGA-Based Lock-In Amplifier with Sub-ppm Resolution Working up to 6 MHz
    Gervasoni, G.
    Carminati, M.
    Ferrari, G.
    [J]. 23RD IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS CIRCUITS AND SYSTEMS (ICECS 2016), 2016, : 117 - 120