摘要
The purpose of this study was to prospectively evaluate the immediate (5 minutes) and short-term (1 day) reproducibility of the signal-averaged electrocardiogram (SAECG) in patients with coronary artery disease. A total of 59 consecutive patients with coronary artery disease (50 male, 9 female, mean age 59 +/- 13 years) were included, Analysis was performed using a commercially available system with high-pass filters of 25, 40, and 80 Hz without any change in electrode position. The following time-domain parameters were measured: (1) total filtered QRS duration; (2) duration of high-frequency low-amplitude signals (HFLA); and (3) root-mean-square voltage of She terminal 40 ms of the QRS complex (RMS40). Correlation between pairs of measurements was excellent, ranging from 0.91-0.99 for QRS and HFLA duration, and from 0.83-0.98 for RMS40 value. However, the range of differences was wide for all parameters, especially at 25 and 80 Hz, revealing marked individual variations in selected cases. The immediate reproducibility of an initially normal SAECG was 95% at 25 Hz, 100% at 40 Hz, and 81% at 80 Iii; figures for an initially abnormal SAECG were 89%, 91%, and 93%, respectively, and the coefficient of agreement kappa was highest at 40 Hz than at 25 or 80 Hz. Discordant results were most frequently observed in patients with borderline values, or in cases with nonsimilar residual noise levels. In conclusion the immediate and day-to-day reproducibility of the SAECG is excellent in patients with chronic stable coronary artery disease. However, individual variations are observed in selected cases, leading to modification in interpretation of the result. For this reason, individual reproducibility should be considered before evaluating the effect of any therapeutic intervention on the SAECG, especially in patients with borderline values of the quantitative parameters of the SAECG.
引用
收藏
页码:443 / 454
页数:12
相关论文
共 50 条
  • [31] PROSPECTIVE COMPARISON OF IMMEDIATE VERSUS DAY-TO-DAY REPRODUCIBILITY OF VENTRICULAR-TACHYCARDIA INDUCTION
    COOPER, MJ
    KOO, CC
    SKINNER, MP
    HUNT, LJ
    UTHER, JB
    ROSS, DL
    CIRCULATION, 1987, 76 (04) : 33 - 33
  • [32] DAY-TO-DAY VARIATION OF FRANK ELECTROCARDIOGRAM AND VECTORCARDIOGRAM IN HEART-DISEASE
    KINI, PM
    GINEFRA, P
    PIPBERGER, HV
    AMERICAN HEART JOURNAL, 1974, 88 (06) : 698 - 704
  • [33] DAY-TO-DAY REPRODUCIBILITY OF ANTIARRHYTHMIC DRUG TRIALS USING PROGRAMMED EXTRASTIMULUS TECHNIQUES FOR VENTRICULAR TACHYARRHYTHMIAS ASSOCIATED WITH CORONARY-ARTERY DISEASE
    KUDENCHUK, PJ
    KRON, J
    WALANCE, CG
    CUTLER, JE
    GRIFFITH, KK
    MCANULTY, JH
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (07): : 725 - 730
  • [34] Day-to-day reproducibility of mental stress-induced abnormal left ventricular function response in patients with coronary artery disease and its relationship to autonomic activation
    Diwakar Jain
    Tammy Joska
    Forrester A Lee
    Matthew Burg
    Rachel Lampert
    Barry L Zaret
    Journal of Nuclear Cardiology, 2001, 8 : 347 - 355
  • [35] Day-to-day reproducibility of mental stress-induced abnormal left ventricular function response in patients with coronary artery disease and its relationship to autonomic activation
    Jain, D
    Joska, T
    Lee, FA
    Burg, M
    Lampert, R
    Zaret, BL
    JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (03) : 347 - 355
  • [36] SHORT-TERM EFFECT OF CORONARY-ARTERY BYPASS-GRAFTING ON THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    BORBOLA, J
    SERRY, C
    GOLDIN, M
    DENES, P
    AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (13): : 1001 - 1005
  • [37] QT dispersion and signal-averaged electrocardiogram in hemodialysis and CAPD patients
    Yildiz, A
    Akkaya, V
    Sahin, S
    Tükek, T
    Besler, M
    Bozfakioglu, S
    Korkut, F
    PERITONEAL DIALYSIS INTERNATIONAL, 2001, 21 (02): : 186 - 192
  • [38] ABNORMAL SIGNAL-AVERAGED ELECTROCARDIOGRAM IN PATIENTS WITH DUCHENNE MUSCULAR-DYSTROPHY - COMPARISON OF TIME AND FREQUENCY-DOMAIN ANALYSES FROM THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    KUBO, M
    MATSUOKA, S
    HAYABUCHI, Y
    AKITA, H
    MATSUKA, Y
    KURODA, Y
    CLINICAL CARDIOLOGY, 1993, 16 (10) : 723 - 728
  • [39] P-wave signal-averaged electrocardiogram predicts atrial fibrillation after coronary artery bypass grafting
    Caravelli, P
    De Carlo, M
    Musumeci, G
    Tartarini, G
    Gherarducci, G
    Bortolotti, U
    Mariani, MA
    Mariani, M
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2002, 7 (03) : 198 - 203
  • [40] ABNORMAL SIGNAL-AVERAGED ELECTROCARDIOGRAM IN PATIENTS WITH IDIOPATHIC VENTRICULAR-FIBRILLATION
    DANIELS, MCG
    PARLANGELI, R
    SIPPENSGROENEWEGEN, A
    HAUER, RNW
    DEMEDINA, EOR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A460 - A460