Immediate and day-to-day reproducibility of the signal-averaged electrocardiogram in patients with coronary artery disease

被引:1
|
作者
Paquay, JL
Zimmermann, M
Mermillod, B
Adamec, R
机构
[1] UNIV HOSP GENEVA,CTR CARDIOL,CH-1211 GENEVA 14,SWITZERLAND
[2] UNIV HOSP GENEVA,CTR INFORMAT HOSP,CH-1211 GENEVA 14,SWITZERLAND
来源
关键词
signal-averaging; late potentials;
D O I
10.1111/j.1540-8159.1996.tb06515.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to prospectively evaluate the immediate (5 minutes) and short-term (1 day) reproducibility of the signal-averaged electrocardiogram (SAECG) in patients with coronary artery disease. A total of 59 consecutive patients with coronary artery disease (50 male, 9 female, mean age 59 +/- 13 years) were included, Analysis was performed using a commercially available system with high-pass filters of 25, 40, and 80 Hz without any change in electrode position. The following time-domain parameters were measured: (1) total filtered QRS duration; (2) duration of high-frequency low-amplitude signals (HFLA); and (3) root-mean-square voltage of She terminal 40 ms of the QRS complex (RMS40). Correlation between pairs of measurements was excellent, ranging from 0.91-0.99 for QRS and HFLA duration, and from 0.83-0.98 for RMS40 value. However, the range of differences was wide for all parameters, especially at 25 and 80 Hz, revealing marked individual variations in selected cases. The immediate reproducibility of an initially normal SAECG was 95% at 25 Hz, 100% at 40 Hz, and 81% at 80 Iii; figures for an initially abnormal SAECG were 89%, 91%, and 93%, respectively, and the coefficient of agreement kappa was highest at 40 Hz than at 25 or 80 Hz. Discordant results were most frequently observed in patients with borderline values, or in cases with nonsimilar residual noise levels. In conclusion the immediate and day-to-day reproducibility of the SAECG is excellent in patients with chronic stable coronary artery disease. However, individual variations are observed in selected cases, leading to modification in interpretation of the result. For this reason, individual reproducibility should be considered before evaluating the effect of any therapeutic intervention on the SAECG, especially in patients with borderline values of the quantitative parameters of the SAECG.
引用
收藏
页码:443 / 454
页数:12
相关论文
共 50 条
  • [21] Analysis of the p wave in the signal-averaged electrocardiogram: Normal values and reproducibility
    Hofmann, M
    GoedelMeinen, L
    Beckhoff, A
    Rehbach, K
    Schomig, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1928 - 1932
  • [22] Effects of Amiodarone on the P-wave triggered signal-averaged electrocardiogram in patients with paroxysmal atrial fibrillation and coronary artery disease
    Banasiak, W
    Telichowski, A
    Anker, SD
    Fuglewicz, A
    Kalka, D
    Molenda, W
    Reczuch, K
    Adamus, J
    Coats, AJS
    Ponikowski, P
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (01): : 112 - +
  • [23] DAY-TO-DAY VARIABILITY OF MYOCARDIAL ISCHEMIC EPISODES IN CORONARY-ARTERY DISEASE
    TZIVONI, D
    GAVISH, A
    BENHORIN, J
    BANAI, S
    KEREN, A
    STERN, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (13): : 1003 - 1005
  • [24] Prognostic value of signal-averaged electrocardiogram in Chagas disease
    Ribeiro, Antonio Luiz Pinho
    Cavalvanti, Paulo Sergio
    Lombardi, Federico
    Do Carmo Pereira Nunes, Maria
    Barros, Marcio Vinicius Lins
    Da Costa Rocha, Manoel Otavio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (05) : 502 - 509
  • [25] LACK OF CORRELATION BETWEEN THE SIGNAL-AVERAGED ELECTROCARDIOGRAM AND REGIONAL WALL MOTION ABNORMALITIES IN CORONARY-ARTERY DISEASE
    WOELFEL, A
    WEAVER, DE
    JENKINS, M
    WOELFEL, LP
    HERBST, MC
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (04): : 415 - 417
  • [26] UTILITY OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM TO IDENTIFY CIRCUMFLEX CORONARY INFARCTIONS
    DOEVENDANS, P
    VANDENDOOL, A
    VANDEBIJL, B
    BAR, FW
    WELLENS, HJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A196 - A196
  • [27] Short-, mid-, and long-term reproducibility of the atrial signal-averaged electrocardiogram in healthy subjects: Comparison with the conventional ventricular signal-averaged electrocardiogram
    Savelieva, I
    Aytemir, K
    Hnatkova, K
    Camm, AJ
    Malik, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (01): : 122 - 127
  • [28] Relation between myocardial viability and abnormalities on the signal-averaged electrocardiogram in patients with low (<40%) ejection fraction and coronary artery disease
    Ragosta, M
    Pagley, PR
    DiMarco, JP
    Beller, GA
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (04): : 405 - 410
  • [29] CORRELATION BETWEEN THE SIGNAL-AVERAGED ELECTROCARDIOGRAM AND ELECTROPHYSIOLOGIC STUDY FINDINGS IN PATIENTS WITH CORONARY-ARTERY DISEASE AND SUSTAINED VENTRICULAR-TACHYCARDIA
    BORBOLA, J
    EZRI, MD
    DENES, P
    AMERICAN HEART JOURNAL, 1988, 115 (04) : 816 - 824
  • [30] PROSPECTIVE COMPARISON OF IMMEDIATE VERSUS DAY-TO-DAY REPRODUCIBILITY OF VENTRICULAR-TACHYCARDIA INDUCTION
    COOPER, MJ
    KOO, CC
    SKINNER, MP
    HUNT, LJ
    UTHER, JB
    ROSS, DL